Assessments of Structural Health Monitoring for Fatigue Cracks in Metallic Structures by Using Lamb Waves Driven by Piezoelectric Transducers

被引:11
|
作者
Chen, Chung-De [1 ]
Chiu, Yu-Cheng [1 ]
Huang, Yao-Hung [2 ]
Wang, Po-Hao [2 ]
Chien, Rong-Der [2 ]
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, 1 Univ Rd, Tainan 701, Taiwan
[2] Aerosp Ind Dev Corp, Dept Struct Anal, 1 Hanxiang Rd, Taichung 40760, Taiwan
关键词
Structural health monitoring (SHM); Lamb wave; Probability of detection (POD); Piezoelectric transducer; SENSOR/ACTUATOR NETWORK; COMPOSITE STRUCTURES; DAMAGE DETECTION; REPAIR; SYSTEM;
D O I
10.1061/(ASCE)AS.1943-5525.0001212
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
In this paper, the assessments of structural health monitoring (SHM) for metallic structures are presented. Tests were conducted on three specimens for fatigue crack testing and damage index measurements. In each specimen, a transducer array of six Stanford Multiactuator-Receiver Transduction (SMART) Layers, each of which contains a piezoelectric transducer, was mounted near the fatigue crack. The Lamb wave was driven by one SMART Layer and received by another. The transducer array generated nine forward and nine backward propagating paths. The damage index defined in the first arrival window (FAW) was obtained for each path. In this work, we propose an averaging process to obtain average damage index from the transducer array. The Lamb waves with various driving frequencies were tested to conduct the performance of the damage monitoring. The results show that the plot of the average damage index versus the actual crack length reveals a narrow band, indicating a small standard deviation of the measurement data. The data of numerous crack lengths and Lamb wave paths are processed statistically to determine the probability of detection (POD) of this damage detection method. It was found that the Lamb wave with the driving frequency of f = 450 kHz performed best in the crack monitoring. By using an threshold damage index DIth = 0.01, the detectable crack sizes a(50/50), a(90/50), and a(90)(/95) for the case of f = 450 kHz are 4.83, 5.79, and 5.92 mm, respectively. Based on the proposed approach, the relations between the damage index and actual crack length and the POD curves can be applicable to a real structure with the same geometry. (C) 2020 American Society of Civil Engineers.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Structural health monitoring system using piezoelectric networks with tuned lamb waves
    Rocha, Bruno
    Silva, Carlos
    Suleman, Afzal
    [J]. SHOCK AND VIBRATION, 2010, 17 (4-5) : 677 - 695
  • [2] Structural health monitoring of composite structures using guided lamb waves
    Balasubramaniam, Krishnan
    Sekhar, B. V. Soma
    Vardan, J. Vishnu
    Krishnamurthy, C. V.
    [J]. ADVANCED NONDESTRUCTIVE EVALUATION I, PTS 1 AND 2, PROCEEDINGS, 2006, 321-323 : 759 - 764
  • [3] SIMULATION OF INTERACTION BETWEEN LAMB WAVES AND CRACKS FOR STRUCTURAL HEALTH MONITORING WITH PIEZOELECTRIC WAFER ACTIVE SENSORS
    Shen, Yanfeng
    Giurgiutiu, Victor
    [J]. PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, VOL 1, 2012, : 615 - 623
  • [4] STRUCTURAL HEALTH MONITORING USING PIEZOELECTRIC TRANSDUCERS AND WAVELETS
    Shih, Hui-Ru
    McIntyre, Albert C.
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 5, 2014,
  • [5] Interdigital Transducers in Structural Health Monitoring Based on Lamb Waves - A State of the Art
    Stepinski, Tadeusz
    Manka, Michal
    Martowicz, Adam
    Rathod, Vivek T.
    [J]. SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2016, 2016, 9803
  • [6] THE APPLICATION OF PIEZOELECTRIC TRANSDUCERS IN THE STRUCTURAL HEALTH MONITORING OF REINFORCE CONCRETE STRUCTURES
    Stojic, Dragoslav
    Nestorovic, Tamara
    Markovic, Nemanja
    [J]. 12TH INTERNATIONAL MULTIDISCIPLINARY SCIENTIFIC GEOCONFERENCE, SGEM 2012, VOL. II, 2012, : 641 - +
  • [7] Health monitoring of composite structures using composite piezoelectric transducers
    Blanas, F
    Rigas, E
    Das-Gupta, DK
    [J]. STRUCTURAL HEALTH MONTORING 2000, 1999, : 635 - 642
  • [8] DESIGN OF A PZT SENSOR NETWORK BASED ON GUIDED LAMB WAVES FOR STRUCTURAL HEALTH MONITORING OF METALLIC STRUCTURES
    Rocha, Bruno
    Silva, Carlos
    Suleman, Afzal
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2010, VOL 13, 2012, : 471 - 480
  • [9] Advances in the Structural Health Monitoring of Bridges Using Piezoelectric Transducers
    Chen, Yunzhu
    Xue, Xingwei
    [J]. SENSORS, 2018, 18 (12)
  • [10] Load monitoring and compensation strategies for guided-waves based structural health monitoring using piezoelectric transducers
    Roy, Surajit
    Ladpli, Purim
    Chang, Fu-Kuo
    [J]. JOURNAL OF SOUND AND VIBRATION, 2015, 351 : 206 - 220