Specific retention volumes in gas chromatography from low-quality capillary columns

被引:0
|
作者
Tello, AM [1 ]
García-Domínguez, JA [1 ]
机构
[1] CSIC, Inst Quim Fis Rocasolano, E-28006 Madrid, Spain
关键词
stationary phases; GC; retention volume; specific;
D O I
10.1016/S0021-9673(97)00899-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Specific retention volumes obtained from capillary columns of very low quality (column efficiencies about 100 theoretical plates/m), with a commercial polycyanopropylmethylsiloxane (50% substitution) as stationary phase, are compared with those obtained from the same type of columns and stationary phase, but exhibiting higher efficiencies. The statistical study shows that low-quality columns are as appropriate for measuring specific retention volumes as the better-quality columns. The same conclusion may be drawn for Kovats' retention indices or McReynolds' constants, if the aim of the study is the characterization of new stationary phases. (C) 1998 Elsevier Science B.V.
引用
下载
收藏
页码:383 / 389
页数:7
相关论文
共 50 条
  • [21] CAPILLARY PACKING COLUMNS IN GAS-CHROMATOGRAPHY
    BEREZKIN, VG
    SHKOLINA, LA
    LIPAVSKII, VN
    SERDAN, AA
    USPEKHI KHIMII, 1978, 47 (10) : 1875 - 1903
  • [22] WETTING PHENOMENA IN GAS CHROMATOGRAPHY CAPILLARY COLUMNS
    FARRERIUS, F
    GUIOCHON, G
    HENNIKER, J
    NATURE, 1962, 196 (4849) : 63 - &
  • [23] Permeability of monolithic capillary columns in gas chromatography
    Korolev, AA
    Popova, TP
    Shiryaeva, VE
    Kurganov, AA
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY, 2005, 79 (03): : 457 - 460
  • [24] CIRCULATION GAS-CHROMATOGRAPHY ON CAPILLARY COLUMNS
    STERKHOV, NV
    CHIZHKOV, VP
    INDUSTRIAL LABORATORY, 1991, 57 (01): : 1 - 11
  • [25] URINARY ORGANIC-ACIDS - RETENTION INDEXES ON 2 CAPILLARY GAS-CHROMATOGRAPHY COLUMNS
    WURTH, C
    KUMPS, A
    MARDENS, Y
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 491 (01): : 186 - 192
  • [26] PRECISION OF DETERMINING RETENTION VOLUMES FOR GASOLINE HYDROCARBONS IN ANALYSIS BY METHOD OF CAPILLARY GAS-LIQUID CHROMATOGRAPHY
    KULIKOV, VI
    KUZYAEVA, VV
    ZHURNAL ANALITICHESKOI KHIMII, 1973, 28 (08): : 1565 - 1570
  • [27] SOME FACTORS AFFECTING THE PRECISION IN THE DETERMINATION OF RETENTION INDEXES ON POLAR CAPILLARY COLUMNS FOR GAS-CHROMATOGRAPHY
    BEMGARD, A
    BLOMBERG, L
    JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01): : 37 - 52
  • [28] Loading capacities of monolithic capillary columns in gas chromatography
    Korolev, A. A.
    Popova, T. P.
    Shiryaeva, V. E.
    Kozin, A. V.
    Kurganov, A. A.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2007, 81 (03) : 469 - 474
  • [29] PULSE CIRCULATION GAS-CHROMATOGRAPHY ON CAPILLARY COLUMNS
    CHIZHKOV, VP
    PAVLOV, SS
    STERKHOV, NV
    RAVIKOVICH, VM
    LITVIN, EF
    VARYVONCHIK, EA
    TALANTA, 1987, 34 (01) : 227 - 229
  • [30] THE OPTIMUM OPERATION OF CAPILLARY COLUMNS IN GAS-CHROMATOGRAPHY
    OGAN, K
    SCOTT, RPW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 185 (MAR): : 98 - ANYL