Effect of Coracoid Drilling for Acromioclavicular Joint Reconstruction Techniques on Coracoid Fracture Risk: A Biomechanical Study

被引:51
|
作者
Martetschlaeger, Frank [1 ,2 ]
Saier, Tim [3 ,4 ]
Weigert, Annabelle [1 ]
Herbst, Elmar [1 ]
Winkler, Martin [4 ]
Henschel, Julia [4 ]
Augat, Peter [4 ,5 ]
Imhoff, Andreas B. [1 ]
Braun, Sepp [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Orthopaed Sports Med, Munich, Germany
[2] ATOS Clin Munich, Ctr Shoulder & Elbow Surg, Munich, Germany
[3] Berufsgenossenschaftl Klin Murnau, Trauma Ctr Murnau, Murnau, Germany
[4] Berufsgenossenschaftl Unfallklin Murnau, Inst Biomech, Murnau, Germany
[5] Paracelsus Med Univ, Inst Biomech, Salzburg, Austria
关键词
CORACOCLAVICULAR LIGAMENT RECONSTRUCTION; SEPARATIONS; CLAVICLE; COMPLICATIONS; DISLOCATIONS; REDUCTION; FIXATION;
D O I
10.1016/j.arthro.2015.11.049
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To biomechanically compare the stability of the coracoid process after an anatomic double-tunnel technique using two 4-mm drill holes or a single-tunnel technique using one 4-mm or one 2.4-mm drill hole. Methods: For biomechanical testing, 18 fresh-frozen cadaveric scapulae were used and randomly assigned to one of the following groups: two 4-mm drill holes (group 1), one 4-mm drill hole (group 2), or one 2.4-mm drill hole (group 3). After standardized coracoid drilling, load was applied to the conjoined tendons at a rate of 120 mm/min and ultimate failure load, along with the failure mode, was recorded. Results: There was no significant difference between groups regarding load to failure. Mean load to failure in group 1 was 392 N; group 2, 459 N; and group 3, 506 N. The corresponding P values were.55, .74, and .20 for group 1 versus group 2, group 2 versus group 3, and group 1 versus group 3, respectively. However, the failure mode for the group with one 4-mm drill hole and the group with two 4-mm drill holes was coracoid fracture, whereas the group with one 2.4-mm drill hole showed 5 tears of the conjoined tendons and only 1 coracoid fracture (P = .015). Conclusions: Although there was no significant difference regarding load-to-failure testing between groups, the failure mechanism analysis showed that one 2.4-mm drill hole led to less destabilization of the coracoid than one or two 4-mm drill holes.
引用
收藏
页码:982 / 987
页数:6
相关论文
共 50 条
  • [31] Risk for Fracture with Acromioclavicular Joint Reconstruction and Strategies for Mitigation
    Sachinis, Nikolaos Platon
    Beitzel, Knut
    [J]. CLINICS IN SPORTS MEDICINE, 2023, 42 (04) : 613 - 619
  • [32] Is the Position of Coracoid Button Important in Acromioclavicular Joint Dislocation Treatment with the Suture-Button?
    Gaweda, Krzysztof
    [J]. JOURNAL OF INVESTIGATIVE SURGERY, 2021, 34 (11) : 1262 - 1263
  • [33] Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study
    Yoshiteru Kawasaki
    Tetsuya Hirano
    Katsutoshi Miyatake
    Koji Fujii
    Yoshitsugu Takeda
    [J]. Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 913 - 918
  • [34] Comparing the Anatomical Landmarks Versus the Coracoid-Based Landmarks Techniques for Coracoclavicular Stabilization After High-Grade Acromioclavicular Injury: A Biomechanical Study
    Klabklay, Prapakorn
    Kwanyuang, Atichart
    Tangjatsakow, Preyanun
    Kala, Sataporn
    Suklim, Phachara
    Naknual, Nutnicha
    Chuaychoosakoon, Chaiwat
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2022, 10 (11)
  • [35] The “coracoid tunnel view”: a simulation study for finding the optimal screw trajectory in coracoid base fracture fixation
    C. H. van Trikt
    J. G. G. Dobbe
    J. C. E. Donders
    G. J. Streekstra
    P. Kloen
    [J]. Surgical and Radiologic Anatomy, 2019, 41 : 1337 - 1343
  • [36] The "coracoid tunnel view": a simulation study for finding the optimal screw trajectory in coracoid base fracture fixation
    van Trikt, C. H.
    Dobbe, J. G. G.
    Donders, J. C. E.
    Streekstra, G. J.
    Kloen, P.
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2019, 41 (11) : 1337 - 1343
  • [37] Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study
    Kawasaki, Yoshiteru
    Hirano, Tetsuya
    Miyatake, Katsutoshi
    Fujii, Koji
    Takeda, Yoshitsugu
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (07) : 913 - 918
  • [38] A biomechanical assessment of a novel double endobutton technique versus a coracoid cerclage sling for acromioclavicular and coracoclavicular injuries
    Grantham, Cori
    Heckmann, Nathanael
    Wang, Lawrence
    Tibone, James E.
    Struhl, Steven
    Lee, Thay Q.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (06) : 1918 - 1924
  • [39] Clavicle and coracoid process drilling technique for truly anatomic coracoclavicular ligament reconstruction
    Xue, Cheng
    Zhang, Ming
    Zheng, Tian-Sheng
    Zhang, Guo-Ying
    Fu, Peng
    Fang, Jia-Hu
    Li, Xiang
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (10): : 1314 - 1320
  • [40] AVULSION FRACTURE OF CORACOID EPIPHYSIS WITH ACROMIOCLAVICULAR SEPARATION - REPORT OF 2 CASES IN ADOLESCENTS AND REVIEW OF LITERATURE
    MONTGOMERY, SP
    LOYD, RD
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07): : 963 - 965