Low temperature Thomson scattering on MAST-U

被引:10
|
作者
Clark, J. G. [1 ,2 ]
Bowden, M. D. [1 ]
Scannell, R. [2 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
[2] UKAEA CCFE, Culham Sci Ctr, Abingdon OX14 3DB, Oxon, England
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2021年 / 92卷 / 04期
基金
英国工程与自然科学研究理事会;
关键词
All Open Access; Hybrid Gold;
D O I
10.1063/5.0043813
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new divertor Thomson scattering system has been developed for the MAST-U tokamak. The diagnostic will produce electron density and temperature profiles along the Super-X strike leg. The existing polychromator design has been adapted for low temperature measurements. A new 1061 nm channel with 2 nm bandwidth has been added to enable measurements down below the previous similar to 5 eV limit on the core system. The optical filters used in the system have OD6 light rejection alongside a 1064.1 nm laser line filter to reduce stray light in the digitized channels. A new averaging technique has been applied to the scattered signal traces to improve the core Thomson data in the scrape-off layer. The technique reduces the systematic noise level in this region. This leads to a reduction in the error values for electron density and temperature measurements and, in particular, the digitizer noise. The technique has been applied to produce a radial profile for a number of L-mode MAST discharges down to very low densities of similar to 1 x 10(18) m(-3).
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Combined visible and infrared Thomson scattering on the MAST experiment
    Walsh, MJ
    Arends, ER
    Carolan, PG
    Dunstan, MR
    Forrest, MJ
    Nielsen, SK
    O'Gorman, R
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1663 - 1666
  • [32] Real Time Operation of MAST Thomson Scattering Diagnostic
    Shibaev, Sergei
    Naylor, Graham
    Scannell, Rory
    McArdle, Graham J.
    Walsh, Michael J.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (04) : 1516 - 1521
  • [33] Low-cost multichannel Thomson scattering system for CDX-U
    Munsat, T.
    LeBlanc, B.
    [J]. Review of Scientific Instruments, 1999, 70 (1 pt 2): : 755 - 758
  • [34] MAST YAG Thomson scattering upgrade alignment system
    Figueiredo, J.
    Naylor, G.
    Walsh, M.
    Dunstan, M.
    Scannell, R.
    Serra, F.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [35] Development and calibration of a multi-delay coherence imaging diagnostic on the MAST-U tokamak
    Doyle, R. S.
    Lonigro, N.
    Allcock, J. S.
    Silburn, S. A.
    Turner, M. M.
    Feng, X.
    Leggate, H.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (05):
  • [36] First measurements of energetic protons in Mega Amp Spherical Tokamak Upgrade (MAST-U)
    Aboutaleb, A.
    Allan, S. Y.
    Boeglin, W. U.
    Cecconello, M.
    Jackson, A.
    McClements, K. G.
    Parr, E.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (08):
  • [37] Initial Fulcher band observations from high resolution spectroscopy in the MAST-U divertor
    Osborne, N.
    Verhaegh, K.
    Bowden, M. D.
    Wijkamp, T.
    Lonigro, N.
    Ryan, P.
    Pawelec, E.
    Lipschultz, B.
    Soukhanovskii, V
    van den Biggelaar, T.
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 2024, 66 (02)
  • [38] High heat flux engineering for the upgraded neutral beam injection systems of MAST-U
    Dhalla, F.
    Mistry, S.
    Turner, I.
    Barrett, T. R.
    Day, I.
    McAdams, R.
    [J]. FUSION ENGINEERING AND DESIGN, 2015, 96-97 : 458 - 462
  • [39] Simulations of edge localised mode instabilities in MAST-U Super-X tokamak plasmas
    Smith, S. F.
    Pamela, S. J. P.
    Fil, A.
    Hoelzl, M.
    Huijsmans, G. T. A.
    Kirk, A.
    Moulton, D.
    Myatra, O.
    Thornton, A. J.
    Wilson, H. R.
    [J]. NUCLEAR FUSION, 2020, 60 (06)
  • [40] ION AND ELECTRON TEMPERATURE AND DENSITY BY THOMSON SCATTERING WITH A LOW RESOLUTION MONOCHROMETER
    SIEMON, RE
    BENFORD, J
    [J]. PHYSICS OF FLUIDS, 1969, 12 (01) : 249 - &