Intrapartum surveillance of IUGR fetuses with cardiotocography and fetal pulse oximetry

被引:1
|
作者
Siristatidis, C [1 ]
Salamalekis, E [1 ]
Vitoratos, N [1 ]
Loghis, C [1 ]
Salloum, J [1 ]
Kassanos, D [1 ]
Panayotopoulos, N [1 ]
Creatsas, G [1 ]
机构
[1] Univ Athens, Sch Med, Dept Obstet & Gynecol 2, Aretaieion Hosp, GR-11527 Athens, Greece
来源
BIOLOGY OF THE NEONATE | 2003年 / 83卷 / 03期
关键词
intrauterine growth retardation; fetal pulse oximetry; fetal hypoxia during labor;
D O I
10.1159/000068923
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective: To investigate the efficacy and safety of intrapartum fetal pulse oximetry, as a predictor of metabolic acidosis at birth of fetuses with intrauterine growth retardation (IUGR). Study Design: We studied 18 IUGR fetuses (group I) and a control group of 30 appropriate for gestational age (AGA) fetuses (group II) during labor. Both groups had abnormal fetal heart rate tracings and were monitored simultaneously throughout labor with cardiotocography and fetal pulse oximetry. Apgar scores, pH and base excess of fetal blood obtained from the umbilical artery after delivery were compared in both groups. Setting: The Fetal Surveillance Unit of the 2nd Department of Obstetrics and Gynecology, Aretaieion Hospital, Medical. School, Athens University. Results: In IUGR fetuses, when their oxygen saturation value (FSPO2) was less than 34%, cord artery pH was 7.10 +/- 0.04, base excess-13 +/- -1 mmol/l and Apgarscores less than or equal to 5 at the 5th min, and when FSPO2 was over 35%, artery pH was 7.29 +/- 0.08, base excess -8 +/- -2 mmol/l and Apgar scores greater than or equal to 7 at the 5th minute. In cases of drops of FSPO2 below 30% for more than 2 min, labor was completed operatively and cord pH was 7.00 +/- 0.04, base excess -15 +/- -2 mmol/l and Apgar scores less than or equal to 5 at the 5th minute. In AGA fetuses, when FSPO2 was over 30%, artery pH was over 7.20, base excess <-11 mmol/l and Apgar scores 2 9 at the 5th minute; in contrast, when FSPO2 was <30% for 2 min, a cesarean section was performed and cord pH was less than or equal to 7.02, base excess greater than or equal to -13 mmol/l and Apgarscores less than or equal to 4 at the 5th minute. Conclusions: In IUGR fetuses, FSPO2 values less than 34% represent an acidotic status, while values of greater than or equal to 35% are well tolerated. Fetal pulse oximetry proved reliable, according to umbilical cord blood measurements and Apgar scores, reducing cesarean deliveries in cases of nonreassuring cardiotocographic patterns in IUGR fetuses. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:162 / 165
页数:4
相关论文
共 50 条
  • [1] The efficacy of intrapartum fetal surveillance when fetal pulse oximetry is added to cardiotocography
    vandenBerg, PP
    Dildy, GA
    Luttkus, A
    Mason, GC
    Harvey, CJ
    Nijhuis, JG
    Jongsma, HW
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 : S67 - S71
  • [2] Intrapartum cardiotocography and fetal pulse oximetry in assessing fetal hypoxia
    Leszczynska-Gorzelak, B
    Poniedzialek-Czajkowska, E
    Oleszczuk, J
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2002, 76 (01) : 9 - 14
  • [3] Pulse oximetry as an additional method for intrapartum fetal surveillance
    Fuhr, N
    Hopp, H
    Runkel, S
    Weitzel, H
    [J]. LABOR AND DELIVERY, 1998, : 393 - 395
  • [4] Fetal pulse oximetry:: clinical evaluation during intrapartum surveillance
    Kühnert, M
    Seelbach-Göbel, B
    [J]. 2ND INTERNATIONAL CONGRESS ON NEW TECHNOLOGIES IN REPRODUCTIVE MEDICINE, NEONATOLOGY AND GYNECOLOGY, 1999, : 103 - 110
  • [5] The future of intrapartum fetal pulse oximetry
    Dildy, GA
    [J]. CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2001, 13 (02) : 133 - 136
  • [6] Update on intrapartum fetal pulse oximetry
    East, CE
    Colditz, PB
    Begg, LM
    Brennecke, SP
    [J]. AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2002, 42 (02): : 119 - 124
  • [7] The unresolved role of cardiotocography (CTG), fetal ECG (STAN) and intrapartum fetal pulse oximetry (IFPO) as diagnostic methods for fetal hypoxia
    Sholapurkar, S. L.
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2014, 34 (08) : 757 - 757
  • [8] Fetal pulse oximetry improves intrapartum fetal assessment
    Carrillo, J
    Insunza, A
    Latorre, R
    Mercado, M
    Cardenas, F
    Novoa, JM
    Paiva, E
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 189 (06) : S184 - S184
  • [9] INTRAPARTUM FETAL PULSE OXIMETRY - PRESENT AND FUTURE
    ELCHALAL, U
    WEISSMAN, A
    ABRAMOV, Y
    ABRAMOV, D
    WEINSTEIN, D
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1995, 50 (02) : 131 - 137
  • [10] Intrapartum fetal pulse oximetry and fetal heart rate decelerations
    Puertas, A
    Navarro, M
    Velasco, R
    Montoya, E
    Miranda, JA
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2004, 85 (01) : 12 - 17