Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty

被引:3
|
作者
Anwander, H. [1 ,2 ]
Cron, G. O. [1 ,3 ]
Rakhra, K. [1 ,3 ]
Beaule, P. E. [1 ,4 ]
机构
[1] Univ Ottawa, Ottawa Hosp, 501 Smyth Rd, Ottawa, ON, Canada
[2] Univ Orthopad Chirurg & Traumatol, Freiburgstr 4, CH-3010 Bern, Switzerland
[3] Univ Ottawa, Ottawa Hosp, Dept Med Imaging, 501 Smyth Rd, Ottawa, ON, Canada
[4] Univ Ottawa, Ottawa Hosp, Div Orthopaed Surg, 501 Smyth Rd, Ottawa, ON, Canada
来源
BONE & JOINT RESEARCH | 2016年 / 5卷 / 03期
关键词
metal-on-metal total hip arthroplasty; dynamic contrast-enhanced magnetic resonance imaging; DCE-MRI; Ktrans; CONTRAST-ENHANCED MRI; LOCAL TISSUE-REACTIONS; ASYMPTOMATIC PATIENTS; BLOOD-FLOW; PSEUDOTUMORS; REPLACEMENT; PROSTHESES; BEARINGS; GENDER; THA;
D O I
10.1302/2046-3758.53.2000572
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Objectives Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volume transfer constant of contrast agent). Our purpose was 1) to evaluate the feasibility of DCE-MRI in patients with THA and 2) to compare DCE-MRI in patients with MoM bearings with metal-on-polyethylene (MoP) bearings, hypothesising that the perfusion index Ktrans in hips with MoM THA is higher than in hips with MoP THA. Methods In this pilot study, 16 patients with primary THA were recruited (eight MoM, eight MoP). DCE-MRI of the hip was performed at 1.5 Tesla (T). For each patient, Ktrans was computed voxel-by-voxel in all tissue lateral to the bladder. The mean Ktrans for all voxels was then calculated. These values were compared with respect to implant type and gender, and further correlated with clinical parameters. Results There was no significant difference between the two bearing types with both genders combined. However, dividing patients by THA bearing and gender, women with MoM bearings had the highest Ktrans values, exceeding those of women with MoP bearings (0.067 min(-1) versus 0.053 min(-1); p-value < 0.05) and men with MoM bearings (0.067 min(-1) versus 0.034 min(-1); p-value < 0.001). Considering only the men, patients with MoM bearings had lower Ktrans than those with MoP bearings (0.034 min(-1) versus 0.046 min(-1); p < 0.05). Conclusion DCE-MRI is feasible to perform in tissues surrounding THA. Females with MoM THA show high Ktrans values in DCE-MRI, suggesting altered tissue perfusion kinematics which may reflect relatively greater inflammation.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 50 条
  • [11] Bearing surfaces for total disc arthroplasty: metal-on-metal versus metal-on-polyethylene and other biomaterials
    Golish, S. Raymond
    Anderson, Paul A.
    [J]. SPINE JOURNAL, 2012, 12 (08): : 693 - 701
  • [12] Metal-on-Metal Total Hip Arthroplasty
    Kim, Raymond H.
    Dennis, Douglas A.
    Carothers, Joshua T.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 44 - 46
  • [13] Metal-on-Metal Total Hip Arthroplasty
    Malviya, Ajay
    Ramaskandhan, Jayasree
    Holland, James P.
    Lingard, Elizabeth A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (07): : 1675 - 1683
  • [14] Pseudotumor Associated With Metal-on-Polyethylene Total Hip Arthroplasty
    Scully, Cpt William F.
    Teeny, Steven M.
    [J]. ORTHOPEDICS, 2013, 36 (05) : E666 - E670
  • [15] Material loss at the femoral head taper A COMPARISON STUDY OF THE EXETER METAL-ON-POLYETHYLENE AND CONTEMPORARY METAL-ON-METAL TOTAL HIP ARTHROPLASTY
    Langton, D. J.
    Wells, S. R.
    Joyce, T. J.
    Bowsher, J. G.
    Deehan, D.
    Green, S.
    Nargol, A. V. F.
    Holland, J. P.
    [J]. BONE & JOINT JOURNAL, 2018, 100B (10): : 1310 - 1319
  • [16] Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty-MRI versus ultrasonography performed by an orthopedic surgery resident
    Mikkelsen, Rasmus T.
    Schou, Martin
    Torfing, Trine
    Graumann, Ole
    Overgaard, Soren
    Varnum, Claus
    [J]. ACTA RADIOLOGICA OPEN, 2023, 12 (02)
  • [17] Outcome of Re-Revision Surgery for Adverse Local Tissue Reaction in Metal-on-Polyethylene and Metal-on-Metal Total Hip Arthroplasty
    Bonner, Bryant
    Arauz, Paul
    Klemt, Christian
    Kwon, Young-Min
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (06): : S284 - S288
  • [18] Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results
    Zijlstra, Wierd P.
    van der Veen, Hugo C.
    van den Akker-Scheek, Inge
    Zee, Mark J. M.
    Bulstra, Sjoerd K.
    van Raay, Jos J. A. M.
    [J]. HIP INTERNATIONAL, 2014, 24 (02) : 136 - 143
  • [19] Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial
    Wierd P Zijlstra
    Nanne Bos
    Jos JAM van Raaij
    [J]. BMC Musculoskeletal Disorders, 9
  • [20] Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial
    Zijlstra, Wierd P.
    Bos, Nanne
    van Raaij, Jos J. A. M.
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2008, 9 (1)