Effect of ignition position on vented hydrogen-air deflagration in a 1 m3 vessel

被引:33
|
作者
Li, Hongwei [1 ]
Rui, Shengchao [2 ,3 ]
Guo, Jin [4 ]
Sun, Xuxu [5 ]
Li, Gang [6 ]
Zhang, Jiaqing [7 ]
机构
[1] Anhui Univ Sci & Technol, Sch Chem Engn, Huainan 232001, Anhui, Peoples R China
[2] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[3] Anhui Int Joint Res Ctr Hydrogen Safety, Hefei 230009, Anhui, Peoples R China
[4] Fuzhou Univ, Coll Environm & Resources, Fuzhou 350116, Fujian, Peoples R China
[5] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230009, Anhui, Peoples R China
[6] Northeastern Univ, Fire & Explos Protect Lab, Shenyang 110004, Liaoning, Peoples R China
[7] Anhui Elect Power Res Inst, Hefei 230601, Anhui, Peoples R China
关键词
Hydrogen; Vented explosion; Pressure oscillation; Flame; Safety; EXPLOSION OVERPRESSURES; CYLINDRICAL RIG; GAS EXPLOSION; PRESSURE; GASDYNAMICS; MITIGATION; LOCATION; DUCTS; SIZE; CFD;
D O I
10.1016/j.jlp.2019.103944
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study investigates the effect of the ignition position on vented hydrogen-air deflagration in a 1 m(3) vessel and evaluates the performance of the commercial computational fluid dynamics (CFD) code FLACS in simulating the vented explosion of hydrogen-air mixtures. First, the differences in the measured pressure-time histories for various ignition locations are presented, and the mechanisms responsible for the generation of different pressure peaks are explained, along with the flame behavior. Secondly, the CFD software FLAGS is assessed against the experimental data. The characteristic phenomena of vented explosion are observed for hydrogen-air mixtures ignited at different ignition positions, such as Helmholtz oscillation for front ignition, the interaction between external explosion and combustion inside the vessel for central ignition, and the wall effect for back-wall ignition. Flame-acoustic interaction are observed in all cases, particularly in those of front ignition and very lean hydrogen-air mixtures. The predicted flame behavior agree well with the experimental data in general while the simulated maximum overpressures are larger than the experimental values by a factor of 1.5-2, which is conservative then would lead to a safe design of explosion panels for instance. Not only the flame development during the deflagration was well-simulated for the different ignition locations, but also the correspondence between the pressure transients and flame behavior was also accurately calculated. The comparison of the predicted results with the experimental data shows the performance of FLACS to model vented mixtures of hydrogen with air ignited in a lab scale vessel. However, the experimental scale is often smaller than that used in practical scenarios, such as hydrogen refueling installations. Thus, future large-scale experiments are necessary to assess the performance of FLACS in practical use.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] The effect of vent burst pressure on a vented hydrogen-air deflagration in a 1 m3 vessel
    Rui, Shengchao
    Guo, Jin
    Li, Gang
    Wang, Changjian
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (45) : 21169 - 21176
  • [2] Effects of hydrogen concentration on the vented deflagration of hydrogen-air mixtures in a 1-m3 vessel
    Wang, Jingui
    Guo, Jin
    Yang, Fuqiang
    Zhang, Jiaqing
    Lu, Shouxiang
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (45) : 21161 - 21168
  • [3] Effect of ignition position on vented hydrogen-air explosions
    Guo, Jin
    Sun, Xuxu
    Rui, Shengchao
    Cao, Yong
    Hu, Kunlun
    Wang, Changjian
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (45) : 15780 - 15788
  • [4] Effect of concentration and ignition position on characteristics of premixed hydrogen-air deflagration
    Zheng L.
    Zhu X.
    Yu S.
    Wang Y.
    Li G.
    Du D.
    Dou Z.
    Su Y.
    Huagong Xuebao/CIESC Journal, 2019, 70 (01): : 408 - 416
  • [5] Effect of the Ignition Position and Obstacle on Vented Methane–Air Deflagration
    J.-L. Li
    J. Guo
    X.-X. Sun
    F.-Q. Yang
    Combustion, Explosion, and Shock Waves, 2023, 59 : 608 - 619
  • [6] Effect of the Ignition Position and Obstacle on Vented Methane-Air Deflagration
    Li, J. -l.
    Guo, J.
    Sun, X. -X.
    Yang, F. -Q
    COMBUSTION EXPLOSION AND SHOCK WAVES, 2023, 59 (05) : 608 - 619
  • [7] Vented deflagration of a hydrogen-air mixture in a rectangular vessel with a hinged aluminum vent panel
    Zhang, Su
    Guo, Jin
    Yang, Fuqiang
    Wang, Jingui
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (40) : 22733 - 22739
  • [8] Vented hydrogen-air deflagration in a small enclosed volume
    Rocourt, X.
    Awamat, S.
    Sochet, I.
    Jallais, S.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (35) : 20462 - 20466
  • [9] Ceiling-vented deflagrations of a hydrogen-air mixture in a 75 m3 container
    Li, Quan
    Rui, Shengchao
    Luo, Xinjiao
    Wang, Changjian
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (62) : 31916 - 31925
  • [10] Effects of ignition position and hydrogen concentration on the flame propagation characteristics of hydrogen-air deflagration
    Wang, Qiuhong
    Wan, Hongxiang
    Bi, Mingshu
    Gao, Wei
    Peng, Bin
    Luo, Zhenmin
    Chen, Jian
    Xue, Yunfan
    FUEL, 2024, 359