Optimization of illumination profiles in line-scan camera systems

被引:0
|
作者
Karjalainen, PA
Lappalainen, T
机构
[1] Univ Kuopio, Dept Appl Phys, FIN-70211 Kuopio, Finland
[2] VTT Energy, Tech Res Ctr Finland, FIN-40101 Jyvaskyla, Finland
关键词
illumination; line-scan camera; optimization; regularization;
D O I
10.1088/0957-0233/11/9/307
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A method for the optimization of illumination in line-scan camera systems is proposed. By using this method it is possible to calculate the optimal positions and luminous intensities of the light sources to obtain the desired illuminance at a surface. The proposed method is especially suitable fur producing uniform illumination on a line. The method can be used with several types of light source, because experimental general models can be used for the lamps. The method is based on the regularized least squares optimization. The performance of the method is evaluated by comparing the calculated and measured illuminances before: and after the optimization.
引用
收藏
页码:1301 / 1306
页数:6
相关论文
共 50 条
  • [31] NOISY LINE-SCAN PICTURES
    WAGENAAR, WA
    VANMEETE.A
    PHOTOGRAMMETRIC ENGINEERING, 1969, 35 (11): : 1127 - &
  • [32] Calibration of Line-Scan Cameras
    Luna, Carlos A.
    Mazo, Manuel
    Luis Lazaro, Jose
    Vazquez, Juan F.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (08) : 2185 - 2190
  • [33] LINE-SCAN IMAGERY INTERPRETATION
    DELOOR, GP
    JURRIENS, AA
    LEVELT, WJM
    VANDEGEE.JP
    PHOTOGRAMMETRIC ENGINEERING, 1968, 34 (05): : 502 - &
  • [34] Understanding line-scan cameras
    Riemer, Klaus
    Assembly, 2021, 64 (11):
  • [35] A robust line-scan camera-based inspection system for ink jet nozzle
    Kipman, Y
    Wolin, D
    Johnson, K
    MACHINE VISION APPLICATIONS IN INDUSTRIAL INSPECTION IX, 2001, 4301 : 1 - 8
  • [36] Flexible line-scan camera calibration method using a coded eight trigrams pattern
    Song, Kechen
    Hou, Bin
    Niu, Menghui
    Wen, Xin
    Yan, Yunhui
    OPTICS AND LASERS IN ENGINEERING, 2018, 110 : 296 - 307
  • [37] FPGA based Neural Network PID Controller for Line-scan Camera in Sensorless Environment
    Wang, Jianzhuang
    Chen, Youping
    Xie, Jingming
    Chen, Bing
    Zhou, Zude
    ICNC 2008: FOURTH INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION, VOL 6, PROCEEDINGS, 2008, : 157 - 161
  • [38] The Geometric Transformation Model of Two Views Based on the Line-Scan Camera Imaging Model
    Fang, Lei
    Shi, Zelin
    Liu, Yunpeng
    Li, Chenxi
    Zhao, Enbo
    INTELLIGENT ROBOTICS AND APPLICATIONS (ICIRA 2022), PT IV, 2022, 13458 : 113 - 124
  • [39] Multi-dimensional high-precision calibration method for line-scan camera
    Yuan G.-Q.
    Zheng L.-N.
    Zhang H.-W.
    Ding Y.-L.
    Sun J.-J.
    Yu C.-F.
    Zhang Z.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (08): : 1901 - 1907
  • [40] A RAPID LINE-SCAN CAMERA SYSTEM APPLIED TO MOVEMENTS OF COCHLEAR HAIR-CELLS
    CRAWFORD, AC
    EVANS, MG
    FETTIPLACE, R
    JOURNAL OF PHYSIOLOGY-LONDON, 1988, 407 : P5 - P5