Reliability of home blood pressure monitoring devices in pregnancy

被引:20
|
作者
Tremonti, Chris [1 ,2 ]
Beddoe, Jennifer [3 ]
Brown, Mark A. [3 ]
机构
[1] Royal North Shore Hosp, St Leonards, NSW 2065, Australia
[2] Sutherland Hosp, Sutherland, NSW 2229, Australia
[3] St George Hosp, Kogarah, NSW 2217, Australia
关键词
Home blood pressure monitors; Gestational hypertension; Pregnancy; Blood pressure; Automated BP; HYPERTENSION-SOCIETY PROTOCOL; SELF-MEASUREMENT; INTERNATIONAL PROTOCOL; EUROPEAN-SOCIETY; VALIDATION; PREECLAMPSIA; ACCURACY; WOMEN; SPHYGMOMANOMETERS; POPULATION;
D O I
10.1016/j.preghy.2017.01.002
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Home blood pressure monitors are freely available and used for women during pregnancy. The exact role of home blood pressure monitoring in pregnancy remains uncertain, and few such monitors have been validated for use in pregnancy. As it has been our Unit's policy to test these devices against sphygmomanometry (as the gold standard) before clinical use for some years now, we undertook this study to ascertain the degree of accuracy or inaccuracy of these devices in usual clinical practice. We analysed 9 consecutive blood pressures (BP) alternately using an automated home BP device and sphygmomanometry in 127 pregnant women with hypertension using two different methods: a) a modified version of the British Hypertension Society's guidelines for analysing automated devices, and b) examining the difference between the mean of blood pressure readings by the device and sphygmomanometry for each patient. 87 devices (69%) had systolic BP within 5 mmHg or less and 98 (77%) were within 5 mmHg for diastolic BP. The frequency of systolic BPs within 5 mmHg was similar for non-validated vs. validated devices (75 vs. 60%; p = 0.23). Similarly, diastolic BP within 5 mmHg was similar for non-validated vs. validated devices (86 vs. 68%, p = 0.06). Our findings showed that a wide variety of devices are used and few if any have been formally validated for use in pregnancy. As a group the devices provide accurate BP in the majority of women, but up to a quarter will have a BP difference of at least 5 mmHg, and this is not related to the absolute BP. Furthermore using a home BP device validated for general use in non-pregnant subjects appeared as reliable as using other non-validated devices. On the basis of these data we recommended clinicians always perform their own analysis of a patient's home BP machine accuracy prior to home use using a simple protocol as described here, even if the machine has been validated for general use. (C) 2017 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:9 / 14
页数:6
相关论文
共 50 条
  • [41] Home Blood Pressure Monitoring and Blood Pressure Control in Treated Hypertensives
    Brandao, Andrea Araujo
    Sebba Barroso, Weimar Kunz
    Feitosa, Audes
    Duarte Barbosa, Eduardo Costa
    Miranda, Roberto Dischinger
    de Oliveira Vitorino, Priscila Valverde
    Pozzan, Roberto
    Ribeiro, Lucio Paulo
    Epelman, Abraham
    Saraiva, Giovanni Alves
    Silveira, Fabio Serra
    Braga, Antonio Almeida
    Gomes, Marco Mota
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2022, 119 (02) : 353 - 357
  • [42] Devices for ambulatory and home monitoring of blood pressure, lipids, coagulation, and weight management, part 1
    Scolaro, KL
    Stamm, PL
    Lloyd, KB
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2005, 62 (17) : 1802 - 1812
  • [43] Devices for ambulatory and home monitoring of blood pressure, lipids, coagulation, and weight management, part 2
    Scolaro, KL
    Stamm, PL
    Lloyd, KB
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2005, 62 (18) : 1894 - 1903
  • [44] Home Blood Pressure Monitoring Devices: Device Performance in an Alaska Native and American Indian Population
    Schaefer, Krista R.
    Fyfe-Johnson, Amber L.
    Noonan, Carolyn J.
    Todd, Michael R.
    Umans, Jason G.
    Castille, Dorothy M.
    Rosenman, Robert
    Buchwald, Dedra S.
    Dillard, Denise A.
    Robinson, Renee F.
    Muller, Clemma J.
    JOURNAL OF AGING AND HEALTH, 2021, 33 (7-8_SUPPL) : 40S - 50S
  • [45] CURRENT STATUS OF USE OF VALIDATED DEVICES FOR HOME BLOOD PRESSURE MONITORING AMONG PATIENTS WITH HYPERTENSION
    Lee, Ji Eun
    Yoo, Seungwon
    Kim, Dae-Young
    Shin, Sung-Hee
    Na, Jin Oh
    Shin, Jinho
    Park, Kiho
    Lee, Eun Mi
    JOURNAL OF HYPERTENSION, 2024, 42
  • [46] Home Blood Pressure Monitoring in Heart Transplant Recipients: Comparison with Ambulatory Blood Pressure Monitoring
    Ambrosi, Pierre
    Kreitmann, Bernard
    Habib, Gilbert
    TRANSPLANTATION, 2014, 97 (03) : 363 - 367
  • [47] A comparison of office blood pressure, telemedical home blood pressure and ambulatory blood pressure monitoring
    Hoffmann-Petersen, N.
    Tambo, T.
    Pedersen, E. Bjerregaard
    EUROPEAN HEART JOURNAL, 2014, 35 : 573 - 573
  • [48] Evaluation of the efficacy of blood glucose home monitoring devices
    Bastanhagh, Mohammad Hassan
    Shirvan, Adeleh Rezagholizadeh
    Heshmat, Ramin
    Khalilifard, Alireza
    Keshtkar, Abbasali
    Larijani, Bagher
    MEDICAL SCIENCE MONITOR, 2007, 13 (03): : PI1 - PI6
  • [49] Home Blood Pressure Monitoring And Nocturia In Adults
    Lazar, Jason M.
    Posner, Alexandra
    Akbar, Kamal
    Tologonova, Gulzhan
    Monaghan, Thomas
    Murray, Christopher
    Weiss, Jeffrey
    Everaert, Karel
    DeBacker, Tine
    Helzner, Elizabeth
    Calixte, Rose
    Browne, Rasheda
    Goldman, Sarah
    Salciccioli, Louis
    JOURNAL OF COMMUNITY HEALTH, 2023, 48 (02) : 238 - 244
  • [50] HOME BLOOD-PRESSURE MONITORING IN DIABETES
    GOMPELS, C
    SAVAGE, D
    ARCHIVES OF DISEASE IN CHILDHOOD, 1992, 67 (05) : 636 - 639