Modified transmission type four detectors polarimeter

被引:4
|
作者
Kawabata, S [1 ]
机构
[1] Tokyo Polytech Univ, Atsugi, Kanagawa 2430297, Japan
关键词
polarized light; ellipsometry; polarimeter; birefringence;
D O I
10.1117/55.75893
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A four detectors polarimeter is originally invented by Azzam et. al. We have modified their idea and developed a new four detectors polarimeter of a transmission type (T-FDP) which has some advantages over the conventional one. Further modification of our T-FDP to the M-TFDP is reported. The alignment procedure of the optical system is also discussed as the application of the M-TFDP to ellipsometry.
引用
收藏
页码:337 / 344
页数:8
相关论文
共 50 条
  • [31] A FLOW-TYPE CUVETTE FOR THE PORTABLE POLARIMETER
    KARDASH, BE
    GEITMAN, IY
    LABORATORNOE DELO, 1982, (06): : 379 - 380
  • [32] Development of material evaluation method by using a pulsed neutron transmission with pixel type detectors
    Sato, H.
    Takada, O.
    Satoh, S.
    Kamiyama, T.
    Kiyanagi, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 597 - 599
  • [33] Commissioning of RHIC and its four detectors
    Paul, P
    NUCLEAR PHYSICS A, 2001, 685 : 449C - 453C
  • [34] Performance limitations of a four-channel polarimeter in the presence of detection noise
    Gamiz, VL
    Belsher, JF
    OPTICAL ENGINEERING, 2002, 41 (05) : 973 - 980
  • [35] Performance of a four channel polarimeter with very low light level detection
    Gamiz, VL
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES II, 1998, 3498 : 446 - 457
  • [36] Microsphere plate detectors used with a compact Mott polarimeter for time-of-flight studies
    Snell, G
    Viefhaus, J
    Dunning, FB
    Berrah, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (06): : 2608 - 2609
  • [37] Systematic error cancellation for the PIXIE four-port interferometric polarimeter
    Kogut, Alan
    Fixsen, Dale J.
    MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY IX, 2018, 10708
  • [38] Spectroscopic Mueller matrix polarimeter using four-channeled spectra
    Otani, Yukitoshi
    Wakayama, Toshitaka
    Oka, Kazuhiko
    Umeda, Norihiro
    OPTICS COMMUNICATIONS, 2008, 281 (23) : 5725 - 5730
  • [39] Demonstration of snapshot imaging polarimeter using modified Savart polariscopes
    Cao, Qizhi
    Zhang, Jing
    DeHoog, Edward
    Zhang, Chunmin
    APPLIED OPTICS, 2016, 55 (05) : 954 - 959
  • [40] Monte Carlo efficiency transfer method for full energy peak efficiency calibration of three type HPGe detectors: A coaxial N-type, a coaxial P-type and four BEGe detectors
    Liu Liye
    Ma Jizeng
    Franck, Didier
    de Carlan, Loic
    Zhang Binquan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 564 (01): : 608 - 613