A staphylococcal enterotoxin B magnetoelastic immunosensor

被引:83
|
作者
Ruan, CM
Zeng, KF
Varghese, OK
Grimes, CA [1 ]
机构
[1] Penn State Univ, Dept Elect Engn, Mat Res Lab 217, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Mat Sci & Engn, Mat Res Lab 217, University Pk, PA 16802 USA
来源
BIOSENSORS & BIOELECTRONICS | 2004年 / 20卷 / 03期
关键词
staphylococcal enterotoxin B; magnetoelastic sensor; immunosensor; biocatalytic precipitation; biotin-avidin;
D O I
10.1016/j.bios.2004.03.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A magnetoelastic immunosensor for detection of staphylococcal enterotoxin B (SEB) is described. The magnetoelastic sensor is a newly developed mass/elasticity-based transducer of high sensitivity having a material cost of approximately $0.001/sensor. Affinity-purified rabbit anti-SEB antibody was covalently immobilized on magnetoelastic sensors, of dimensions 6 mm x 2 mm x 28 mum. The affinity reaction of biotin-avidin and biocatalytic precipitation are used to amplify antigen-antibody binding events on the sensor surface. Horseradish peroxidase (HRP) and alkaline phosphatase were examined as the labeled enzymes to induce biocatalytic precipitation. The alkaline phosphatase substrate, 5-bromo-4-chloro-3-indolyl phosphate (BCIP) produces a dimer, which binds tightly to the sensor surface, inducing a change in sensor resonance frequency. The biosensor demonstrates a linear shift in resonance frequency with staphylococcal enterotoxin B concentration between 0.5 and 5 ng/ml, with a detection limit of 0.5 ng/ml. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:585 / 591
页数:7
相关论文
共 50 条
  • [21] HETEROGENEITY OF STAPHYLOCOCCAL ENTEROTOXIN-B
    CHANG, PC
    DICKIE, N
    CANADIAN JOURNAL OF MICROBIOLOGY, 1971, 17 (11) : 1479 - &
  • [22] CHLORINATION OF STAPHYLOCOCCAL ENTEROTOXIN-B
    NISANJAN, PG
    ALEKSIEV, BV
    TERZIISK.GD
    DOKLADI NA BOLGARSKATA AKADEMIYA NA NAUKITE, 1973, 26 (04): : 509 - 512
  • [23] REGULATION OF STAPHYLOCOCCAL ENTEROTOXIN-B
    IANDOLO, JJ
    SHAFER, WM
    INFECTION AND IMMUNITY, 1977, 16 (02) : 610 - 616
  • [24] Laboratory exposures to Staphylococcal enterotoxin B
    Rusnak, JM
    Kortepeter, M
    Ulrich, R
    Poli, M
    Boudreau, E
    EMERGING INFECTIOUS DISEASES, 2004, 10 (09) : 1544 - 1549
  • [25] PURIFICATION OF TYPE B STAPHYLOCOCCAL ENTEROTOXIN
    FREA, JI
    STRONG, FM
    MCCOY, E
    JOURNAL OF BACTERIOLOGY, 1963, 86 (06) : 1308 - &
  • [26] Femtomolar detection of staphylococcal enterotoxin ?B? using a fluorescent quantum dot based hybrid Apta-immunosensor
    Chopra, Adity
    Swami, Anuradha
    Sharma, Rohit
    Devi, Neha
    Mittal, Sherry
    Sharma, Rohit K.
    Wangoo, Nishima
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 287
  • [28] Piezoelectric immunosensor for direct and rapid detection of staphylococcal enterotoxin A (SEA) at the ng level
    Salmain, Michele
    Ghasemi, Mahsa
    Boujday, Souhir
    Spadavecchia, Jolanda
    Techer, Clarisse
    Val, Florence
    Le Moigne, Vincent
    Gautier, Michel
    Briandet, Romain
    Pradier, Claire-Marie
    BIOSENSORS & BIOELECTRONICS, 2011, 29 (01): : 140 - 144
  • [30] Detection of staphylococcal enterotoxin C2 employing a piezoelectric crystal immunosensor
    Gao, ZX
    Chao, FH
    Chao, Z
    Li, GX
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 66 (1-3) : 193 - 196