X-ray Fluorescence Computed Tomography (XFCT) Imaging with a Superfine Pencil Beam X-ray Source

被引:6
|
作者
Romero, Ignacio O. [1 ]
Fang, Yile [1 ]
Lun, Michael [1 ]
Li, Changqing [1 ]
机构
[1] Univ Calif, Dept Bioengn, Merced, CA 95343 USA
关键词
X-ray fluorescence; computed tomography; GATE; Geant4; image reconstruction; X-ray imaging; NANOPARTICLE-LOADED OBJECTS;
D O I
10.3390/photonics8070236
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray fluorescence computed tomography (XFCT) is a molecular imaging technique that can be used to sense different elements or nanoparticle (NP) agents inside deep samples or tissues. However, XFCT has not been a popular molecular imaging tool because it has limited molecular sensitivity and spatial resolution. We present a benchtop XFCT imaging system in which a superfine pencil-beam X-ray source and a ring of X-ray spectrometers were simulated using GATE (Geant4 Application for Tomographic Emission) Monte Carlo software. An accelerated majorization minimization (MM) algorithm with an L-1 regularization scheme was used to reconstruct the XFCT image of molybdenum (Mo) NP targets. Good target localization was achieved with a DICE coefficient of 88.737%. The reconstructed signal of the targets was found to be proportional to the target concentrations if detector number, detector placement, and angular projection number are optimized. The MM algorithm performance was compared with the maximum likelihood expectation maximization (ML-EM) and filtered back projection (FBP) algorithms. Our results indicate that the MM algorithm is superior to the ML-EM and FBP algorithms. We found that the MM algorithm was able to reconstruct XFCT targets as small as 0.25 mm in diameter. We also found that measurements with three angular projections and a 20-detector ring are enough to reconstruct the XFCT images.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Ptychographic X-ray computed tomography at a high-brilliance X-ray source
    Sala, Simone
    Batey, Darren J.
    Prakash, Anupama
    Ahmed, Sharif
    Rau, Christoph
    Thibault, Pierre
    OPTICS EXPRESS, 2019, 27 (02): : 533 - 542
  • [32] X-ray computed tomography for medical imaging
    Hiriyannaiah, HP
    IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (02) : 42 - 59
  • [33] Radiation Dose Estimation for Small Animal Pencil Beam X-Ray Luminescence Computed Tomography Imaging
    Romero, I. O.
    Li, C.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [34] Preliminary Results On Benchtop X-Ray Fluorescence Computed Tomography (XFCT) Imaging of Gold Nanoparticle-Loaded Objects Using a Fully Spectroscopic Pixelated X-Ray Detector
    Ahmed, M. F.
    Jayarathna, S.
    O'Ryan, L.
    Cho, S. H.
    MEDICAL PHYSICS, 2019, 46 (06) : E301 - E301
  • [35] X-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13): : R29 - R43
  • [36] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    ELECTRONICS AND POWER, 1978, 24 (01): : 36 - 41
  • [37] X-ray computed tomography
    不详
    NATURE REVIEWS METHODS PRIMERS, 2021, 1 (01):
  • [38] X-ray computed tomography
    Nature Reviews Methods Primers, 1
  • [39] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    ELECTRONICS AND POWER, 1978, 24 (03): : 181 - 181
  • [40] Application of x-ray image magnifier and demagnifier to parallel beam x-ray computed tomography
    Hirano, K.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2011, 44 (05)