Validation of the CT-MRI image registration with a dedicated phantom

被引:1
|
作者
Spampinato, Sofia [1 ,2 ,3 ]
Gueli, Anna Maria [1 ,2 ,4 ]
Raffaele, Luigi [3 ,4 ]
Stancampiano, Concetta [3 ,4 ]
Ettorre, Giovanni Carlo [3 ]
机构
[1] Univ Catania, Dipartimento Fis & Astron, Labs PHys Dating Diagnost Dosimetry Res & Applica, I-95123 Catania, Italy
[2] INFN Catania, I-95123 Catania, Italy
[3] Azienda Osped Univ Policlin Catania, I-95123 Catania, Italy
[4] Univ Catania, Scuola Specializzaz Fis Med, Dipartimento Specialita Med Chirurg, I-95123 Catania, Italy
来源
RADIOLOGIA MEDICA | 2014年 / 119卷 / 12期
关键词
Radiotherapy treatment planning; Computed tomography; Magnetic resonance imaging; Image registration; Phantom; Quality assurance; QUALITY-ASSURANCE; ACCURACY EVALUATION; PROSTATE; FUSION; LOCALIZATION; SOFTWARE; SCANS;
D O I
10.1007/s11547-014-0392-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The present study was aimed at verifying the automatic registration of the Focal (Elekta) platform with a dedicated phantom. A phantom that simulates the pelvis region in a stylised way and finalised to the registration of computed tomography-magnetic resonance images was designed and realised. After acquiring the two sets of images, the registration was performed both in automatic and manual mode to verify whether they were comparable. To test the repeatability of the automatic registration, some known rigid transformations were imposed to the original images. If the registration method works correctly, parameters which bring the images into alignment must always be the same. Automatic registration performed by the software did not prove satisfactory, whereas if a specific tool [volume of interest (VOI) tool] allowing the calculation to be limited to the landmark region was used, the registration parameters were comparable with those of the manual registration. Regarding the repeatability of the automatic registration, the software brought the images in the correct alignment performing translations and rotations along the longitudinal axis up to 40A degrees, while it was not satisfactory for rotations along the transverse axes. The experimental results showed that in clinical application automatic registration is reliable if the VOI tool that includes visible landmarks in both studies is used. However, because the algorithm did not prove sensitive to rotations along the transverse axes, the position of the patient during the examinations plays a crucial role.
引用
收藏
页码:942 / 950
页数:9
相关论文
共 50 条
  • [31] Comparison of manual vs. automated multimodality (CT-MRI) image fusion for brain tumors
    Sarkar, A
    Santiago, R
    Smith, R
    Kassaee, A
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1505 - 1505
  • [32] Dedicated registration for DCE MRI mammography
    Renisch, Steffen
    Bulow, Thomas
    Carlsen, Ingwer C.
    Franz, Astrid
    [J]. MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [33] Validation of Accuracy in Deformable Image Registration by Use of Three-Dimensional Phantom
    Kobayashi, M.
    Hayashi, N.
    Egami, K.
    Yasui, K.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E228 - E228
  • [34] Multisite multivendor validation of a quantitative MRI and CT compatible fat phantom
    Zhao, Ruiyang
    Hernando, Diego
    Harris, David T.
    Hinshaw, Louis A.
    Li, Ke
    Ananthakrishnan, Lakshmi
    Bashir, Mustafa R.
    Duan, Xinhui
    Ghasabeh, Mounes Aliyari
    Kamel, Ihab R.
    Lowry, Carolyn
    Mahesh, Mahadevappa
    Marin, Daniele
    Miller, Jessica
    Pickhardt, Perry J.
    Shaffer, Jean
    Yokoo, Takeshi
    Brittain, Jean H.
    Reeder, Scott B.
    [J]. MEDICAL PHYSICS, 2021, 48 (08) : 4375 - 4386
  • [35] 3D Phantom insert for verification of image registration for SPECT/CT and PET/CT
    Dyer, Stephen
    Levy, Joshua
    Goodenough, David
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [36] Urethrogram combined CT-MRI image fusion to determine apex in IMRT for localized prostatic cancer
    Nishiyama, K.
    Toyofuku, T.
    Ikemoto, S. I.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S833 - S833
  • [37] Use of a Rigidity Penalty to Improve CT to MRI Image Registration
    Boehnke, E.
    Santhanam, A.
    Gao, C.
    Sheng, K.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E686 - E686
  • [38] Image Registration of An EMT-Enabled Afterloader and CT Scan: A Phantom Study
    Gomez-Sarmiento, I.
    Tho, D.
    de Jager, W.
    Laurendeau, D.
    Beaulieu, L.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E241 - E241
  • [39] Metal artifacts with dental implants: Evaluation using a dedicated CT/MR oral phantom with registration of the CT and MR images
    Lee, Min-Young
    Song, Kyu-Ho
    Lee, Jeong-Woo
    Choe, Bo-Young
    Suh, Tae Suk
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [40] Metal artifacts with dental implants: Evaluation using a dedicated CT/MR oral phantom with registration of the CT and MR images
    Min-Young Lee
    Kyu-Ho Song
    Jeong-Woo Lee
    Bo-Young Choe
    Tae Suk Suh
    [J]. Scientific Reports, 9