Multi-scale mechanical investigation of stainless steel and cobalt-chromium stents

被引:30
|
作者
Kapnisis, Konstantinos [1 ]
Constantinides, Georgios [1 ]
Georgiou, Harry [1 ]
Cristea, Daniel [2 ]
Gabor, Camelia [2 ]
Munteanu, Daniel [2 ]
Brott, Brigitta [3 ]
Anderson, Peter [4 ]
Lemons, Jack [5 ]
Anayiotos, Andreas [1 ]
机构
[1] Cyprus Univ Technol, Dept Mech Engn & Mat Sci & Engn, CY-3036 Limassol, Cyprus
[2] Transilvania Univ Brasov, Dept Mat Sci, Brasov 500036, Romania
[3] Univ Alabama Birmingham, Dept Med, Birmingham, AL 35294 USA
[4] Univ Alabama Birmingham, Dept Pathol, Birmingham, AL 35294 USA
[5] Univ Alabama Birmingham, Dept Prosthodont, Birmingham, AL 35294 USA
关键词
Stents; In-stent restenosis (ISR); Fracture; Nanoindentation; Mechanical properties; CORONARY-ARTERY; BARE-METAL; STRUT THICKNESS; FRACTURE; RESTENOSIS; FATIGUE; INDENTATION; NANOINDENTATION; IMPLANTATION; EXPERIENCE;
D O I
10.1016/j.jmbbm.2014.09.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In-stent restenosis (ISR) remains a significant limitation despite the considerable previous clinical and investigative emphasis on the problem. Complications arising from the interaction of stent materials with the surrounding vessel wall as well as from the mechanical forces developing after implantation, play an important role in the development of ISR. To investigate the relation between mechanical factors and stent structural integrity, and to identify any structural weakness points on the geometry of commercially available Stainless Steel and Cobalt Chromium stents, accelerated pulsatile durability tests were carried out in a simulated physiological environment. Potential spatial variations in the mechanical properties on stent struts and their role in the observed premature failures of the stent devices during operation were also examined. Fretting wear and fatigue-induced fractures were found on stent surfaces after exposure to cyclic loading similar to that arising in vivo. Nanoindentation studies performed on various locations along the stent struts have shown that the hardness of specific stent locations significantly increases after mechanical expansion. The increase in hardness was associated with a reduction of the material's ability to dissipate energy in plastic deformations, therefore an increased vulnerability to fracture and fatigue. We conclude that the locations of fatigue fractures in stent struts are controlled not only by the geometrically-driven stress concentrations developing during cyclic loading but also by the local material mechanical changes that are imparted on various parts of the stent during the deployment process. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:240 / 251
页数:12
相关论文
共 50 条
  • [1] Comparison of thin-strut cobalt-chromium stents and stainless steel stents in a porcine model of neointimal hyperplasia
    Milewski, Krzysztof
    Zurakowski, Aleksander
    Pajak, Jacek
    Zielinska-Pajak, Ewa
    Liszka, Lukasz
    Buszman, Piotr P.
    Bis, Jaroslaw
    Debinski, Marcin
    Buszman, Pawel
    [J]. MEDICAL SCIENCE MONITOR, 2010, 16 (01): : BR40 - BR44
  • [2] Very Late Pathological Responses to Cobalt-Chromium Everolimus-Eluting, Stainless Steel Sirolimus-Eluting, and Cobalt-Chromium Bare Metal Stents in Humans
    Mori, Hiroyoshi
    Atmakuri, Dheeraj R.
    Torii, Sho
    Braumann, Ryan
    Smith, Samantha
    Jinnouchi, Hiroyuki
    Gupta, Anuj
    Harari, Emanuel
    Shkullaku, Melsi
    Kutys, Robert
    Fowler, David
    Romero, Maria
    Virmani, Renu
    Finn, Aloke V.
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (11):
  • [3] RELEASE OF HEXAVALENT CHROMIUM FROM CORROSION OF STAINLESS-STEEL AND COBALT-CHROMIUM ALLOYS
    MERRITT, K
    BROWN, SA
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (05): : 627 - 633
  • [4] Implantation of new cobalt-chromium stents in the treatment of aortic coarctation
    Bialkowski, J.
    Szkutnik, M.
    Fiszer, R.
    [J]. EUROPEAN HEART JOURNAL, 2013, 34 : 395 - 396
  • [5] Acute stent recoil is increased in cobalt chromium compared to stainless steel stents
    Mylotte, D.
    Hovasse, T.
    Garot, P.
    Chevalier, B.
    Salvatella, N.
    Morice, M. C.
    Lefevre, T.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 409 - 409
  • [6] Environmentally sustainable electroplating of selective cobalt-chromium coating on stainless steel for efficient solar collectors
    Zall, Erik
    Nordenstrom, Andreas
    Jarn, Mikael
    Mossegard, Jonatan
    Wagberg, Thomas
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2022, 245
  • [7] Surface alteration of Cobalt-Chromium and duplex stainless steel alloys for biomedical applications: a concise review
    Mahajan, Amit
    Devgan, Sandeep
    Kalyanasundaram, Dinesh
    [J]. MATERIALS AND MANUFACTURING PROCESSES, 2023, 38 (03) : 260 - 270
  • [8] Fatigue and life prediction for cobalt-chromium stents: A fracture mechanics analysis
    Marrey, RV
    Burgermeister, R
    Grishaber, RB
    Ritchie, RO
    [J]. BIOMATERIALS, 2006, 27 (09) : 1988 - 2000
  • [9] Cobalt-chromium stents in porcine coronary arteries: angiographic and ultrasonographic outcomes
    Buszman, P.
    Zurakowski, A.
    Milewski, K.
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 : 417 - 417
  • [10] Fretting and anodic current of the taper interface of stainless steel hip stems/cobalt-chromium femoral heads
    Zhu, MK
    Windler, M
    [J]. STAINLESS STEELS FOR MEDICAL AND SURGICAL APPLICATIONS, 2003, 1438 : 235 - 246