Intra-rater and inter-rater reliability, minimal detectable change, and construct validity of the Edinburgh Visual Gait Score in children with cerebral palsy

被引:1
|
作者
Abe, Hirokazu [1 ,5 ]
Koyanagi, Shotaro [2 ]
Kusumoto, Yasuaki [3 ]
Himuro, Nobuaki [4 ]
机构
[1] Saitama Childrens Med Ctr, Dept Hlth Care & Child Dev, Saitama, Japan
[2] Visiting Nursing Stn Asuka, Dept Rehabil, Hiroshima, Japan
[3] Fukushima Med Univ Sch Hlth Sci, Dept Phys Therapy, Fukushima, Japan
[4] Sapporo Med Univ, Sch Med, Dept Publ Hlth, Sapporo, Japan
[5] Saitama Childrens Med Ctr, Dept Hlth Care & Child Dev, 1-2,Shintoshin,Chuo Ku, Saitama, Saitama 3308777, Japan
关键词
Cerebral palsy; Observational gait assessment; Gross Motor Function Measure; Minimal detectable change; BOTULINUM-TOXIN-A; GMFCS LEVELS I; MULTILEVEL SURGERY; MANAGEMENT; QUALITY; INDEX; KNEE;
D O I
10.1016/j.gaitpost.2022.03.004
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: The Edinburgh Visual Gait Score (EVGS) has been used for observational gait assessment in children with cerebral palsy (CP). However, the measurement error of the EVGS and its detailed relationship with gross motor function remain unclear. Research questions: This study aimed to confirm the intra-rater and inter-rater reliability as well as the minimal detectable change (MDC) values for the EVGS with the use of the video analysis software and examine the relationship between the EVGS and the Gross Motor Function Measure 66 (GMFM-66) with regard to construct validity. Methods: This cross-sectional study was conducted for 62 children (mean age 11.3 +/- 3.9 years) with spastic CP at Gross Motor Function Classification System (GMFCS) level I (32 children), II (25 children) or III (5 children). Three raters independently scored the EVGS using Kinovea video analysis software. The intra-rater and inter rater reliability were calculated using intra-class correlation coefficients (ICC2,1), and the MDC90 was calculated using standard error of measurement. The construct validity was examined by correlating the EVGS with the GMFM-66. Results: The EVGS showed good or excellent reliability within each rater (ICC2,1 = 0.90-0.97) and between raters (ICC2,1 = 0.91). The MDC90 of the EVGS ranged from 3.6 to 6.0. There was a significant correlation between the EVGS and the GMFM-66 (r = 0.69 to 0.73, p < 0.001). Significance: The intra-rater and inter-rater reliability of the EVGS is sufficient for observational gait assessment. The high correlation between the EVGS and the GMFM-66 supports its construct validity. The authors propose an MDC of 6.0 for the EVGS. These results can help in the application of EVGS to children with CP at GMFCS level I-II with mild to moderate gait pathology, as there were few children with CP at GMFCS level III.
引用
收藏
页码:119 / 123
页数:5
相关论文
共 50 条
  • [1] Intra-rater reliability, inter-rater reliability and minimal detectable change of the posterior shoulder endurance test in elite athletes
    Powell, Andrew
    Levy, Emma
    Heneghan, Nicola R.
    Horsley, Ian
    PHYSICAL THERAPY IN SPORT, 2021, 49 : 62 - 67
  • [2] Validity and intra- and inter-rater reliability of the Observational Gait Scale for children with spastic cerebral palsy
    Araujo, P. A.
    Kirkwood, R. N.
    Figueiredo, E. M.
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2009, 13 (03) : 267 - 273
  • [3] Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
    Mihalinec, Katja
    Martinez-Cepa, Carmen B.
    Zuil-Escobar, Juan C.
    Kejzar, Natasa
    Vauhnik, Renata
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [4] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas
    EURASIAN JOURNAL OF EDUCATIONAL RESEARCH, 2014, (57): : 113 - 135
  • [5] Optoelectronic plethysmography: Intra-rater and inter-rater reliability in healthy subjects
    Vieira, Danielle S. R.
    Hoffman, Mariana
    Pereira, Danielle A. G.
    Britto, Raquel R.
    Parreira, Veronica F.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2013, 189 (03) : 473 - 476
  • [6] INTER-RATER AND INTRA-RATER RELIABILITY OF UROFLOWMETRY INTERPRETATION IN ADULT WOMEN
    Rickey, Leslie M.
    Mueller, Elizabeth R.
    Newman, Diane K.
    Markland, Alayne D.
    Falke, Chloe
    Rudser, Kyle
    Lukacz, Emily S.
    JOURNAL OF UROLOGY, 2023, 209 : E519 - E519
  • [7] Inter-rater and intra-rater reliability of the airway diameter measured by sonography
    Gómez-Tamayo J.C.
    Puerta-Guarín J.I.
    Rojas-Camejo C.M.
    Caicedo J.P.
    Calvache J.A.
    Journal of Ultrasound, 2018, 21 (1) : 35 - 40
  • [8] INTER-RATER AND INTRA-RATER RELIABILITY OF BRIEF PSYCHIATRIC RATING SCALE
    FLEMENBAUM, A
    ZIMMERMANN, RL
    PSYCHOLOGICAL REPORTS, 1973, 32 (03) : 783 - 792
  • [9] The Scarbase Duo®: Intra-rater and inter-rater reliability and validity of a compact dual scar assessment tool
    Fell, Matthew
    Meirte, Jill
    Anthonissen, Mieke
    Maertens, Koen
    Pleat, Jonathon
    Moortgat, Peter
    BURNS, 2016, 42 (02) : 336 - 344
  • [10] Intra-rater and inter-rater reliability of 3D facial measurements
    Hobbs-Murphy, Kayna
    Olmedo-Nockideneh, Isabel
    Brazile, William J.
    Morris, Kristen
    Rosecrance, John
    APPLIED ERGONOMICS, 2024, 116