Analysis of Power Transformer Magnetizing Inrush and Overexcitation Conditions in Case of Overvoltages due to Line-to-Ground Fault

被引:0
|
作者
Solak, Krzysztof [1 ]
Rebizant, Waldemar [1 ]
Mieske, Frank [2 ]
Schneider, Sebastian [2 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Elect Engn, Wroclaw, Poland
[2] Siemens AG, Berlin, Germany
关键词
power transformer; differential relay; magnetizing inrush; overexcitation; transient simulation; harmonic blocking;
D O I
10.1109/MEPS46793.2019.9395009
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, simulation of power transformer operation during external phase-to-ground faults are presented, with special attention paid to the overvoltage, magnetizing inrush and overexcitation conditions due to such faults. The motivation for conducted studies were recorded cases of maloperation of transformer differential protection during external faults. The paper starts with initial analysis of the recorded cases. Then developed model of the network with protected transformer is described and verified by simulations with MATLAB/Simulink software. Theoretical and simulation investigations lead to observations related to the level of overvoltage and harmonic content in the currents during considered faults, as well as reasons of protection wrong operation. Discussion about the possibility of harmonic blocking application concludes the paper.
引用
收藏
页数:6
相关论文
共 35 条
  • [21] THE ANALYSIS AND PREDICTION OF HARMONIC RESONANT OVERVOLTAGES RESULTING FROM LINE DROPPING AND FAULT CLEARING TRANSFORMER-TERMINATED EHV LINES
    BOOTH, WH
    WASILOWSKI, RB
    NIEBUHR, WD
    ROCAMORA, RG
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (02): : 729 - 736
  • [22] Application of signal processing and analysis in detecting single line-to-ground (SLG) fault location in high-impedance grounded distribution network
    Li, Yajie
    Meng, Xiaoli
    Song, Xiaohui
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (02) : 382 - 389
  • [23] Analysis of overvoltages in overhead ground wires of extra high voltage (EHV) power transmission line under single-phase-to-ground faults
    Dudurych, I
    Rosolowski, E
    ELECTRIC POWER SYSTEMS RESEARCH, 2000, 53 (02) : 105 - 111
  • [24] Analytical Analysis and Case Study of Transient Behavior of Inrush Current in Power Transformer for Designing of Efficient Circuit Breakers
    Harmanpreet
    Singh, Sukhwinder
    Kumar, Ashok
    Kaur, Parneet
    INTERNATIONAL CONFERENCE ON METHODS AND MODELS IN SCIENCE AND TECHNOLOGY (ICM2ST-10), 2010, 1324 : 135 - +
  • [25] Statistical analysis of the double line-to-ground short-circuit current in MV urban network for the power cable metallic screen rating
    Korab, Roman
    Siwy, Edward
    2006 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS, VOLS 1 AND 2, 2006, : 973 - 978
  • [26] DISTRIBUTION LINE MODEL FOR SINGLE-PHASE-TO-GROUND FAULT ANALYSIS IN DISTRIBUTION POWER SYSTEMS
    Tang, Jinrui
    Wang, Jiaqi
    Yang, Chen
    Liu, Bowen
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2018, 80 (04): : 149 - 160
  • [27] Effect Analysis of Protection Relay Element in the Case of Ground Fault in Microgrid Power System
    Chae D.-J.
    Kang H.-G.
    Lim S.-T.
    Oh C.-H.
    Lee K.-Y.
    Transactions of the Korean Institute of Electrical Engineers, 2023, 72 (03): : 467 - 474
  • [28] Analysis on the protective coordination on neutral line of main transformer in power distribution substation with superconducting fault current limiter
    Kim, Jin-Seok
    Lim, Sung-Hun
    Moon, Jong-Fil
    Kim, Jae-Chul
    Hyun, Ok-Bae
    Transactions of the Korean Institute of Electrical Engineers, 2009, 58 (11): : 2089 - 2094
  • [29] A case-based reasoning approach to power transformer fault diagnosis using dissolved gas analysis data
    Qian, Z.
    Gao, W. S.
    Wang, F.
    Yan, Z.
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2009, 19 (03): : 518 - 530
  • [30] A Comparative Study of Ground Fault Analysis for a Practical Case of a Transmission Line Equipped with Different Series FACTS Devices
    Zellagui, Mohamed
    Hassan, Heba A.
    Chaghi, Abdelaziz
    Ghorbani, Amir
    AUTOMATIKA, 2015, 56 (03) : 262 - 274