Comparison of Initial Implant Stability of Implants Placed Using Bicortical Fixation, Indirect Sinus Elevation, and Unicortical Fixation

被引:11
|
作者
Hsu, Andrea
Seong, Wook-Jin [1 ]
Wolff, Ryan [2 ]
Zhang, Lei [3 ]
Hodges, James [4 ]
Olin, Paul S. [1 ]
Hinrichs, James E. [2 ]
机构
[1] Univ Minnesota, Div Prosthodont, Dept Restorat Sci, Sch Dent, 9-470 Moos Tower,515 Delaware St SE, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Div Periodont, Dept Dev & Surg Sci, Sch Dent, 9-470 Moos Tower,515 Delaware St SE, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Biostat Design & Anal Ctr, CTSI, 9-470 Moos Tower,515 Delaware St SE, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Div Biostat, Sch Publ Hlth, 9-470 Moos Tower,515 Delaware St SE, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
bicortical ixation; initial implant stability; RESONANCE FREQUENCY-ANALYSIS; LIFE-TABLE ANALYSIS; FLOOR ELEVATION; DENTAL IMPLANTS; POSTERIOR MAXILLA; ITI IMPLANTS; PART II; BONE; OSSEOINTEGRATION; ANCHORAGE;
D O I
10.11607/jomi.4142
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to determine if self-threading dental implants placed using stopper drills to bicortically engage both the alveolar crest and sinus loor (bicortical ixation) achieved primary and/or secondary stability comparable to that of short implants only engaging alveolar crest cortical bone (unicortical ixation) or implants engaging both the crest and sinus loor but via greenstick fracture and grafting (indirect sinus elevation). Materials and Methods: Thirty-eight patients exhibiting 7 to 11 mm of bone coronal to the sinus loor as conirmed by preoperative CBCT were recruited. Forty-ive implants were randomly assigned to one of the placement techniques. No patient received more than two implants, which were placed in opposite sides of the maxilla while using different surgical techniques. An Osstell ISQ was employed immediately after implant placement to measure stability six times in a buccolingual dimension. Secondary stability was measured at stage-two surgery after a 3- to 6-month healing period. Results: The greatest primary implant stability was achieved via indirect sinus elevation. However, no statistically significant difference was found among the three surgical techniques (P = .13; bicortical ixation: 71.4 [standard error = 2.1]), unicortical ixation: 69.6 [2.1], indirect sinus elevation: 75.9 [2.3]). The three techniques had similar secondary stability (P > .999; 79.9 [1.2], 80.0 [1.2], and 80.0 [1.3], respectively). Baseline residual ridge height measured on CBCT was similar (P = .1; 8.8, 9.9, and 9.4 mm, respectively), but implant diameter and length placed in the maxilla differed (P = .03/P < .001; 4.7/11.4 mm, 4.3/8.1 mm, and 4.7/11.8 mm, respectively). Primary implant stability was significantly correlated to CBCT bone density (r = 0.37). Conclusion: Primary and secondary implant stabilities of bicortical ixation did not differ significantly from those of unicortical ixation and indirect sinus elevation. However, use of the bicortical ixation technique is warranted since it is simpler and more economical than indirect sinus elevation; plus, it allows for longer implants than the unicortical ixation while yielding similar secondary implant stability.
引用
收藏
页码:459 / 468
页数:10
相关论文
共 50 条
  • [21] Biomechanical Comparison of Bicortical Locking Versus Unicortical Far-Cortex-Abutting Locking Screw-Plate Fixation for Comminuted Radial Shaft Fractures
    Overturf, Steven J.
    Morris, Randal P.
    Gugala, Zbigniew
    Lindsey, Ronald W.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (10): : 1907 - 1913
  • [22] Fixation stability and implant-associated complications in periacetabular osteotomy: a comparison of screw and K-wire fixation
    Leopold, Vincent Justus
    Conrad, Juana
    Zahn, Robert Karl
    Hipfl, Christian
    Perka, Carsten
    Hardt, Sebastian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (02) : 691 - 697
  • [23] Fixation stability and implant-associated complications in periacetabular osteotomy: a comparison of screw and K-wire fixation
    Vincent Justus Leopold
    Juana Conrad
    Robert Karl Zahn
    Christian Hipfl
    Carsten Perka
    Sebastian Hardt
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 691 - 697
  • [24] Commentary on "Biomechanical Comparison of Bicortical Locking Versus Unicortical Far-Cortex-Abutting Locking Screw-Plate Fixation for Comminuted Radial Shaft Fractures"
    Pappas, Nick D.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (10): : 1914 - 1914
  • [25] Biomechanical comparison of a novel monocortical and two common bicortical external fixation systems regarding rigidity and dynamic stability
    Varady, Patrick A.
    Greinwald, Markus
    Augat, Peter
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2018, 63 (06): : 665 - 672
  • [26] Biomechanical Analysis of the Less Invasive Stabilization System for Mechanically Unstable Fractures of the Distal Femur: Comparison of Titanium Versus Stainless Steel and Bicortical Versus Unicortical Fixation
    Beingessner, Daphne
    Moon, Edward
    Barei, David
    Morshed, Saam
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (03): : 620 - 624
  • [27] Lag Screw Fixation of Medial Malleolar Fractures: A Biomechanical, Radiographic, and Clinical Comparison of Unicortical Partially Threaded Lag Screws and Bicortical Fully Threaded Lag Screws
    Ricci, William M.
    Tornetta, Paul
    Borrelli, Joseph, Jr.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (10) : 602 - 606
  • [28] A biomechanical analysis of plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to 4-point bending and dynamical bending test
    Liodaki, Eirini
    Wendlandt, Robert
    Waizner, Klaus
    Schopp, Brigitte E.
    Mailaender, Peter
    Stang, Felix
    MEDICINE, 2017, 96 (27)
  • [29] Comparison of nonself-tapping tapered implant and self-tapping hybrid implant in terms of implant stability at initial and second fixation: A prospective randomized clinical trial
    Moroi, Akinori
    Saito, Yuki
    Takayama, Akihiro
    Ueki, Koichiro
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (06) : 679 - 688
  • [30] Implants Placed Simultaneously With Lateral Window Sinus Augmentation Using a Putty Alloplastic Bone Substitute for Increased Primary Implant Stability: A Retrospective Study
    Kher, Udatta
    Mazor, Ziv
    Stanitsas, Panagiotis
    Kotsakis, Georgios A.
    IMPLANT DENTISTRY, 2014, 23 (04) : 496 - 501