Right-to-left shunt assessed by contrast transcranial Doppler sonography - New insights

被引:15
|
作者
Uzuner, N [1 ]
Horner, S
Pichler, G
Svetina, D
Niederkorn, K
机构
[1] Osmangazi Univ, Sch Med, Dept Neurol, TR-26480 Eskisehir, Turkey
[2] Landeskrankenhaus Graz Univ, Dept Neurol, Graz, Austria
关键词
cerebrovascular disease; patent foramen ovale; sonography; transcranial Doppler sonography;
D O I
10.7863/jum.2004.23.11.1475
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
objective. Simple diagnostic techniques such as contrast transcranial Doppler sonography (cTCDS) are popular for assessing a right-to-left shunt (RLS) because of their high sensitivity In this study, we applied cTCDS to a large patient group with a patent foramen ovale, proved by contrast transesophageal echocardiography (TEE). Methods. One hundred one patients with stroke, in whom a patent RLS had been shown on contrast TEE, were investigated by TCDS of both middle cerebral arteries. Injection of 10 mL of agitated saline was applied without and subsequently with the Valsalva maneuver (VM) at the beginning of the contrast agent injection, and then 10 mL of a galacto,se-based contrast agent was applied in the same protocol. Results. In all patients, cTCDS with the galactose contrast agent showed an RLS when performed with VM, but it showed an RLS in only 59 patients without VM. In contrast, saline showed an RLS in 54 patients with VM and in 20 patients without VM. The differences in diagnostic sensitivity were statistically significant (P < .001). Eighteen patients had only 1 microembolic signal (MES) after galactose injection, whereas others had more. The mean (SD) arrival times of the MES were 9 (6) seconds (range, 1-51 seconds) after galactose injection with VM and 9 (3) seconds (range, 2-20 seconds) after agitated saline with VM. The differences were not significant. Conclusions. Contrast TCDS with VM shows a TEE-proven RLS with 100% sensitivity, but this was not true with galactose application without VM or agitated saline with or without VM. Therefore, use of the galactose contrast agent with VM is strongly recommended for detecting an RLS on TCDS. However, the arrival time and number of MESs detected need to be tested further.
引用
收藏
页码:1475 / 1482
页数:8
相关论文
共 50 条
  • [21] Sensitivity of Transcranial Doppler Versus Intracardiac Echocardiography in the Detection of Right-to-Left Shunt
    Van, HoHai
    Poommipanit, Paul
    Shalaby, Mostafa
    Gevorgyan, Rubine
    Tseng, Chi-Hong
    Tobis, Jonathan
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (04) : 343 - 348
  • [22] Transcranial Doppler to detect right-to-left shunt in cryptogenic acute ischemic stroke
    Palazzo, Paola
    Ingrand, Pierre
    Agius, Pierre
    Chaidi, Rafik Belhadj
    Neau, Jean-Philippe
    BRAIN AND BEHAVIOR, 2019, 9 (01):
  • [23] Alternatives to transtemporal approach of transcranial Doppler for the detection of right-to-left cardiac shunt
    Sharma, Vijay K.
    Teoh, Hock L.
    Chan, Bernard P. L.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2009, 279 (1-2) : 124 - 125
  • [24] Enhanced detection of right-to-left shunt by transcranial doppler: Comparison of various maneuvers
    Selim, Magdy H.
    LaFrance, Casey
    STROKE, 2007, 38 (02) : 491 - 491
  • [25] Detection of Right-to-Left Shunt With Transcranial Doppler Is Affected by Body-Positioning
    Tsivgoulis, Georgios
    Sharma, Vijay K.
    Alexandrov, Andrei V.
    STROKE, 2008, 39 (11) : E184 - E184
  • [26] The RoPE Score and Right-to-Left Shunt Severity by Transcranial Doppler in the CODICIA Study
    Wessler, Benjamin S.
    Kent, David M.
    Thaler, David E.
    Ruthazer, Robin
    Lutz, Jennifer S.
    Serena, Joaquin
    CEREBROVASCULAR DISEASES, 2015, 40 (1-2) : 52 - 58
  • [27] COMPARISON OF DIFFERENT METHODS OF VALSALVA MANEUVER FOR RIGHT-TO-LEFT SHUNT DETECTION BY CONTRAST-ENHANCED TRANSCRANIAL DOPPLER
    Guo, Yu-Zhu
    Gao, Yong-Sheng
    Guo, Zhen-Ni
    Niu, Peng-Peng
    Yang, Yi
    Xing, Ying-Qi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (05): : 1124 - 1129
  • [28] Saline versus Saline with Blood as a Contrast Agent for Right-to-left Shunt Diagnosis by Transcranial Doppler: Is There a Significant Difference?
    Lange, Marcos Christiano
    Zetola, Viviane Flumignan
    Piovesan, Elcio J.
    Werneck, Lineu Cesar
    JOURNAL OF NEUROIMAGING, 2012, 22 (01) : 17 - 20
  • [29] Posture-dependence of right-to-left shunt across the patent foramen ovale: A contrast transcranial Doppler evaluation
    Anzola, Gian Paoio
    Berti, Marco
    Casilli, Francesco
    Onorato, Eustaquio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B72 - B72
  • [30] Migraine induction by brain micro-embolization during contrast transcranial Doppler evaluation of right-to-left shunt
    Sorensen, SG
    Davis, DL
    Raleigh, L
    Aguilar, H
    Casterella, PJ
    Ronnow, BS
    Choucair, AK
    Lappé, DL
    Thomas, H
    Muhlestein, JB
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 91H - 92H