Loop mediated isothermal amplification of Clostridioides difficile isolates in gastrointestinal patients

被引:3
|
作者
Moosavian, Mojtaba [1 ]
Keshavarzi, Razieyeh [2 ]
Abbasi Montazeri, Effat [1 ,2 ]
Hajiani, Eskandar [3 ]
机构
[1] Ahvaz Jundishapur Univ Med Sci, Hlth Res Inst, Infect & Trop Dis Res Ctr, Ahvaz, Iran
[2] Ahvaz Jundishapur Univ Med Sci, Dept Microbiol, Fac Med, Ahvaz, Iran
[3] Ahvaz Jundishapur Univ Med Sci, Dept Internal Med, Div Gastroenterol & Hepatol, Ahvaz, Iran
关键词
LAMP assay; PCR; Culture; Clostridioides difficile; tcdA; tcdB; INFECTION; PCR; DIAGNOSIS; TOXIN; EPIDEMIOLOGY; PREVALENCE; SPECIMENS; ADULTS; ASSAY; LAMP;
D O I
10.1186/s13568-022-01382-1
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This study investigated the prevalence of Clostridioides difficile by culture, multiplex polymerase chain reaction (M-PCR), and loop mediated isothermal amplification (LAMP) in patients with suspected C. difficile infections (CDIs). Also, the results of three methods were compared. All stool specimens collected from CDI suspected patients were cultured on selective C. difficile cycloserine-cefoxitin fructose agar and incubated in an anaerobic jar up to 7 days. The bacterial isolates were identified using standard tests. Multiplex-PCR (M-PCR) was performed for detection of tcdA, tcdB, and tpi genes. The LAMP assay was performed to detect the tcdB gene of C. difficile. C. difficile was isolated from 20.0% (n = 10/50) of samples by culture. M-PCR showed that 34.0% (n = 17/50) of the specimens were positive for C. difficile based on the presence of tpi gene. Out of the 17 C. difficile, 13 strains (76.0%) were positive for tcdB gene using M-PCR. However, the LAMP assay showed that 30.0% (15/50) of specimens were positive for the presence of tcdB gene. M-PCR and LAMP methods showed 100.0% sensitivity compared to the culture method. However, the specificity of the LAMP (87.5%) was relatively higher than the M-PCR (82.5%) compared to the culture. Based on the results of this study, the prevalence of toxigenic C. difficile strains was high in suspected CDI patients. So, the differentiation between toxigenic and non-toxigenic strains is necessary. Our data showed that the LAMP assay is a good method for direct detection of toxigenic C. difficile strains from stool specimens.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Detecting amplicons of loop-mediated isothermal amplification
    Shirato, Kazuya
    MICROBIOLOGY AND IMMUNOLOGY, 2019, 63 (10) : 407 - 412
  • [22] Applications of Loop-Mediated Isothermal DNA Amplification
    Fu, Shijun
    Qu, Guanggang
    Guo, Shijin
    Ma, Lin
    Zhang, Na
    Zhang, Songlin
    Gao, Sanyang
    Shen, Zhiqiang
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2011, 163 (07) : 845 - 850
  • [23] Loop-Mediated Isothermal Amplification Test Method Compared With Enzyme Immunoassay Method for Clostridium difficile Diagnosis
    Morong, Dawn
    Piper, Donald
    Dragoni, Catherine
    Ianosi-Irimie, Monica
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 : A060 - A060
  • [24] Applications of Loop-Mediated Isothermal DNA Amplification
    Shijun Fu
    Guanggang Qu
    Shijin Guo
    Lin Ma
    Na Zhang
    Songlin Zhang
    Sanyang Gao
    Zhiqiang Shen
    Applied Biochemistry and Biotechnology, 2011, 163 : 845 - 850
  • [25] Evaluation of the rapid loop-mediated isothermal amplification assay Illumigene for diagnosis of Clostridium difficile in an outbreak situation
    Noren, Torbjorn
    Unemo, Magnus
    Magnusson, Cecilia
    Eiserman, Maud
    Matussek, Andreas
    APMIS, 2014, 122 (02) : 155 - 160
  • [26] Loop mediated isothermal amplification: An innovative gene amplification technique for animal diseases
    Sahoo, Pravas Ranjan
    Sethy, Kamadev
    Mohapatra, Swagat
    Panda, Debasis
    VETERINARY WORLD, 2016, 9 (05) : 465 - 469
  • [27] Evaluation of three enzyme immunoassays and a loop-mediated isothermal amplification test for the laboratory diagnosis of Clostridium difficile infection
    Bruins, M. J.
    Verbeek, E.
    Wallinga, J. A.
    van Coppenraet, L. E. S. Bruijnesteijn
    Kuijper, E. J.
    Bloembergen, P.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2012, 31 (11) : 3035 - 3039
  • [28] ILLUMIGENE LOOP MEDIATED ISOTHERMAL AMPLIFICATION ASSAY: A SENSITIVE ASSAY FOR DETECTING TOXIN PRODUCING CLOSTRIDIUM DIFFICILE IN SECOND LINE
    Poesen, Koen
    Colaert, Johan
    Boudewijns, Michael
    ACTA CLINICA BELGICA, 2012, 67 (01): : 64 - 64
  • [29] Loop-Mediated Isothermal Amplification for the Rapid Detection of the Mutation of Carbendazim-Resistant Isolates in Didymella bryoniae
    Shen, Lina
    Huang, Mengyu
    Fang, Anfei
    Yang, Yuheng
    Yu, Yang
    Bi, Chaowei
    AGRONOMY-BASEL, 2022, 12 (09):
  • [30] Evaluation of three enzyme immunoassays and a loop-mediated isothermal amplification test for the laboratory diagnosis of Clostridium difficile infection
    M. J. Bruins
    E. Verbeek
    J. A. Wallinga
    L. E. S. Bruijnesteijn van Coppenraet
    E. J. Kuijper
    P. Bloembergen
    European Journal of Clinical Microbiology & Infectious Diseases, 2012, 31 : 3035 - 3039