Development of a New Apparatus for Evaluating Flowability of Particle with Poor Flow Behavior

被引:1
|
作者
Yoshida, Mikio [1 ]
Furue, Nanako [1 ]
Oshitani, Jun [1 ]
Goto, Kuniaki [1 ]
机构
[1] Okayama Univ, Grad Sch Nat Sci & Technol, Div Chem & Biol Technol, Kita Ku, Okayama 7008530, Japan
关键词
Poor Powder Flowability; New Apparatus; Drained Angle; Shear Test; REPOSE; ANGLE;
D O I
10.1252/kakoronbunshu.40.376
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A new apparatus was developed to evaluate the flowability of particles with poor flow behavior. This apparatus uses the phenomenon that particles drain from a particle-bed as stress on the bed is gradually increased. Samples employed were coarse particles with good flow behavior ( 133, 158, 306 mu m) and fine particles with poor flow behavior (1.6, 4.5, 32.9 mu m). The drained angles of coarse particles obtained with the new apparatus agree with those obtained with a conventional apparatus. Hence, the new apparatus is applicable for coarse particles. On the other hand, the drained angles of the fine particles could not be measured by the conventional method, as particles did not drain from the container. However, with the new apparatus, a particle-bed of fine particles (<= 4.5 mu m) suddenly collapsed drained at a certain level of applied stress. From this stress value, the forces acting between particles in the bed were calculated, and these forces agreed with those obtained with a direct shear tester. Thus, the new apparatus can also be used to estimate shear stress. Furthermore, the apparent drained angle is proposed as a new flow property for particles with poor flow behavior, and this allows the flowability of these particles to be evaluated.
引用
收藏
页码:376 / 381
页数:6
相关论文
共 50 条
  • [21] Development of an apparatus and procedure for evaluating the efficiency of nasal irrigation
    Wu, Dawei
    Chang, Feifan
    Hong, Junsheng
    Wei, Yongxiang
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (08) : 3997 - 4005
  • [22] A New Method for Evaluating the Bitterness of Medicines in Development Using a Taste Sensor and a Disintegration Testing Apparatus
    Harada, Tsutomu
    Uchida, Takahiro
    Yoshida, Miyako
    Kobayashi, Yoshikazu
    Narazaki, Ryuichi
    Ohwaki, Takayuki
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2010, 58 (08) : 1009 - 1014
  • [23] A new method for evaluating powder flowability using constant-volume shear tester
    Shimada, Yasuhiro
    Hatano, Shigenobu
    Matsusaka, Shuji
    ADVANCED POWDER TECHNOLOGY, 2018, 29 (12) : 3577 - 3583
  • [24] NEW STOPPED-FLOW APPARATUS
    PAPOFF, P
    MORELLI, B
    LAMPUGNA.L
    GAZZETTA CHIMICA ITALIANA, 1974, 104 (1-2): : 81 - 89
  • [25] NEW APPARATUS FOR MEASURING FLOW BIREFRINGENCE
    JANESCHITZKRIEGL, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1960, 31 (02): : 119 - 123
  • [26] NEW FLOW APPARATUS FOR STEADY AND STOPPED FLOW MEASUREMENTS
    NAKAMURA, T
    JOURNAL OF BIOCHEMISTRY, 1971, 70 (06): : 961 - &
  • [27] CFD modeling of particle dispersion behavior in the MIKE 3 apparatus
    Pan, Yangyue
    Spijker, Christoph
    Raupenstrauch, Harald
    ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (12) : 9305 - 9313
  • [28] DEVELOPMENT OF AN IN VITRO TECHNIQUE FOR EVALUATING HEPATIC PHAGOCYTIC MECHANISMS AND ROLE OF OPSONINS AS A FACTOR IN PARTICLE BEHAVIOR
    SABA, TM
    DILUZIO, NR
    JOURNAL OF THE RETICULOENDOTHELIAL SOCIETY, 1965, 2 (04): : 343 - &
  • [29] A NEW APPARATUS FOR MEASURING PARTICLE SIZES OF THE ORDER OF NANOMETER
    MORI, Y
    AN, H
    ENDO, K
    YAMAUCHI, K
    IDE, T
    INTERNATIONAL JOURNAL OF THE JAPAN SOCIETY FOR PRECISION ENGINEERING, 1991, 25 (03): : 214 - 219
  • [30] New apparatus for measuring particle sizes of the order of nanometer
    Mori, Yuzo
    An, Hiroshi
    Endo, Katsuyoshi
    Yamauchi, Kazuto
    Ide, Takashi
    Bulletin of the Japan Society of Precision Engineering, 1991, 25 (03): : 214 - 219