Diagnostic Performance of PET Versus SPECT Myocardial Perfusion Imaging in Patients with Smaller Left Ventricles: A Substudy of the 18F-Flurpiridaz Phase III Clinical Trial

被引:16
|
作者
Packard, Rene R. Sevag [1 ,2 ,3 ]
Lazewatsky, Joel L. [4 ]
Orlandi, Cesare [4 ]
Maddahi, Jamshid [1 ,5 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Med, Div Cardiol, Los Angeles, CA 90095 USA
[2] Ronald Reagan UCLA Med Ctr, Los Angeles, CA 90095 USA
[3] Vet Affairs West LA Med Ctr, Los Angeles, CA 90073 USA
[4] Lantheus Med Imaging, North Billerica, MA USA
[5] Univ Calif Los Angeles, David Geffen Sch Med, Dept Mol & Med Pharmacol, Nucl Med Clin, Los Angeles, CA 90095 USA
关键词
diagnostic performance; left ventricle size; SPECT MPI; PET MPI; flurpiridaz; CORONARY-ARTERY-DISEASE; CARDIOVASCULAR MAGNETIC-RESONANCE; POSITRON-EMISSION-TOMOGRAPHY; COMPUTED-TOMOGRAPHY; EJECTION FRACTION; RISK-ASSESSMENT; BLOOD-FLOW; RB-82; PET; ACCURACY; ANGIOGRAPHY;
D O I
10.2967/jnumed.120.252007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The performance of SPECT myocardial perfusion imaging (MPI) may deteriorate in smaller hearts, primarily because of the lower resolution of conventional Anger cameras. F-18-flurpiridaz is a novel PET MPI agent with superior image and defect resolution. We sought to determine the diagnostic performance of Tc-99m-labeled SPECT MPI compared with F-18-flurpiridaz PET MPI according to left ventricle (LV) size. Methods: We conducted a substudy of the phase III clinical trial of flurpiridaz (n = 750) and stratified diagnostic performance according to the median PET LV end-diastolic volume (LVEDV), with smaller LVs defined as having an LVEDV of less than 113 mL (n = 369) and larger LVs defined as having an LVEDV of at least 113 mL (n = 381). Images were interpreted by the majority rule of 3 independent masked readers. The reference standard was quantitative invasive angiography, with at least 50% stenosis in at least 1 coronary artery considered significant. Results: SPECT performance decreased significantly from an area under the curve (AUC) of 0.75 in larger LVs to 0.67 in smaller LVs (P = 0.03), whereas PET performance was similar in larger and smaller LVs (AUC, 0.79 vs. 0.77, P = 0.49). Accordingly, in smaller LVs, PET had a higher AUC (0.77) than the SPECT AUC (0.67) (P < 0.0001), a phenomenon driven by female patients (P < 0.0001). In smaller LVs, there was a degradation of SPECT sensitivity that was highly significant (P < 0.001), whereas there was no significant change in PET sensitivity according to LV size (P = 0.07). Overall, PET had significantly higher sensitivity than SPECT in both smaller LVs (67% vs. 43%, P < 0.001) and larger LVs (76% vs. 61%, P < 0.001). The specificities of PET and SPECT were similar in larger LVs (76% vs. 83%, P = 0.11). Although SPECT specificity improved in smaller compared with larger LVs (90% vs. 83%, P = 0.03), the PET specificity did not change with LV size (76% vs. 76%, P = 0.9). Conclusion: The diagnostic performance of F-18-flurpiridaz PET MPI is not affected by LV size and is superior to SPECT MPI in patients with smaller LVs, highlighting the importance of appropriate test selection in these patients.
引用
收藏
页码:849 / 854
页数:6
相关论文
共 50 条
  • [21] Improved Assessment of Coronary Artery Disease in Obese Subjects with Flurpiridaz F18 PET Myocardial Perfusion Imaging: A Subgroup Analysis of the Flurpiridaz F-18 303 Phase 3 Study
    Patel, Krishna
    maddahi, Jamshid
    Agostini, Denis
    Bax, Jeroen
    Beanlands, Rob
    Berman, Daniel
    Dorbala, Sharmila
    Garcia, Ernest
    Feldman, James
    Heller, Gary
    Knuuti, Juhani
    Martinez-Clark, Pedro
    Pelletier-Galarneau, Matthieu
    Shepple, Benjamin
    Tamaki, Nagara
    Udelson, James
    Bateman, Timothy
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [22] The Second Phase-3 Multi-Center Trial of Flurpiridaz F-18 PET Myocardial Perfusion Imaging for Coronary Artery Disease Evaluation
    Maddahi, Jamshid
    Agostini, Denis
    Bateman, Timothy
    Bax, Jeroen
    Beanlands, Rob
    Berman, Daniel
    Dorbala, Sharmila
    Garcia, Ernest
    Feldman, James
    Heller, Gary
    Knuuti, Juhani
    Martinez-Clark, Pedro
    Pelletier-Galarneau, Matthieu
    Shepple, Benjamin
    Tamaki, Nagara
    Tranquart, Francois
    Udelson, James
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [23] Diagnostic performance of automated myocardial blood flow quantitation by flurpiridaz F18 positron emission tomography: a sub-study of the flurpiridaz F18 301 clinical trial
    Packard, Rene
    Votaw, John
    Cooke, Charles
    Van Train, Kenneth
    Garcia, Ernest
    Maddahi, Jamshid
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [24] Low dose dobutamin gated SPECT myocardial perfusion imaging versus F-18 fluorodeoxyglucose PET in the assessment of myocardial viability
    Lindner, O
    Kammeier, A
    Rosanwo, D
    Wielepp, P
    Burchert, W
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 964 - 964
  • [25] Preliminary and Comparative Experiment Study Between 18F-Flurpiridaz and 13N-NH3•H2O Myocardial Perfusion Imaging With PET/CT in Miniature Pigs
    Wang, Jiao
    Li, Shuai
    Liu, Tian-wen
    Zhang, Jie-min
    Chen, Yue
    Li, Jian-ming
    Xu, Wen-gui
    MOLECULAR IMAGING, 2020, 19
  • [26] Diagnostic accuracy of SPECT and PET myocardial perfusion imaging in patients with left bundle branch block or ventricular-paced rhythm
    Mahesh K. Vidula
    Philip Wiener
    Senthil Selvaraj
    Muhammad Shoaib Khan
    Usman Abdul Salam
    Chaitanya Rojulpote
    Scott D. Metzler
    Srinivas Denduluri
    Marie Guerraty
    Howard Julien
    Paco E. Bravo
    Journal of Nuclear Cardiology, 2021, 28 : 981 - 988
  • [27] Diagnostic accuracy of SPECT and PET myocardial perfusion imaging in patients with left bundle branch block or ventricular-paced rhythm
    Vidula, Mahesh K.
    Wiener, Philip
    Selvaraj, Senthil
    Khan, Muhammad Shoaib
    Salam, Usman Abdul
    Rojulpote, Chaitanya
    Metzler, Scott D.
    Denduluri, Srinivas
    Guerraty, Marie
    Julien, Howard
    Bravo, Paco E.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (03) : 981 - 988
  • [28] Clinical Trial Report: Prevalence and Predictors of Mechanical Dyssynchrony as Defined by Phase Analysis in Patients with Left Ventricular Dysfunction Undergoing Gated SPECT Myocardial Perfusion Imaging
    Ou, Jiafu
    Gropler, Robert J.
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2011, 4 (03) : 175 - 176
  • [29] Clinical outcome of patients with previous myocardial infarction and left ventricular dysfunction assessed with myocardial 99mTc-MIBI SPECT and 18F-FDG PET
    Zhang, XL
    Liu, XJ
    Wu, QY
    Shi, RF
    Gao, RL
    Liu, YZ
    Hu, SS
    Tian, YQ
    Guo, SX
    Fang, W
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (08) : 1166 - 1173
  • [30] 18F-FDG PET Imaging of Myocardial Viability in an Experienced Center with Access to 18F-FDG and Integration with Clinical Management Teams: The Ottawa-FIVE Substudy of the PARR 2 Trial
    Abraham, Arun
    Nichol, Graham
    Williams, Kathryn A.
    Guo, Ann
    deKemp, Robert A.
    Garrard, Linda
    Davies, Ross A.
    Duchesne, Lloyd
    Haddad, Haissam
    Chow, Benjamin
    DaSilva, Jean
    Beanlands, Rob S. B.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (04) : 567 - 574