H∞ control of a three-phase shunt active filter:: An LMI approach

被引:0
|
作者
Al Chaer, Toufic [1 ,2 ]
Rambault, Laurent [1 ]
Gaubert, Jean-Paul [1 ]
Najjar, Maged [2 ]
机构
[1] LAII, 40 Ave Recteur, F-86022 Poitiers, France
[2] Univ Balamand, Dept Elect Engn, Tripoli, Lebanon
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The main objective of this work is to synthesize a robust static state feedback controller capable of controlling an active power filter connected in parallel to a three-phase voltage distribution system. A shunt active filter is used to improve power quality by eliminating harmonic distortion generated by non-linear loads. The open-loop system is described, in a complex frame, by a linear state space representation with complex-valued parameters. The synthesis of such controller is performed using H-infinity robust control based on a Linear Matrix Inequality (LMI) approach.
引用
收藏
页码:675 / 680
页数:6
相关论文
共 50 条
  • [21] Energy control of three-phase four-wire shunt active power filter
    Rodríguez, P
    Pindado, R
    Pou, J
    [J]. IECON'03: THE 29TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1 - 3, PROCEEDINGS, 2003, : 1061 - 1066
  • [22] A Lyapunov-Function-Based Control for a Three-Phase Shunt Hybrid Active Filter
    Rahmani, Salem
    Hamadi, Abdelhamid
    Al-Haddad, Kamal
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (03) : 1418 - 1429
  • [23] H∞ control design methodology for a three-phase active power filter
    Al Chaer, Totific
    Rambault, Laurent
    Gaubert, Jean-Paul
    Najjar, Maged
    [J]. 2007 AMERICAN CONTROL CONFERENCE, VOLS 1-13, 2007, : 929 - +
  • [24] Application of Adaptive Fuzzy Control in Three-Phase Three-Wire Shunt Active Power Filter
    Xu Changbo
    Wang Rongrong
    Li Chunwen
    [J]. PROCEEDINGS OF THE 27TH CHINESE CONTROL CONFERENCE, VOL 4, 2008, : 402 - 405
  • [25] Control scheme for three-phase three-wire shunt active power filter with unbalanced loads
    Wei, Xue-Liang
    Dai, Ke
    Xie, Bin
    Kang, Yong
    Peng, Hua-Liang
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2008, 28 (24): : 64 - 69
  • [26] Simulation of Three-phase Three-wire Shunt Active Power Filter
    Wang, Jidong
    [J]. 2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 278 - 281
  • [27] A shunt active filter control for one-phase and three-phase four-wire systems
    Dell'Aquila, A
    Lecci, A
    [J]. ISIE 2002: PROCEEDINGS OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-4, 2002, : 1301 - 1305
  • [28] Phase-angle balance control for harmonic filtering of a three-phase shunt active filter system
    Chattopadhyay, S
    Ramanarayanan, V
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (02) : 565 - 574
  • [29] Application of an LLCL Filter on Three-Phase Three-Wire Shunt Active Power Filter
    Liu, Cong
    Dai, Ke
    Duan, Kewei
    Wang, Xin
    Kang, Yong
    [J]. 2012 IEEE 34TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2012,
  • [30] THREE-PHASE SHUNT ACTIVE POWER FILTER BASED ON THE INTERCONNECTION OF SINGLE-PHASE AND THREE-PHASE CONVERTERS
    Maciel, A. M.
    Jacobina, C. B.
    Melo, V. B.
    dos Santos, E. C., Jr.
    Fahricio, E. L. L.
    [J]. 2013 BRAZILIAN POWER ELECTRONICS CONFERENCE (COBEP), 2013, : 1239 - 1244