Reduction in hemoglobin A1c with real-time continuous glucose monitoring: Results from a 12-week observational study

被引:114
|
作者
Bailey, Timothy S.
Zisser, Howard C.
Garg, Satish K.
机构
[1] Univ Colorado Denver, Barbara Davis Ctr Diabet, Aurora, CO 80010 USA
[2] N Cty Endocrine Med Grp, Escondilo, CA USA
[3] Sansum Diabet Res Inst, Santa Barbara, CA USA
关键词
D O I
10.1089/dia.2007.0205
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Real-time continuous glucose monitoring (CGM) was studied in 140 adults with diabetes over a 12-week period of home use. Hemoglobin A(1c) (HbA1c) was measured on day I (baseline) and at weeks 6 and 12. Methods: On day 1, participants received the CGM device (STS (R) System, DexCom, Inc., San Diego, CA) and underwent training on proper use. Insertion of the first sensor was performed under staff supervision. Subjects inserted subsequent sensors on their own. After calibration, the device (a 3-day sensor, receiver, and transmitter) provided users with real-time glucose values updated at 5-min intervals, glucose trend graphs, configurable high/low alerts, and a hypoglycemia alarm (<= 55 mg/dL). Study participants were given supplies sufficient for 3 weeks of device use. Follow-up visits were performed at 3-week intervals for resupply and to download CGM data, with a final visit at the end of week 12. Results: Overall, a reduction in HbA1c of 0.4 +/- 0.05% (least squares mean +/- SE) was observed, P < 0.0001. Significant HbA1c reductions were observed across subgroups of subjects with both type I and 2 diabetes, and those delivering insulin by multiple daily injections and pumps. The largest HbA1c reduction (1.4 +/- 0.4%) was observed in subjects with baseline HbA1c > 9.0%. Increased CGM use was associated with greater reductions in HbAlc. Conclusions: This observational study showed that home use of real-time GCM was safe and well tolerated and associated with a clinically and statistically significant reduction in HbAlc. Large-scale randomized, controlled outcome studies of CGM are indicated.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 50 条
  • [11] HEMOGLOBIN A1C LEVELS AMONG PEOPLE WITH TYPE 1 DIABETES SWITCHING FROM SELF-MONITORING OF BLOOD GLUCOSE TO REAL-TIME CGM USE: A RETROSPECTIVE LONGITUDINAL STUDY
    Noor, N.
    Mann, E.
    Desalvo, D. J.
    Sanchez, J.
    Levy, C.
    Akturk, H. K.
    Alonso, G. Todd
    Ebekozien, O.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A160 - A160
  • [12] Estimation of Hemoglobin A1c from Continuous Glucose Monitoring Data in Individuals with Type 1 Diabetes: Is Time In Range All We Need?
    Fabris, Chiara
    Heinemann, Lutz
    Beck, Roy
    Cobelli, Claudio
    Kovatchev, Boris
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (07) : 501 - 508
  • [13] ESTIMATION OF HEMOGLOBIN A1C FROM CONTINUOUS GLUCOSE MONITORING DATA IN INDIVIDUALS WITH TYPE 1 DIABETES: IS TIME IN RANGE ALL WE NEED?
    Fabris, C.
    Heinemann, L.
    Beck, R.
    Cobelli, C.
    Kovatchev, B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A31 - A32
  • [14] Predictive Factors of the Adherence to Real-Time Continuous Glucose Monitoring Sensors: A Prospective Observational Study (PARCS STUDY)
    Murata, Takashi
    Kuroda, Akio
    Matsuhisa, Munehide
    Toyoda, Masao
    Kimura, Moritsugu
    Hirota, Yushi
    Kato, Ken
    Sawaki, Hideaki
    Tone, Atsuhito
    Kawashima, Satoshi
    Okada, Akira
    Watanabe, Tomokazu
    Nirengi, Shinsuke
    Suganuma, Akiko
    Sakane, Naoki
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (05): : 1084 - 1092
  • [15] CORRELATION BETWEEN FREQUENCY OF FLASH GLUCOSE MONITORING SCANS AND HEMOGLOBIN A1C LEVELS: A REAL LIFE STUDY
    Laurenzi, A.
    Caretto, A.
    Barrasso, M.
    Bolla, A. M.
    Molinari, C.
    Dozio, N.
    Scavini, M.
    Meneghini, E.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A99 - A99
  • [16] Individualized Hemoglobin A1C: A New Glycemic Marker Determined Using Continuous Glucose Monitoring
    Bergenstal, Richard M.
    Dunn, Timothy
    Xu, Yongjin
    Ajjan, Ramzi
    DIABETES, 2019, 68
  • [17] Individualized Hemoglobin A1C: A New Glycemic Marker Determined Using Continuous Glucose Monitoring
    Bergenstal, Richard M.
    Dunn, Timothy
    Xu, Yongjin
    Ajjan, Ramzi
    DIABETES, 2019, 68
  • [18] TIME WITHIN THE DESIRED GLUCOSE RANGE MEASURED BY CONTINUOUS GLUCOSE MONITORING CORRELATE WITH A1C
    Farfel, A.
    Ajzenstejn, M.
    Miller, S.
    Phillip, M.
    Nimri, R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A61 - A61
  • [19] Time in range-A1c hemoglobin relationship in continuous glucose monitoring of type 1 diabetes: a real-world study
    Valenzano, Marina
    Bertolotti, Ivan Cibrario
    Valenzano, Adriano
    Grassi, Giorgio
    BMJ OPEN DIABETES RESEARCH & CARE, 2021, 9 (01)
  • [20] The Effect of Reduced Self-Monitored Blood Glucose Testing After Adoption of Continuous Glucose Monitoring on Hemoglobin A1c and Time in Range
    Puhr, Sarah
    Calhoun, Peter
    Welsh, John B.
    Walker, Tomas C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (08) : 557 - 560