Intra-rater and inter-rater reliability, minimal detectable change, and construct validity of the Edinburgh Visual Gait Score in children with cerebral palsy

被引:1
|
作者
Abe, Hirokazu [1 ,5 ]
Koyanagi, Shotaro [2 ]
Kusumoto, Yasuaki [3 ]
Himuro, Nobuaki [4 ]
机构
[1] Saitama Childrens Med Ctr, Dept Hlth Care & Child Dev, Saitama, Japan
[2] Visiting Nursing Stn Asuka, Dept Rehabil, Hiroshima, Japan
[3] Fukushima Med Univ Sch Hlth Sci, Dept Phys Therapy, Fukushima, Japan
[4] Sapporo Med Univ, Sch Med, Dept Publ Hlth, Sapporo, Japan
[5] Saitama Childrens Med Ctr, Dept Hlth Care & Child Dev, 1-2,Shintoshin,Chuo Ku, Saitama, Saitama 3308777, Japan
关键词
Cerebral palsy; Observational gait assessment; Gross Motor Function Measure; Minimal detectable change; BOTULINUM-TOXIN-A; GMFCS LEVELS I; MULTILEVEL SURGERY; MANAGEMENT; QUALITY; INDEX; KNEE;
D O I
10.1016/j.gaitpost.2022.03.004
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: The Edinburgh Visual Gait Score (EVGS) has been used for observational gait assessment in children with cerebral palsy (CP). However, the measurement error of the EVGS and its detailed relationship with gross motor function remain unclear. Research questions: This study aimed to confirm the intra-rater and inter-rater reliability as well as the minimal detectable change (MDC) values for the EVGS with the use of the video analysis software and examine the relationship between the EVGS and the Gross Motor Function Measure 66 (GMFM-66) with regard to construct validity. Methods: This cross-sectional study was conducted for 62 children (mean age 11.3 +/- 3.9 years) with spastic CP at Gross Motor Function Classification System (GMFCS) level I (32 children), II (25 children) or III (5 children). Three raters independently scored the EVGS using Kinovea video analysis software. The intra-rater and inter rater reliability were calculated using intra-class correlation coefficients (ICC2,1), and the MDC90 was calculated using standard error of measurement. The construct validity was examined by correlating the EVGS with the GMFM-66. Results: The EVGS showed good or excellent reliability within each rater (ICC2,1 = 0.90-0.97) and between raters (ICC2,1 = 0.91). The MDC90 of the EVGS ranged from 3.6 to 6.0. There was a significant correlation between the EVGS and the GMFM-66 (r = 0.69 to 0.73, p < 0.001). Significance: The intra-rater and inter-rater reliability of the EVGS is sufficient for observational gait assessment. The high correlation between the EVGS and the GMFM-66 supports its construct validity. The authors propose an MDC of 6.0 for the EVGS. These results can help in the application of EVGS to children with CP at GMFCS level I-II with mild to moderate gait pathology, as there were few children with CP at GMFCS level III.
引用
收藏
页码:119 / 123
页数:5
相关论文
共 50 条
  • [31] Inter-rater and Intra-rater Reliability of a Mobile App Method to Measure Lumbar Lordosis
    Gnanasigamani, Jency Thangasheela
    Ramalingam, Vinodhkumar
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [32] Inter-rater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion
    Reham M. Abd Elrahim
    Eman A. Embaby
    Mohamed F. Ali
    Ragia M. Kamel
    Bulletin of Faculty of Physical Therapy, 2016, 21 (2) : 80 - 87
  • [33] Inter-Rater and Intra-Rater Reliability of the Bahasa Melayu Version of Rose Angina Questionnaire
    Hassan, N. B.
    Choudhury, S. R.
    Naing, L.
    Conroy, R. M.
    Rahman, A. R. A.
    ASIA-PACIFIC JOURNAL OF PUBLIC HEALTH, 2007, 19 (03) : 45 - 51
  • [34] Intra-rater and inter-rater reliability of pressure pain threshold assessment in stroke patients
    Zhang, Yong-Hui
    Wang, Yu-Chen
    Hu, Gong-Wei
    Ding, Xiao-Qin
    Shen, Xiao-Hua
    Ng, Hui Ya
    Rong, Ji-Feng
    Wang, Xue-Qiang
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (04) : 549 - 557
  • [35] Intra-rater and inter-rater reliability of the rapid entire body assessment (REBA) tool
    Schwartz, Adam H.
    Albin, Thomas J.
    Gerberich, Susan G.
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2019, 71 : 111 - 116
  • [36] Inter-rater and intra-rater reliability of cerebral blood flow measures obtained using the Brain Acoustic Monitor
    Acocello, Shellie
    Broshek, Donna K.
    Saliba, Susan
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 221 : 85 - 91
  • [37] Intra-rater and inter-rater reliability of the standardized ultrasound protocol for assessing subacromial structures
    Hougs Kjaer, Birgitte
    Ellegaard, Karen
    Wieland, Ina
    Warming, Susan
    Juul-Kristensen, Birgit
    PHYSIOTHERAPY THEORY AND PRACTICE, 2017, 33 (05) : 398 - 409
  • [38] An evaluation of the inter-rater and intra-rater reliability of OccuPro's functional capacity evalution
    Scheel, Carrie
    Mecham, Jim
    Zuccarello, Vic
    Mattes, Ryan
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2018, 60 (03): : 465 - 473
  • [39] Intra-rater and inter-rater reliabilities of real-time acceleration gait analysis system
    Osaka, Hiroshi
    Shinkoda, Koichi
    Watanabe, Susumu
    Fujita, Daisuke
    Kobara, Kenichi
    Yoshimura, Yosuke
    Ito, Tomotaka
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2016, 11 (04) : 333 - 338
  • [40] Inter-rater and intra-rater agreement on the Nordic Orofacial Test-Screening examination in children, adolescents and young adults with cerebral palsy
    Edvinsson, Siv Elisabet
    Lundqvist, Lars-Olov
    ACTA ODONTOLOGICA SCANDINAVICA, 2014, 72 (02) : 120 - 129