Treating lung cancer with dynamic conformal arc therapy: a dosimetric study

被引:7
|
作者
Peterlin, Primoz [1 ]
Stanic, Karmen [1 ]
Mendez, Ignasi [1 ]
Strojnik, Andrej [1 ]
机构
[1] Inst Oncol Ljubljana, Zaloska 2, SI-1000 Ljubljana, Slovenia
关键词
Dynamic conformal arc therapy; Film dosimetry; Lung cancer; VOLUMETRIC-MODULATED ARC; RADIATION PNEUMONITIS; STATISTICAL-ANALYSIS; IMRT; RADIOTHERAPY; MOTION; TOXICITY; SBRT;
D O I
10.1186/s13014-017-0823-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Lung cancer patients are often in poor physical condition, and a shorter treatment time would reduce their discomfort. Dynamic conformal arc therapy (DCAT) offers a shorter treatment time than conventional 3D conformal radiotherapy (3D CRT) and is usually available even in departments without inverse planning possibilities. We examined its suitability as a treatment modality for lung cancer patients. Methods: On a cohort of 35 lung cancer patients, relevant dosimetric parameters were compared in respective DCAT and 3D CRT treatment plans. Radiochromic film dosimetry in an anthropomorphic phantom was used to compare both DCAT and 3D CRT dose distributions against their planned counterparts. Results: In comparison with their 3D CRT counterparts, DCAT plans equal or exceed the agreement between the calculated dose and the dose measured using film dosimetry. In dosimetric comparison, DCAT performed significantly better than 3D CRT in dose conformity to PTV and the number of monitor units used per plan, and significantly worse in dose homogeneity, mean lung dose and lung volume exposed to 5 Gy or more (V5Gy). No significant difference was found in the V20Gy value to lung, dose to 1 cm(3) of spinal cord, and the mean dose to oesophagus. Improvements in V20Gy and V5Gy were found to be negatively correlated. DCAT plans differ from 3D CRT by exhibiting a moderate negative correlation between target volume sphericity and dose homogeneity. Conclusions: With respect to the agreement between the planned and the irradiated dose distribution, DCAT appears at least as reliable as 3D CRT. In specific conditions concerning the patient anatomy and treatment prescription, DCAT may yield more favourable dosimetric parameters. On average, however, conventional 3D CRT usually obtains better dosimetric parameters. We can thus only recommend DCAT as a complementary technique to the conventional 3D CRT.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Treating lung cancer with dynamic conformal arc therapy: a dosimetric study
    Primož Peterlin
    Karmen Stanič
    Ignasi Méndez
    Andrej Strojnik
    [J]. Radiation Oncology, 12
  • [2] A dosimetric study of dynamic conformal arc therapy for lung cancer
    Cho, N. K.
    Maxim, P. G.
    Loo, B. W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S687 - S687
  • [3] Comparative study of dynamic conformal arc therapy and volumetric modulated arc therapy for treating single brain metastases: A retrospective analysis of dosimetric and clinical outcomes
    Chambrelant, Isabelle
    Jarnet, Delphine
    Le Fevre, Clara
    Kuntz, Laure
    Jacob, Julian
    Jenny, Catherine
    Noe, Georges
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 30
  • [4] The dosimetric effect of inhomogeneity correction in dynamic conformal arc stereotactic body radiation therapy for lung tumors
    Kavanagh, Brian
    Ding, Meisong
    Schefter, Tracey
    Stuhr, Kelly
    Newman, Francis
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (02): : 58 - 63
  • [5] A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT
    Stathakis, Sotirios
    Narayanasamy, Ganesh
    Licon, Anna Laura
    Myers, Pamela
    Li, Ying
    Crownover, Richard
    Papanikolaou, Niko
    [J]. JOURNAL OF BUON, 2019, 24 (02): : 838 - 843
  • [6] Dynamic Conformal Arc Therapy for Lung and Liver SBRT
    Stathakis, S.
    Licon, A.
    Saenz, D.
    Kirby, N.
    Rasmussen, K.
    Crownover, R.
    Li, Y.
    Mavroidis, P.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E338 - E338
  • [7] Evaluation of the hybrid-dynamic conformal arc therapy technique for radiotherapy of lung cancer
    Kim, Sung Joon
    Lee, Jeong Won
    Kang, Min Kyu
    Kim, Jae-Chul
    Lee, Jeong Eun
    Park, Shin-Hyung
    Kim, Mi Young
    Lee, Seoung-Jun
    Moon, Soo-Ho
    Ko, Byoung-Soo
    [J]. RADIATION ONCOLOGY JOURNAL, 2018, 36 (03): : 241 - 247
  • [8] 4π Dynamic Conformal Arc Therapy Dynamic Conformal Arc Therapy (DCAT) for SBRT
    Chiu, T.
    Long, T.
    Modiri, A.
    Tian, Z.
    Sawant, A.
    Yan, Y.
    Jiang, S.
    Gu, X.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3895 - 3895
  • [9] Comparison of the Dosimetric Planning Efficiency of Dynamic Conformal Arc and Volumetric Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Cancer Using Internal Target Volume
    Saglam, Yucel
    [J]. JOURNAL OF CLINICAL PRACTICE AND RESEARCH, 2023, 45 (01): : 19 - 24
  • [10] Comparison of the Dosimetric Planning Efficiency of Dynamic Conformal Arc and Volumetric Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Cancer Using Internal Target Volume
    Saglam, Yuecel
    [J]. ERCIYES MEDICAL JOURNAL, 2023, 45 (01) : 19 - 24