Expression of uncertainty during measurement of X-ray diffraction residual stress

被引:0
|
作者
François, M
Ferreira, C
Guillén, R
机构
[1] Univ Technol Troyes, LASMIS, F-10010 Troyes, France
[2] Ctr Tech Belchamp, PSA Peugeot Citroen, F-25420 Voujeaucort, France
[3] Univ Nantes, GemLAMM, F-44602 St Nazaire, France
来源
JOURNAL DE PHYSIQUE IV | 2004年 / 118卷
关键词
D O I
10.1051/jp4:2004118012
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In the present work, a general method to calculate the uncertainty in X-ray stress analysis is proposed. It is in agreement with the current practice in metrology [1, 2, 3]. The uncertainty, expressed by a standard deviation is decomposed into several variance terms that can be calculated either from statistical experimental data or from physical modelling of the errors. The proposed model takes into account random errors due to the counting statistics and temperature fluctuations as well as systematic errors due to goniometer adjustment (beam and specimen alignment, W offset). A method to assess the uncertainty due to the X-ray elasticity constants is also presented. Each term is expressed by a simple formula that enables the operator to identify and quantify easily the influence of the acquisition parameters on the uncertainty and allow him to make choices in order to reduce it.
引用
收藏
页码:99 / 108
页数:10
相关论文
共 50 条
  • [41] Triaxial measurement of residual stress after high feed milling using x-ray diffraction
    Zauskova, Lucia
    Czan, Andrej
    Sajgalik, Michal
    Drbul, Mario
    Rysava, Zdenka
    12TH INTERNATIONAL SCIENTIFIC CONFERENCE OF YOUNG SCIENTISTS ON SUSTAINABLE, MODERN AND SAFE TRANSPORT, 2017, 192 : 982 - 987
  • [42] Study of residual stress measurement of rolling aluminum alloy using x-Ray diffraction method
    Sun, Jiantong
    Li, Xiaoyan
    Zhang, Liang
    Yao, Wentao
    Li, Qingqing
    Hanjie Xuebao/Transactions of the China Welding Institution, 2017, 38 (01): : 61 - 64
  • [43] Measurement of residual stress in arc welded lap joints by cosα X-ray diffraction method
    Lin, Jian
    Ma, Ninshu
    Lei, Yongping
    Murakawa, Hidekazu
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2017, 243 : 387 - 394
  • [44] Residual stress measurement of new and in-service X70 pipelines by X-ray diffraction method
    Gou, Ruibin
    Zhang, Yiliang
    Xu, Xuedong
    Sun, Liang
    Yang, Yong
    NDT & E INTERNATIONAL, 2011, 44 (05) : 387 - 393
  • [45] X-ray diffraction in thermal treatments: Determination of residual austenite by X-ray diffraction
    Bach, M
    Broll, N
    Cornet, A
    Gaide, L
    JOURNAL DE PHYSIQUE IV, 1996, 6 (C4): : 887 - 895
  • [46] Measurement of residual stresses in CFRP laminates by X-ray diffraction method
    Balasingh, C
    Singh, V
    BULLETIN OF MATERIALS SCIENCE, 1997, 20 (03) : 325 - 332
  • [47] Measurement of residual stresses in CFRP laminates by X-ray diffraction method
    C Balasingh
    Vandana Singh
    Bulletin of Materials Science, 1997, 20 : 325 - 332
  • [48] Averaging during x-ray stress measurement
    Moller, H
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1943, 87 : 229 - 229
  • [49] Study by X-ray diffraction and mechanical analysis of the residual stress generation during thermal spraying
    Pina, J
    Dias, A
    Lebrun, JL
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2003, 347 (1-2): : 21 - 31
  • [50] X-ray Diffraction for the Determination of Residual Stress of Crystalline Material: An Overview
    Lodh, Arijit
    Thool, Khushahal
    Samajdar, Indradev
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2022, 75 (04) : 983 - 995