Immunohistological and flow cytometric analysis of glycosphingolipid expression in mouse lymphoid tissues

被引:16
|
作者
Kovacic, N
Müthing, J
Marusic, A
机构
[1] Univ Zagreb, Sch Med, Croatian Inst Brain Res, Zagreb 10000, Croatia
[2] Univ Zagreb, Sch Med, Dept Anat, Zagreb 10000, Croatia
[3] Univ Bielefeld, Tech Fac, Inst Cell Culture Technol, D-4800 Bielefeld, Germany
关键词
flow cytometry; gangliosides; glycosphingolipids; immunohistology; in vivo; lymph node; mouse; spleen; thymus;
D O I
10.1177/002215540004801211
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Expression of neutral glycosphingolipids (GSLs) and gangliosides in normal lymphoid tissues and cells has been studied mostly by biochemical and immunochemical analysis of lipid extracts separated by thin-layer chromatography. CSLs and gangliosides involved in the GM1b biosynthetic pathway were assigned to T-lymphocytes, whereas B-cell gangliosides and GSLs have been poorly characterized in former publications. We used specific polyclonal antibodies in immunohistochemistry and flow cytometry to analyze the distribution of globotriaosylceramide (Gb(3)Cer), globoside (Gb(4)Cer), gangliotriaosylceramide (Gg(3)Cer), gangliotetraosylceramide (Gg(4)Cer), and gangliosides GM3 and GalNAc-GM1b in the mouse thymus, spleen, and lymph node. immature thymocytes expressed epitopes recognized by all antibodies, except for anti-Gb(4)Cer. Mature thymocytes bound only antibodies to GalNAcGM1b Gg4Cer, and Gb4Cer. In secondary lymphoid organs, antibodies to globe-series GSLs bound to vascular spaces of secondary lymphoid organs, whereas the ganglio-series GSL antibodies recognized lymphocyte-containing regions. In a Western blotting analysis, only GalNAc-GM1b antibody recognized a specific protein band in ail three organs. Flow cytometric analysis of spleen and lymph node cells revealed that B-cells carried epitopes recognized by all antibodies, whereas the T-cell GSL repertoire was mostly oriented to ganglio-series-neutral CSLs and GM1b-type gangliosides. The results of immunohistochemistry and flow cytometry were not always identical, possibly because of crossreactivity to glycoprotein-linked oligosaccharides and/or differences between cell surface carbohydrate profiles of isolated cells and cells in a tissue environment.
引用
收藏
页码:1677 / 1689
页数:13
相关论文
共 50 条
  • [11] Comprehensive analysis of glycosphingolipid expression in the human and mouse cornea
    Martinez-Carrasco, Rafael
    Argueso, Pablo
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [12] Flow cytometric analysis of androgen receptor expression in human prostate tumors and benign tissues
    Krishan, A
    Oppenheimer, A
    You, W
    Dubbin, R
    Sharma, D
    Lokeshwar, BL
    [J]. CLINICAL CANCER RESEARCH, 2000, 6 (05) : 1922 - 1930
  • [13] FLOW CYTOMETRIC ANALYSIS OF DNA IN CELLS OBTAINED FROM DEPARAFFINIZED FORMALIN-FIXED LYMPHOID-TISSUES
    MCINTIRE, TL
    GOLDEY, SH
    BENSON, NA
    BRAYLAN, RC
    [J]. CYTOMETRY, 1987, 8 (05): : 474 - 478
  • [14] A Protocol for the Comprehensive Flow Cytometric Analysis of Immune Cells in Normal and Inflamed Murine Non-Lymphoid Tissues
    Yu, Yen-Rei A.
    O'Koren, Emily G.
    Hotten, Danielle F.
    Kan, Matthew J.
    Kopin, David
    Nelson, Erik R.
    Que, Loretta
    Gunn, Michael D.
    [J]. PLOS ONE, 2016, 11 (03):
  • [15] Flow cytometric analysis of lymphoid cells in thymic epithelial neoplasms
    Nakajima, J
    Takamoto, S
    Oka, T
    Tanaka, M
    Takeuchi, E
    Murakawa, T
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 18 (03) : 287 - 292
  • [16] FLOW CYTOMETRIC ANALYSIS OF NORMAL B-LYMPHOID DEVELOPMENT
    LOKEN, MR
    SHAH, VO
    HOLLANDER, Z
    CIVIN, CI
    [J]. PATHOLOGY AND IMMUNOPATHOLOGY RESEARCH, 1988, 7 (05): : 357 - +
  • [17] Flow cytometric analysis of innate lymphoid cells: challenges and solutions
    Sadeghalvad, Mona
    Khijakadze, Davit
    Orangi, Mona
    Takei, Fumio
    [J]. FRONTIERS IN IMMUNOLOGY, 2023, 14
  • [18] Comparative analysis of light chain expression in germinal center cells and mantle cells of reactive lymphoid tissues - A four-color flow cytometric study
    Reichard, KK
    McKenna, RW
    Kroft, SH
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 119 (01) : 130 - 136
  • [19] Flow cytometric analysis of mouse neurospheres based on the expression level of RANDAM-2
    Kotani, Masaharu
    Okamoto, Shiki
    Imada, Masato
    Itoh, Kouichi
    Irie, Atsushi
    Sakuraba, Hitoshi
    Kubo, Hideo
    [J]. NEUROSCIENCE LETTERS, 2007, 413 (01) : 25 - 30
  • [20] Comparative analysis of light chain expression in germinal center cells and mantle cells of reactive lymphoid tissues: A four-color flow cytometric study.
    Espenshade, KK
    Aquino, DB
    McKenna, RW
    Kroft, SH
    [J]. MODERN PATHOLOGY, 2001, 14 (01) : 162A - 162A