Safety factor calibration for a new model of shear strength of reinforced concrete building beams and slabs

被引:12
|
作者
Bairan, Jesus-Miguel [1 ]
Casas, Joan R. [1 ]
机构
[1] Univ Politecn Cataluna, Dept Civil & Environm Engn, BarcelonaTECH, Barcelona, Spain
关键词
Safety factor; Shear; Reinforced concrete; Assessment; Reliability; Building floors; Beams; Slabs; RC BEAMS; RESISTANCE; FAILURE; BRIDGE;
D O I
10.1016/j.engstruct.2018.06.033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
When assessing existing structures, the availability of adequate safety factors, calibrated with the most accurate models, and for established target reliability indexes, is of critical importance in order to take the right decision regarding the maintenance/repair/strengthening interventions. In the case of shear resistance in reinforced concrete (RC) structures, when using the current design codes provisions for new constructions in assessment results that, in many cases, existing structures may be considered unsafe, implying large economic costs in strengthening or even dismantling. In this research, a proposal of safety factor relative to a recently developed model for shear strength, for elements with and without transversal reinforcement, based on a reliability-based calibration is presented. A formulation is proposed to determine the adequate strength factor for a selected target reliability index of the existing structure and desired remaining service life by means of a safety factor format, considering the load factors present in the Eurocodes. The calibration is carried out considering typical geometry and load ratios of building floors, as well as normal and high strength concrete. The derived safety factor is almost independent of the chosen remaining service life.
引用
收藏
页码:293 / 303
页数:11
相关论文
共 50 条
  • [21] Shear strength of reinforced concrete beams with stirrups
    Arslan, Gueray
    MATERIALS AND STRUCTURES, 2008, 41 (01) : 113 - 122
  • [22] Shear Strength of Reinforced Concrete Beams Discussion
    Yuan, Jian
    ACI STRUCTURAL JOURNAL, 2015, 112 (03) : 408 - 409
  • [23] Shear Strength of Reinforced Concrete Deep Beams
    Lu, Wen-Yao
    Lin, Ing-Jaung
    Yu, Hsin-Wan
    ACI STRUCTURAL JOURNAL, 2013, 110 (04) : 671 - 680
  • [24] Shear strength of reinforced concrete slender beams
    Arslan, G.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2010, 163 (03) : 195 - 205
  • [25] Reinforced concrete deep beams - Shear strength model and design formula
    Russo, G
    Venir, R
    Pauletta, M
    ACI STRUCTURAL JOURNAL, 2005, 102 (03) : 429 - 437
  • [26] Danger of Shear Breakage of Reinforced Concrete Slabs for Building Constructions
    Schacht, Gregor
    Mueller, Lukas
    Curbach, Manfred
    Marx, Steffen
    BETON- UND STAHLBETONBAU, 2013, 108 (09) : 592 - 602
  • [27] Shear bearing behaviour of reinforced concrete slabs for building constructions
    Schubbruchgefahr von hochbautypischen Stahlbetonplattentragwerken
    1600, Ernst und Sohn (108):
  • [28] Shear strength model of FRP-reinforced concrete beams without shear reinforcement
    Dinh, Ngoc Hieu
    Roh, Young-Sook
    Truong, Gia Toai
    STRUCTURES, 2024, 64
  • [29] Shear strength of reinforced concrete beams with a fiber concrete matrix
    Majdzadeh, Fariborz
    Soleimani, Sayed Mohamad
    Banthia, Nemkumar
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2006, 33 (06) : 726 - 734
  • [30] Punching shear strength of steel fibre reinforced concrete slabs
    Maya, L. F.
    Ruiz, M. Fernandez
    Muttoni, A.
    Foster, S. J.
    ENGINEERING STRUCTURES, 2012, 40 : 83 - 94