Amperometric glutamate biosensor based on poly(o-phenylenediamine) film electrogenerated onto modified carbon paste electrodes

被引:52
|
作者
Alvarez-Crespo, SL [1 ]
Lobo-Castanon, MJ [1 ]
Miranda-Ordieres, AJ [1 ]
Tunon-Blanco, P [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Asturias, Spain
来源
BIOSENSORS & BIOELECTRONICS | 1997年 / 12卷 / 08期
关键词
glutamate; poly(O-phenylenediamine) amperometric biosensor; carbon paste;
D O I
10.1016/S0956-5663(97)00041-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A glutamate biosensor was developed by electropolymerizing o-phenylenediamine on a dehydrogenase-NAD(+) modified carbon paste electrode. The amperometric response to glutamate was obtained by means of the electrocatalytic oxidation of the enzymatically produced NADH, at an applied potential close to OV (Ag/AgCl). After optimizing carbon paste composition, polymer thickness and operating variables, a linear amperometric response to glutamate was obtained within the concentration range 5.0 x 10(-6)-7.8 x 10(-5) M with a detection limit of 3.8 x 10(-6) M. The biosensor was applied to the determination of glutamate in chicken bouillon cubes. Good accuracy was found with respect to a reference enzymatic spectrophotometric method. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:739 / 747
页数:9
相关论文
共 50 条
  • [1] Amperometric detection of ethanol with poly-(o-phenylenediamine)-modified enzyme electrodes
    Castanon, MJL
    Ordieres, AJM
    Blanco, PT
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (06): : 511 - 520
  • [2] Electrocatalytic detection of nicotinamide coenzymes by poly(o-aminophenol)- and poly(o-phenylenediamine)-modified carbon paste electrodes
    Lobo, MJ
    Miranda, AJ
    LopezFonseca, JM
    Tunon, P
    ANALYTICA CHIMICA ACTA, 1996, 325 (1-2) : 33 - 42
  • [4] A bienzyme-poly-(o-phenylenediamine)-modified carbon paste electrode for the amperometric detection of L-lactate
    LoboCastanon, MJ
    MirandaOrdieres, AJ
    TunonBlanco, P
    ANALYTICA CHIMICA ACTA, 1997, 346 (02) : 165 - 174
  • [5] Amperometric glucose biosensor based on glucose oxidase immobilized in poly(o-phenylenediamine) layer
    Garjonyte, R
    Malinauskas, A
    SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) : 85 - 92
  • [6] Amperometric glucose biosensor based on glucose oxidase immobilized in poly(o-phenylenediamine) layer
    Garjonyte, R.
    Malinauskas, A.
    Sensors and Actuators, B: Chemical, 1999, 56 (01): : 85 - 92
  • [7] A novel amperometric adenosine triphosphate biosensor by immobilizing graphene/dual-labeled aptamers complex onto poly(o-phenylenediamine) modified electrode
    Wen, Wei
    Bao, Ting
    Yang, Jing
    Zhang, Ming-Zhen
    Chen, Wei
    Xiong, Hua-Yu
    Zhang, Xiu-Hua
    Zhao, Yuan-Di
    Wang, Sheng-Fu
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 695 - 702
  • [8] Electrocatalytic oxidation of methanol on electrodes modified by platinum microparticles dispersed into poly(o-phenylenediamine) film
    Golabi, SM
    Nozad, A
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 521 (1-2) : 161 - 167
  • [9] Electrochemical Investigation of Catechol and Hydroquinone at Poly(o-Phenylenediamine) Modified Carbon Paste Electrode: A Voltammetric Study
    Chetankumar, K.
    Swamy, B. E. Kumara
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (12): : 1638 - 1650
  • [10] An amperometric sensor based on Prussian blue and poly(o-phenylenediamine) modified glassy carbon electrode for the determination of hydrogen peroxide in beverages
    Ping, Jianfeng
    Wu, Jian
    Fan, Kai
    Ying, Yibin
    FOOD CHEMISTRY, 2011, 126 (04) : 2005 - 2009