Effect of the AutoPulse™ automated band chest compression device on hemodynamics in out-of-hospital cardiac arrest resuscitation

被引:51
|
作者
Duchateau, Francois-Xavier [1 ]
Gueye, Papa [2 ]
Curac, Sonja [1 ]
Tubach, Florence [4 ]
Broche, Claire [2 ]
Plaisance, Patrick [3 ]
Payen, Didier [2 ]
Mantz, Jean [1 ]
Ricard-Hibon, Agnes [1 ]
机构
[1] Beaujon Univ Hosp, Dept Anaesthesiol & Intens Care, F-92110 Clichy, France
[2] Lariboisiere Univ Hosp, Dept Anesthesiol & Crit Care, Paris, France
[3] Lariboisiere Univ Hosp, Emergency Dept, Paris, France
[4] Bichat Claude Bernard Univ Hosp, Clin Res Unit, Paris, France
关键词
Hemodynamics; Cardiac arrest; Resuscitation; Out-of-hospital; CARDIOPULMONARY-RESUSCITATION; BLOOD-FLOW; PREDICTOR; QUALITY;
D O I
10.1007/s00134-010-1784-x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Guidelines for advanced life support of cardiac arrest (CA) emphasize continuous and effective chest compressions as one of the main factors of cardiopulmonary resuscitation (CPR) success. The use of an automated load distributing chest compression device for CPR is promising but initial studies on survival show contradictory results. The aim of this study was to evaluate the effects of AutoPulse (TM) on blood pressure (BP) in out-of-hospital CA patients. This prospective study included adult patients presenting with in refractory out-of-hospital CA. Invasive arterial BP produced by AutoPulse (TM) was compared to BP generated by manual CPR (Active Compression Decompression). Systolic, diastolic and mean BP and end-tidal carbon dioxide were recorded before and after initiating the automated band device for each patient. The comparison of diastolic BP produced by manual CPR versus automated chest compressions was the primary end point. Hemodynamics in 29 patients are reported and analyzed. Median diastolic BP increased after starting AutoPulse (TM) from 17[11-25] mmHg to 23[18-28] mmHg (P < 0.001). Median systolic BP increased from 72[55-105] mmHg to 106[78-135] mmHg (P = 0.02). Mean BP increased from 29[25-38] mmHg to 36[30-15] mmHg (P = 0.002). On the other hand, End-Tidal CO2 did not increase significantly with AutoPulse (TM) (21[13-36] vs. 22[12-35] mmHg, P = 0.80). In patients with out-of-hospital CA, the use of AutoPulse (TM) is associated with an increased diastolic BP compared to manual chest compressions. While its benefit to survival has yet to be demonstrated, the increase in diastolic and mean BP is a promising outcome for AutoPulse (TM) use.
引用
收藏
页码:1256 / 1260
页数:5
相关论文
共 50 条
  • [21] Comparison of chest compression only and standard cardiopulmonary resuscitation for out-of-hospital cardiac arrest in Singapore
    Ong, Marcus Eng Hock
    Ng, Faith Suan Peng
    Anushia, P.
    Tham, Lai Peng
    Leong, Benjamin Sieu-Hon
    Ong, Victor Yeok Kein
    Tiah, Ling
    Lim, Swee Han
    Anantharaman, V.
    RESUSCITATION, 2008, 78 (02) : 119 - 126
  • [22] Bystander chest compression-only cardiopulmonary resuscitation in children with out-of-hospital cardiac arrest
    Goto, Y.
    Funada, A.
    EUROPEAN HEART JOURNAL, 2018, 39 : 618 - 618
  • [24] Chest compression depth and survival in out-of-hospital cardiac arrest
    Vadeboncoeur, Tyler
    Stolz, Uwe
    Panchal, Ashish
    Silver, Annemarie
    Venuti, Mark
    Tobin, John
    Smith, Gary
    Nunez, Martha
    Karamooz, Madalyn
    Spaite, Daniel
    Bobrow, Bentley
    RESUSCITATION, 2014, 85 (02) : 182 - 188
  • [25] Dissemination of Chest Compression-Only Cardiopulmonary Resuscitation and Survival After Out-of-Hospital Cardiac Arrest
    Iwami, Taku
    Kitamura, Tetsuhisa
    Kiyohara, Kosuke
    Kawamura, Takashi
    CIRCULATION, 2015, 132 (05) : 415 - 422
  • [26] What Is the Optimal Chest Compression Depth During Out-of-Hospital Cardiac Arrest Resuscitation of Adult Patients?
    Stiell, Ian G.
    Brown, Siobhan P.
    Nichol, Graham
    Cheskes, Sheldon
    Vaillancourt, Christian
    Callaway, Clifton W.
    Morrison, Laurie J.
    Christenson, James
    Aufderheide, Tom P.
    Davis, Daniel P.
    Free, Cliff
    Hostler, Dave
    Stouffer, John A.
    Idris, Ahamed H.
    CIRCULATION, 2014, 130 (22) : 1962 - +
  • [27] Chest Compression Rates and Survival Following Out-of-Hospital Cardiac Arrest
    Idris, Ahamed H.
    Guffey, Danielle
    Pepe, Paul E.
    Brown, Siobhan P.
    Brooks, Steven C.
    Callaway, Clifton W.
    Christenson, Jim
    Davis, Daniel P.
    Daya, Mohamud R.
    Gray, Randal
    Kudenchuk, Peter J.
    Larsen, Jonathan
    Lin, Steve
    Menegazzi, James J.
    Sheehan, Kellie
    Sopko, George
    Stiell, Ian
    Nichol, Graham
    Aufderheide, Tom P.
    CRITICAL CARE MEDICINE, 2015, 43 (04) : 840 - 848
  • [28] What Affects Chest Compression Depth in Out-of-Hospital Cardiac Arrest?
    Russell, James K.
    Lupton, Joshua
    Leturiondo, Mikel
    Daya, Mohamud R.
    De Gauna, Sofia Ruiz
    CIRCULATION, 2023, 148
  • [29] Impact of automatic chest compression devices in out-of-hospital cardiac arrest
    Klosiewicz, Tomasz
    Puslecki, Mateusz
    Zalewski, Radoslaw
    Sip, Maciej
    Perek, Bartlomiej
    JOURNAL OF THORACIC DISEASE, 2020, 12 (05) : 2220 - 2227
  • [30] Continuous chest compression versus interrupted chest compression for cardiopulmonary resuscitation of non-asphyxial out-of-hospital cardiac arrest (Review)
    Zhan, Lei
    Yang, Li J.
    Huang, Yu
    He, Qing
    Liu, Guan J.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2017, (03):