Edge Vascular Response After Polymer-Free vs. Polymer-Based Paclitaxel-Eluting Stent Implantation - Serial Intravascular Ultrasound Study From the Late Incomplete Stent Apposition Evaluation (LISA) Trial

被引:1
|
作者
Otsuki, Shuji [1 ]
Shiratori, Yoshitaka [1 ]
Brugaletta, Salvatore [1 ]
Cola, Clarissa [2 ]
Garcia del Blanco, Bruno [3 ]
Ruiz-Salmeron, Rafael [4 ]
Francisco Diaz, Jose [5 ]
Pinar, Eduardo [6 ]
Marti, Vicens [2 ]
Garcia-Picart, Juan [2 ]
Martin-Yuste, Victoria [1 ]
Sabate, Manel [1 ]
机构
[1] Univ Barcelona, Dept Cardiol, Hosp Clin, IDIBAPS, Barcelona, Spain
[2] St Pau Hosp, Dept Cardiol, Barcelona, Spain
[3] Vall dHebron Hosp, Dept Cardiol, Barcelona, Spain
[4] Virgen de Macarena Hosp, Dept Cardiol, Seville, Spain
[5] Juan Ramon Jimenez Hosp, Dept Cardiol, Huelva, Spain
[6] Virgen de la Arrixaca Hosp, Dept Cardiol, Murcia, Spain
关键词
Drug-eluting stent; Edge vascular response; Intravascular ultrasound; Polymer-based paclitaxel-eluting stent; Polymer-free paclitaxel-eluting stent; CORONARY-ARTERY LESIONS; RANDOMIZED-TRIAL; CLINICAL-TRIAL; DIABETIC-PATIENTS; SLOW-RELEASE; FOLLOW-UP; TAXUS-IV; REVASCULARIZATION; HYPERPLASIA; IMPACT;
D O I
10.1253/circj.CJ-14-0345
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). Methods and Results: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1: 1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis. Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02 +/- 3.06 mm(2) to 8.47 +/- 3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39 +/- 2.73 mm(2) to 4.78 +/- 2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). Conclusions: PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.
引用
收藏
页码:2657 / 2664
页数:8
相关论文
共 50 条
  • [41] First five-year clinical follow-up from a randomized trial of a polymer-based, paclitaxel-eluting stent: TAXUS I
    Grube, Eberhard
    Silber, Sigmund
    Hauptman, Karl E.
    Koglin, Joerg
    Russell, Mary E.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 141M - 141M
  • [42] Serial Evaluation of Vascular Response After Implantation of a New Sirolimus-Eluting Stent With Bioabsorbable Polymer (MISTENT): An Optical Coherence Tomography and Histopathological Study
    Attizzani, Guilherme F.
    Bezerra, Hiram G.
    Chamie, Daniel
    Fujino, Yusuke
    Spognardi, Anna-Maria
    Stanley, James R. L.
    Yamamoto, Hirosada
    Mehanna, Emile
    Wang, Wei
    Carlyle, Wenda C.
    McClain, James B.
    Costa, Marco A.
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (11): : 560 - 568
  • [43] Vascular Responses at Proximal and Distal Edges of Sirolimus-Eluting or Paclitaxel-Eluting Stent in Diabetic Patients. A Randomized Serial Intravascular Ultrasound Analysis from the DiabeDES II Trial
    Jensen, Lisette Okkels
    Maeng, Michael
    Mintz, Gary S.
    Christiansen, Evald Hoej
    Hansen, Knud N.
    Galloe, Anders
    Kelbaek, Henning
    Lassen, Jens F.
    Thuesen, Leif
    Thayssen, Per
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 205I - 206I
  • [44] Two-year intravascular ultrasound follow-up after implantation of non-polymeric paclitaxel-coated stents: A serial volumetric intravascular ultrasound analysis from the Asian paclitaxel-eluting stent clinical trial (ASPECT)
    Park, DW
    Hong, MK
    Jeong, YH
    Hwang, ES
    Lee, SW
    Lee, BK
    Kim, YH
    Han, KH
    Lee, CW
    Kim, JJ
    Park, SW
    Park, SJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 189A - 189A
  • [45] Four-Month QCA and IVUS Results of the PAX-A Trial: A Randomized Comparison with Serial QCA and IVUS of the Novel Polymer-Free Amazonia Pax® Paclitaxel-Eluting Stent System versus the Taxus® Liberte Stent
    Costa, Jose de Ribamar
    Abizaid, Alexandre
    Costa, Ricardo
    Feres, Fausto
    Chamie, Daniel
    Staico, Rodolfo
    Siqueira, Dimytri
    Maldonado, Galo
    Tanajura, Luiz Fernando
    Sousa, Amanda
    Sousa, J. Eduardo
    CIRCULATION, 2010, 122 (21)
  • [46] Durability of the polymer-based, paclitaxel-eluting TAXUS stent in key patient subsets: Two-year results from the TAXUS-IV trial
    Ellis, S
    Stone, GW
    Cox, DA
    Hermiller, J
    O'Shaughnessey, CD
    Mann, JT
    Turco, M
    Caputo, R
    Bergin, PJ
    Greenberg, J
    Raizner, A
    Popma, JJ
    Russell, ME
    Russell, ME
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 49A - 49A
  • [47] Impact of Positive Peristent Vascular Remodeling After Sirolimus-eluting and Paclitaxel-eluting Stent Implantation on 5-year Clinical Outcomes: Intravascular Ultrasound Analysis From the POET, a Multicenter, Randomized Trial
    Kang, Ki-Woon
    Ko, Young-Guk
    Shin, Dong-Ho
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B22 - B22
  • [48] Comparison of ticlopidine vs. clopidogrel in addition to aspirin after paclitaxel-eluting stent implantation:: Insights from the TRUE (Taxus™ in Real-life Usage Evaluation) Study
    Biondi-Zoccai, GGL
    Agostoni, P
    Sangiorgi, GM
    Iakovou, I
    Antoniucci, D
    Grube, E
    Tamburino, C
    Di Mario, C
    Reimers, B
    Michev, L
    Goktekin, O
    Airoldi, F
    Chieffo, A
    Cosgrave, J
    Tassanawiwat, W
    Colombo, A
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 108 (03) : 406 - 407
  • [49] IS THERE A DIFFERENCE IN VASCULAR RESPONSE BETWEEN BIODEGRADABLE POLYMER-BASED VERSUS NONPOLYMER-BASED BIOLIMUS-ELUTING STENT? SHORT-TERM INTRAVASCULAR ULTRASOUND RESULTS FROM STEALTH AND BIOFREEDOM TRIAL
    Kim, Byoung-Keuk
    Otake, Hiromasa
    Waseda, Katsuhisa
    Nakatani, Daisaku
    Sakata, Kenji
    Shimada, Yoshihisa
    Koizumi, Tomomi
    Honda, Yasuhiro
    Grube, Eberhard
    Fitzgerald, Peter J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [50] VESSEL RESPONSE TO THE NOVEL POLYMER-FREE BIOFREEDOM STENT VERSUS CONVENTIONAL DURABLE POLYMER COATING STENT: SHORT- AND MID-TERM INTRAVASCULAR ULTRASOUND RESULTS FROM THE BIOFREEDOM FIRST-IN-MAN TRIAL
    Sakata, Kenji
    Kim, Byeong-Keuk
    Otake, Hiromasa
    Waseda, Katsuhisa
    Schuler, Gerhard C.
    Hauptmann, Karl E.
    Schofer, Joachim
    Yock, Paul G.
    Honda, Yasuhiro
    Grube, Eberhard
    Fitzgerald, Peter J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1758 - E1758