Improved performances of electrodes based on Cu2+-loaded copper hexacyanoferrate for hydrogen peroxide detection

被引:35
|
作者
Guadagnini, Lorella [1 ]
Tonelli, Domenica [1 ]
Giorgetti, Marco [1 ]
机构
[1] Univ Bologna, Dept Phys & Inorgan Chem, INSTM, UdR Bologna, I-40136 Bologna, Italy
关键词
Hydrogen peroxide; Copper hexacyanoferrate; Copper intercalation; Chronoamperometry; GC electrode; PHOTOINDUCED MAGNETIZATION; SOLID-STATE; IRON; NANOPARTICLES; STABILITY; IDENTITY; SENSOR; FILMS;
D O I
10.1016/j.electacta.2010.04.019
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Copper hexacyanoferrate thin films were potentiodynamically deposited on glassy carbon electrodes and employed for the chronoamperometric detection of hydrogen peroxide at 0.0 V vs. SCE. A new experimental procedure based on the intercalation of copper ions inside the structure of the films led to sensors with improved performances. The modified electrode displayed an increased sensitivity to hydrogen peroxide detection together with a wider linear response range and a lower detection limit. Furthermore, even if the electrode response decreased with use, the initial activity could be restored by performing a new intercalation procedure. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5036 / 5039
页数:4
相关论文
共 50 条
  • [1] Structural study of the Cu2+-loaded copper hexacyanoferrate electrode deposited on indium tin oxide substrate
    Giorgetti, M.
    Aquilanti, G.
    Minicucci, M.
    [J]. 15TH INTERNATIONAL CONFERENCE ON X-RAY ABSORPTION FINE STRUCTURE (XAFS15), 2013, 430
  • [2] Copper hexacyanoferrate modified electrodes for hydrogen peroxide detection as studied by X-ray absorption spectroscopy
    Marco Giorgetti
    Domenica Tonelli
    Mario Berrettoni
    Giuliana Aquilanti
    Marco Minicucci
    [J]. Journal of Solid State Electrochemistry, 2014, 18 : 965 - 973
  • [3] Copper hexacyanoferrate modified electrodes for hydrogen peroxide detection as studied by X-ray absorption spectroscopy
    Giorgetti, Marco
    Tonelli, Domenica
    Berrettoni, Mario
    Aquilanti, Giuliana
    Minicucci, Marco
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2014, 18 (04) : 965 - 973
  • [4] Copper Nanoparticles with Copper Hexacyanoferrate and Poly(3,4-ethylenedioxythiophene) Hybrid Film Modified Electrode for Hydrogen Peroxide Detection
    Tsai, Tsung-Hsuan
    Chen, Tse-Wei
    Chen, Shen-Ming
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (10): : 4628 - 4637
  • [5] The effect of hydrogen peroxide in a citric acid based copper slurry on Cu polishing
    Eom, Dae-Hong
    Kim, In-Kwon
    Han, Ja-Hyung
    Park, Jin-Goo
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2007, 154 (01) : D38 - D44
  • [6] Amperometric sensor for hydrogen peroxide, based on Cu2O or CuO modified carbon paste electrodes
    Garjonyte, R
    Malinauskas, A
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (01): : 122 - 123
  • [7] Amperometric sensor for hydrogen peroxide, based on Cu2O or CuO modified carbon paste electrodes
    Rasa Garjonyte
    A. Malinauskas
    [J]. Fresenius' Journal of Analytical Chemistry, 1998, 360 : 122 - 123
  • [8] Non-enzymatic electrochemical sensors for the detection of hydrogen peroxide based on Cu2O/Cu nanocomposites
    Luo, Binbin
    Li, Xueming
    Yang, Jianchun
    Li, Xianli
    Xue, Longping
    Li, Xiaolin
    Gu, Jiakun
    Wang, Mengzhen
    Jiang, Lu
    [J]. ANALYTICAL METHODS, 2014, 6 (04) : 1114 - 1120
  • [9] Amperometric Detection of Hydrogen Peroxide Using Glassy Carbon Electrodes Modified with Chromium Hexacyanoferrate/Single-Walled Carbon Nanotube Nanocomposites
    Zhang, Wei
    Wang, Guangfeng
    Zhang, Xiaojun
    Fang, Bin
    [J]. ELECTROANALYSIS, 2009, 21 (02) : 179 - 183
  • [10] Hydrogel-Based Electrodeposition of Copper Nanoparticles for Selective Detection for Hydrogen Peroxide
    Han, Jihun
    Kim, Jihyeon
    Kim, Byung-Kwon
    Park, Kyungsoon
    [J]. CHEMOSENSORS, 2023, 11 (07)