Influence of oil-atomized air on flow and combustion characteristics in a 300 MWe down-fired boiler

被引:11
|
作者
Li, Zhengqi [1 ]
Ren, Feng [1 ]
Chen, Zhichao [1 ]
Wang, Jingjie [1 ]
Chen, Zhao [1 ]
Zhang, Juwei [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin 150001, Peoples R China
关键词
down-fired boiler; oil-atomized air; anthracite; coal burnout; NOx; VANE-SWIRLED FLAMES; TEMPERATURE; OPTIMIZATION; CHAR;
D O I
10.1002/apj.352
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A method of admitting oil-atomized air into a furnace to adjust coal combustion in a down-fired boiler is described. Experiments with a small-scale furnace simulating a down-fired, pulverized-coal, 300-MWe utility boiler were carried out at a single-phase test facility to investigate the influence of oil-atomized air on the aerodynamic field in the furnace. With the acceleration of oil by secondary air, the primary air/fuel can reach a more distant position with respect to the burner nozzle and the volume of the recirculation zone shrinks. Industrial experiments were also performed in a 300-MW, full-scale boiler. The gas temperature distribution along the primary air/fuel flow in the furnace and the gas components in the near-wall region were measured with the dampers of the oil-atomized air box open and closed. When open, the oil-atomized air does not impede the ignition of the primary air/fuel and can carry the primary air/fuel to a position much deeper in the furnace, resulting in a lowered carbon content in the fly ash. (c) 2009 Curtin University of Technology and John Wiley & Sons, Ltd.
引用
收藏
页码:488 / 496
页数:9
相关论文
共 50 条
  • [41] Flow-field deflection characteristics within a cold small-scale model for a down-fired 300 MWe utility boiler at different secondary-air angles
    Kuang, Min
    Li, Zhengqi
    Yang, Pengfei
    Jia, Jinzhao
    Zhu, Qunyi
    FUEL PROCESSING TECHNOLOGY, 2011, 92 (06) : 1261 - 1271
  • [42] Improving the combustion performance of a 660MWe down-fired utility boiler by adopting high efficiency combustion technologies
    Li, Zhengqi
    Liu, Guangkui
    Zhu, Qunyi
    Chen, Zhichao
    Ren, Feng
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [43] Effect of angle of arch-supplied overfire air on flow, combustion characteristics and NOx emissions of a down-fired utility boiler
    Li, Zhengqi
    Liu, Guangkui
    Chen, Zhichao
    Zeng, Lingyan
    Zhu, Qunyi
    ENERGY, 2013, 59 : 377 - 386
  • [44] Influence of the Staged-Air Declination Angle on Flow-Field Deflection in a Down-Fired Pulverized-Coal 300 MWe Utility Boiler with Direct-Flow Split Burners
    Kuang, Min
    Li, Zhengqi
    Han, Yunfeng
    Yang, Lianjie
    Zhu, Qunyi
    Zhang, Jia
    Shen, Shanping
    ENERGY & FUELS, 2010, 24 (03) : 1603 - 1610
  • [45] Effect of the separated overfire air location on the combustion optimization and NOx reduction of a 600 MWe FW down-fired utility boiler with a novel combustion system
    Ma, Lun
    Fang, Qingyan
    Tan, Peng
    Zhang, Cheng
    Chen, Gang
    Lv, Dangzhen
    Duan, Xuenong
    Chen, Yiping
    APPLIED ENERGY, 2016, 180 : 104 - 115
  • [46] Effect of the anthracite ratio of blended coals on the combustion and NOx emission characteristics of a retrofitted down-fired 660-MWe utility boiler
    Liu, Guangkui
    Li, Zhengqi
    Chen, Zhichao
    Zhu, Xingying
    Zhu, Qunyi
    APPLIED ENERGY, 2012, 95 : 196 - 201
  • [47] Influence of staged-air flow on flow characteristics in a scale model of a down-fired utility boiler with swirl burners: An experimental study
    Li, Zhengqi
    Fan, Subo
    Zhu, Qunyi
    Su, Wei
    Chen, Zhichao
    Qin, Yukun
    FUEL, 2012, 93 (01) : 160 - 166
  • [48] Influence of separated overfire-air parameters on combustion and NOx emission characteristics for a babcock & wilcox (B & W) down-fired boiler
    Wang K.
    Wang B.
    Yu J.
    Li M.
    Zhao F.
    Chen T.
    Zhang E.
    Sun L.
    Wang, Ben (benwang@hust.edu.cn), 2018, China Coal Society (43): : 839 - 845
  • [49] Impact of the Overfire Air Location on Combustion Improvement and NOx Abatement of a Down-Fired 350 MWe Utility Boiler with Multiple Injection and Multiple Staging
    Kuang, Min
    Li, Zhengqi
    Xu, Shantian
    Zhu, Xingying
    Zhang, Yan
    Zhu, Qunyi
    ENERGY & FUELS, 2011, 25 (10) : 4322 - 4332
  • [50] Flow-Field Deflection within a Cold Small-Scale Model for a Down-Fired 300 MWe Utility Boiler at Asymmetric Staged-Air Distribution
    Li, Zhengqi
    Kuang, Min
    Yang, Pengfei
    Zhu, Qunyi
    ENERGY & FUELS, 2011, 25 (01) : 86 - 96