Amperometric glutamate biosensor based on poly(o-phenylenediamine) film electrogenerated onto modified carbon paste electrodes

被引:52
|
作者
Alvarez-Crespo, SL [1 ]
Lobo-Castanon, MJ [1 ]
Miranda-Ordieres, AJ [1 ]
Tunon-Blanco, P [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Asturias, Spain
来源
BIOSENSORS & BIOELECTRONICS | 1997年 / 12卷 / 08期
关键词
glutamate; poly(O-phenylenediamine) amperometric biosensor; carbon paste;
D O I
10.1016/S0956-5663(97)00041-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A glutamate biosensor was developed by electropolymerizing o-phenylenediamine on a dehydrogenase-NAD(+) modified carbon paste electrode. The amperometric response to glutamate was obtained by means of the electrocatalytic oxidation of the enzymatically produced NADH, at an applied potential close to OV (Ag/AgCl). After optimizing carbon paste composition, polymer thickness and operating variables, a linear amperometric response to glutamate was obtained within the concentration range 5.0 x 10(-6)-7.8 x 10(-5) M with a detection limit of 3.8 x 10(-6) M. The biosensor was applied to the determination of glutamate in chicken bouillon cubes. Good accuracy was found with respect to a reference enzymatic spectrophotometric method. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:739 / 747
页数:9
相关论文
共 50 条
  • [31] MEDIATED AMPEROMETRIC BIOSENSOR FOR HYPOXANTHINE BASED ON A HYDROXYMETHYLFERROCENE-MODIFIED CARBON PASTE ELECTRODE
    OKUMA, H
    TAKAHASHI, H
    SEKIMUKAI, S
    ANALYTICA CHIMICA ACTA, 1991, 244 (02) : 161 - 164
  • [32] Pyranose oxidase biosensor based on carbon nanotube (CNT)-modified carbon paste electrodes
    Odaci, Dilek
    Telefoncu, Azmi
    Timur, Suna
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 132 (01) : 159 - 165
  • [33] Effects of polymerization potential on the permselectivity of poly(o-phenylenediamine) coatings deposited on Pt-Ir electrodes for biosensor applications
    Rothwell, Sharon A.
    McMahon, Colm P.
    O'Neill, Robert D.
    ELECTROCHIMICA ACTA, 2010, 55 (03) : 1051 - 1060
  • [34] A new amperometric biosensor for hydrogen peroxide determination based on HRP-nanogold-PTH-nanogold-modified carbon paste electrodes
    Fuchang Wang
    Ruo Yuan
    Yaqin Chai
    European Food Research and Technology, 2007, 225 : 95 - 104
  • [35] A new amperometric biosensor for hydrogen peroxide determination based on HRP-nanogold-PTH-nanogold-modified carbon paste electrodes
    Wang, Fuchang
    Yuan, Ruo
    Chai, Yaqin
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2007, 225 (01) : 95 - 104
  • [36] Amperometric sensor for hydrogen peroxide, based on Cu2O or CuO modified carbon paste electrodes
    Rasa Garjonyte
    A. Malinauskas
    Fresenius' Journal of Analytical Chemistry, 1998, 360 : 122 - 123
  • [37] Amperometric sensor for hydrogen peroxide, based on Cu2O or CuO modified carbon paste electrodes
    Garjonyte, R
    Malinauskas, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (01): : 122 - 123
  • [38] Glucose biosensor based on glucose oxidase immobilized in electropolymerized polypyrrole and poly(o-phenylenediamine) films on a Prussian Blue-modified electrode
    Garjonyte, R
    Malinauskas, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (1-2) : 122 - 128
  • [39] Development of amperometric biosensor in modified carbon paste with enzymatic preparation based on lactase immobilized on carbon nanotubes
    de Brito, Aila Riany
    Reis, Nadabe dos Santos
    Oliveira, Polyany Cabral
    Boas Rezende, Denilde Vilas
    Monteiro, Gabriel Pereira
    Soares, Gleydison Amarante
    de Jesus, Rodrigo Sa
    Santos, Antonio Santana
    Salay, Luiz Carlos
    de Oliveira, Julieta Rangel
    Franco, Marcelo
    JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 2020, 57 (04): : 1342 - 1350
  • [40] Development and applications of a bienzymatic amperometric glycerol biosensor based on a poly(neutral red) modified carbon film electrode
    Ghica, Mariana Emilia
    Brett, Christopher M. A.
    ANALYTICAL LETTERS, 2006, 39 (08) : 1527 - 1542