Impacts of Upstream Building Height and Stack Location on Pollutant Dispersion from a Rooftop Stack

被引:7
|
作者
Huang, Yuan-Dong [1 ]
Song, Ye [1 ]
Xu, Xuan [1 ]
He, Wen-Rong [1 ]
Kim, Chang-Nyung [2 ,3 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Environm & Architecture, Shanghai 200093, Peoples R China
[2] Kyung Hee Univ, Coll Engn, Yongin 449701, South Korea
[3] Kyung Hee Univ, Ind Liaison Res Inst, Yongin 449701, South Korea
基金
中国国家自然科学基金;
关键词
Pollutant dispersion; Airflow; Rooftop stack; Upstream building; Numerical simulation; WIND-TUNNEL; FIELD; ENVIRONMENT; SIMULATION;
D O I
10.4209/aaqr.2016.04.0151
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents Computational Fluid Dynamics (CFD) simulations to evaluate the impacts of the upstream building height and stack location on the dispersion of the pollutant released from a rooftop stack. The simulations are performed with the 3D, steady, Reynolds-Averaged Navier-Stokes (RANS) equations coupled with Realizable k-e turbulence model and the species transport equation. The flow development and pollutant dispersion are investigated numerically considering four different upstream building height (HB1) to emitting building height (HB2) ratios (HB1/HB2 = 0.5, 1.0, 2.0 and 3.6) and four different stack locations measured from the upwind edge of the emitting building (Xs) under the approaching wind perpendicular to the building faces. The results obtained reveal that: (1) the flow field characteristics around the buildings, especially the vortex flow above the emitting building roof and the vortex pattern between the upstream and emitting buildings, depend significantly on the upstream building height and much less on the location of the short stack; (2) for an upstream building of lower or equal height with the emitting building, the pollutants from a rooftop stack are immediately transported downwind the stack by the longitudinal flow; (3) when a stack is located inside the wake recirculation zone of the upstream building, the pollutants from the stack are swept by the upwind flow towards the leeward side of the upstream building and the distribution of pollutant concentrations is highly sensitive to both the upstream building height and the stack location. For different upstream building heights, suitable locations for fresh air intakes on the sides of buildings are also proposed based on the pollutant distribution patterns obtained.
引用
下载
收藏
页码:1837 / 1855
页数:19
相关论文
共 50 条
  • [21] Effects of a rooftop wind turbine on the dispersion of air pollutant behind a cube-shaped building
    Shuaibin Zhang
    Haoze Yang
    Bowen Du
    Mingwei Ge
    Theoretical & Applied Mechanics Letters, 2021, 11 (05) : 296 - 303
  • [22] Tracer gas experiment to verify the dispersion from a tall stack
    Sivertsen, B
    Irwin, JS
    NINTH JOINT CONFERENCE ON APPLICATIONS OF AIR POLLUTION METEOROLOGY WITH A&WMA, 1996, : 41 - 45
  • [23] Effect of pollutant source location on air pollutant dispersion around a high-rise building
    Keshavarzian, Erfan
    Jin, Ruizhi
    Dong, Kejun
    Kwok, Kenny C. S.
    Zhang, Yu
    Zhao, Ming
    APPLIED MATHEMATICAL MODELLING, 2020, 81 (81) : 582 - 602
  • [24] BUILDING HEIGHT EXTRACTION VIA A DETERMINISTIC APPROACH USING A TERRASAR-X DATA STACK
    Liu, Kang
    Balz, Timo
    Liao, Mingsheng
    2010 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2010, : 2920 - 2923
  • [25] Numerical simulation of atmospheric flow and stack gas diffusion under building and complex terrain conditions (Estimations of effective stack height and comparisons with wind tunnel experiments)
    Sada, K
    Michioka, T
    Ichikawa, Y
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2006, 49 (01) : 48 - 59
  • [26] Formation and dispersion of nitric acid vapor from stack flue gas
    Park M.J.
    Wu S.C.
    Jo Y.M.
    Park Y.K.
    Asian Journal of Atmospheric Environment, 2014, 8 (2) : 96 - 107
  • [27] Assessment of pollutant dispersion from rooftop stacks: ASHRAE, ADMS and wind tunnel simulation
    Hajra, B.
    Stathopoulos, T.
    Bahloul, A.
    BUILDING AND ENVIRONMENT, 2010, 45 (12) : 2768 - 2777
  • [28] Effects of increasing the degree of building height asymmetry on ventilation and pollutant dispersion within street canyons
    Jon K.S.
    Jong S.I.
    Ri S.H.
    Ko J.Y.
    Ko S.G.
    Kim H.
    Ryang T.S.
    Sin C.H.
    Energy and Built Environment, 2024, 5 (05): : 727 - 740
  • [29] The effect of ganging on pollutant dispersion from building exhaust stacks
    Petersen, R. L.
    Reifschneider, J. D.
    ASHRAE TRANSACTIONS 2008, VOL 114, PT 1, 2008, 114 : 458 - 470