Effect of the AutoPulse™ automated band chest compression device on hemodynamics in out-of-hospital cardiac arrest resuscitation

被引:51
|
作者
Duchateau, Francois-Xavier [1 ]
Gueye, Papa [2 ]
Curac, Sonja [1 ]
Tubach, Florence [4 ]
Broche, Claire [2 ]
Plaisance, Patrick [3 ]
Payen, Didier [2 ]
Mantz, Jean [1 ]
Ricard-Hibon, Agnes [1 ]
机构
[1] Beaujon Univ Hosp, Dept Anaesthesiol & Intens Care, F-92110 Clichy, France
[2] Lariboisiere Univ Hosp, Dept Anesthesiol & Crit Care, Paris, France
[3] Lariboisiere Univ Hosp, Emergency Dept, Paris, France
[4] Bichat Claude Bernard Univ Hosp, Clin Res Unit, Paris, France
关键词
Hemodynamics; Cardiac arrest; Resuscitation; Out-of-hospital; CARDIOPULMONARY-RESUSCITATION; BLOOD-FLOW; PREDICTOR; QUALITY;
D O I
10.1007/s00134-010-1784-x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Guidelines for advanced life support of cardiac arrest (CA) emphasize continuous and effective chest compressions as one of the main factors of cardiopulmonary resuscitation (CPR) success. The use of an automated load distributing chest compression device for CPR is promising but initial studies on survival show contradictory results. The aim of this study was to evaluate the effects of AutoPulse (TM) on blood pressure (BP) in out-of-hospital CA patients. This prospective study included adult patients presenting with in refractory out-of-hospital CA. Invasive arterial BP produced by AutoPulse (TM) was compared to BP generated by manual CPR (Active Compression Decompression). Systolic, diastolic and mean BP and end-tidal carbon dioxide were recorded before and after initiating the automated band device for each patient. The comparison of diastolic BP produced by manual CPR versus automated chest compressions was the primary end point. Hemodynamics in 29 patients are reported and analyzed. Median diastolic BP increased after starting AutoPulse (TM) from 17[11-25] mmHg to 23[18-28] mmHg (P < 0.001). Median systolic BP increased from 72[55-105] mmHg to 106[78-135] mmHg (P = 0.02). Mean BP increased from 29[25-38] mmHg to 36[30-15] mmHg (P = 0.002). On the other hand, End-Tidal CO2 did not increase significantly with AutoPulse (TM) (21[13-36] vs. 22[12-35] mmHg, P = 0.80). In patients with out-of-hospital CA, the use of AutoPulse (TM) is associated with an increased diastolic BP compared to manual chest compressions. While its benefit to survival has yet to be demonstrated, the increase in diastolic and mean BP is a promising outcome for AutoPulse (TM) use.
引用
收藏
页码:1256 / 1260
页数:5
相关论文
共 50 条
  • [1] Effect of the AutoPulse™ automated band chest compression device on hemodynamics in out-of-hospital cardiac arrest resuscitation
    François-Xavier Duchateau
    Papa Gueye
    Sonja Curac
    Florence Tubach
    Claire Broche
    Patrick Plaisance
    Didier Payen
    Jean Mantz
    Agnès Ricard-Hibon
    Intensive Care Medicine, 2010, 36 : 1256 - 1260
  • [2] Use of Autopulse (TM) automated band chest compression device in out-of-hospital cardiac arrest resuscitation: effect on hemodynamics
    Duchateau, F. -X.
    Gueye, P.
    Curac, S.
    Tubach, F.
    Broche, C.
    Plaisance, P.
    Payen, D.
    Mantz, J.
    Ricard-Hibon, A.
    ANNALES FRANCAISES DE MEDECINE D URGENCE, 2011, 1 (02): : 96 - 102
  • [3] Use of an automated, load-distributing band chest compression device for out-of-hospital cardiac arrest resuscitation
    Ong, Marcus Eng Hock
    Ornato, Joseph P.
    Edwards, David P.
    Dhindsa, Harinder S.
    Best, Al M.
    Ines, Caesar S.
    Hickey, Scott
    Clark, Bryan
    Williams, Dean C.
    Powell, Robert G.
    Overton, Jerry L.
    Peberdy, Mary Ann
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (22): : 2629 - 2637
  • [4] Clinical evaluation of the AutoPulse automated chest compression device for out-of-hospital cardiac arrest in the northern district of Shanghai, China
    Gao, Chengjin
    Chen, Yuanzhuo
    Peng, Hu
    Chen, Yanqing
    Zhuang, Yugang
    Zhou, Shuqin
    ARCHIVES OF MEDICAL SCIENCE, 2016, 12 (03) : 563 - 570
  • [5] EFFECT OF AUTOMATED SIMULTANEOUS STERNOTHORACIC CARDIOPULMONARY RESUSCITATION DEVICE ON HEMODYNAMICS IN OUT-OF-HOSPITAL CARDIAC ARREST PATIENTS
    Lee, Dong Keon
    Cha, Yong Sung
    Kim, Oh Hyun
    Cha, Kyoung Chul
    Lee, Kang Hyun
    Hwang, Sung Oh
    Kim, Hyun
    Lee, Young Hwan
    Chae, Minjung Kathy
    JOURNAL OF EMERGENCY MEDICINE, 2018, 55 (02): : 226 - 234
  • [6] Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest - A randomized trial
    Hallstrom, Al
    Rea, Thomas D.
    Sayre, Michael R.
    Christenson, James
    Anton, Andy R.
    Mosesso, Vince N., Jr.
    Van Ottingham, Lois
    Olsufka, Michele
    Pennington, Sarah
    White, Lynn J.
    Yahn, Stephen
    Husar, James
    Morris, Mary F.
    Cobb, Leonard A.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (22): : 2620 - 2628
  • [7] Causes of Chest Compression Interruptions During Out-of-Hospital Cardiac Arrest Resuscitation
    Hanisch, Jonathan R.
    Counts, Catherine R.
    Latimer, Andrew J.
    Rea, Thomas D.
    Yin, Lihua
    Sayre, Michael R.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (06):
  • [8] Continuous chest compression cardiopulmonary resuscitation following out-of-hospital cardiac arrest
    Carolyn M. Hui
    Peter G. Brindley
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2011, 58 : 330 - 333
  • [9] Continuous chest compression cardiopulmonary resuscitation following out-of-hospital cardiac arrest
    Hui, Carolyn M.
    Brindley, Peter G.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2011, 58 (03): : 330 - 333
  • [10] Out-of-hospital cardiopulmonary resuscitation with the AutoPulse™ system:: A prospective observational study with a new load-distributing band chest compression device
    Krep, Henning
    Mamier, Mathias
    Breil, Martin
    Heister, Ulrich
    Fischer, Matthias
    Hoeft, Andreas
    RESUSCITATION, 2007, 73 (01) : 86 - 95