The thermodynamic performance of a new solution cycle in double absorption heat transformer using water/lithium bromide as the working fluids

被引:34
|
作者
Zhao, ZC [1 ]
Zhou, FW [1 ]
Zhang, XD [1 ]
Li, SP [1 ]
机构
[1] Dalian Univ Technol, Res Inst Chem Engn, Dalian 116012, Liaoning, Peoples R China
关键词
refrigerating system; absorption system; water/lithium bromide; innovation; design; performance;
D O I
10.1016/S0140-7007(02)00114-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a new solution cycle in the double absorption heat transformer is presented and the thermodynamic performance of this new cycle is simulated based on the thermodynamic properties of aqueous solution of lithium bromide. The results show that this new cycle is superior to the cycle being studied by some researchers. This new, solution cycle has a wider range of operation in which the system maintains the high value of COP and has larger temperature lifts and operation stability. The relationship between the absorber and the absorbing evaporator is more independent and this makes the operation and control of the system more easier. (C) 2003 Elsevier Science Ltd and IIR. All rights reserved.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 50 条
  • [31] Development of a New Absorption-Demixing Heat Transformer: Cycle and Working Mixture Optimization
    Noubli, Halima
    Alonso, Dominique
    Renaudin, Viviane
    Cachot, Thierry
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2010, 8
  • [32] Thermodynamic properties and evaluation of the lithium nitrate-imidazole IL-water ternary systems as new working fluids for a double-effect AHP cycle
    Luo, Chunhuan
    Li, Yiqun
    Li, Na
    Su, Qingquan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 90 : 58 - 72
  • [33] 2ND-LAW ANALYSIS OF SOLAR ABSORPTION-COOLING CYCLES USING LITHIUM BROMIDE WATER AND AMMONIA WATER AS WORKING FLUIDS
    KARAKAS, A
    EGRICAN, N
    UYGUR, S
    APPLIED ENERGY, 1990, 37 (03) : 169 - 187
  • [34] THERMODYNAMIC FEASIBILITY OF DOUBLE EFFECT GENERATION ABSORPTION SYSTEM USING WATER SALT AND ALCOHOL SALT MIXTURES AS WORKING FLUIDS
    KAUSHIK, SC
    CHANDRA, S
    GADHI, SMB
    JOURNAL OF HEAT RECOVERY SYSTEMS, 1985, 5 (01): : 19 - 26
  • [35] Exergy analysis of double absorption heat transformers with a new solution cycle
    Zhang, Xiao-Dong
    Li, Jian-Feng
    Dalian Ligong Daxue Xuebao/Journal of Dalian University of Technology, 2007, 47 (03): : 333 - 337
  • [36] Performance analysis of double absorption heat transformers with solution and coolant heat regeneration cycle
    Ji G.
    Chen Y.
    Wu J.
    Ji G.
    Chen, Yaping (ypgchen@sina.com), 1600, Southeast University (47): : 85 - 90
  • [37] Experimental assessment of a detachable plate falling film heat and mass exchanger couple using lithium bromide and water as working fluids
    Yi, Yuhao
    Hu, Tianle
    Xie, Xiaoyun
    Jiang, Yi
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 113 : 219 - 227
  • [38] Operation of an absorption heat transformer using water/ionic liquid as working fluid
    Merkel, Nina
    Buecherl, Markus
    Zimmermann, Matthias
    Wagner, Volker
    Schaber, Karlheinz
    APPLIED THERMAL ENGINEERING, 2018, 131 : 370 - 380
  • [39] Performance study of a double-absorption water calcium chloride heat transformer
    Barragan, RM
    Arellano, VM
    Heard, CL
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1998, 22 (09) : 791 - 803
  • [40] Effect of operating temperature on the performance and thermal load of Water/Lithium Bromide vapour absorption heat pump in the absence of solution heat Exchanger
    Manu, S.
    Chandrashekar, T. K.
    Antony, A. J.
    DYNAMICS OF MACHINES AND MECHANISMS, INDUSTRIAL RESEARCH, 2014, 592-594 : 1510 - +