Improving the dimensional accuracy of 3D x-ray microscopy data

被引:10
|
作者
Villarraga-Gomez, Herminso [1 ]
Kotwal, Naomi [2 ]
Parwani, Rachna [2 ]
Weiss, Daniel [3 ]
Krenkel, Martin [3 ]
Kimmig, Wolfgang [3 ]
Vom Hagen, Christoph Graf [2 ]
机构
[1] Carl Zeiss Ind Metrol LLC, Wixom, MI 48393 USA
[2] Carl Zeiss Xray Microscopy Inc, Dublin, CA USA
[3] Carl Zeiss Ind Messtech GmbH, Oberkochen, Germany
关键词
x-ray microscopy; 3D x-ray microscopes; computed tomography; dimensional metrology; dimensional accuracy; geometric magnification; optical magnification; COMPUTED-TOMOGRAPHY; CT; RESOLUTION;
D O I
10.1088/1361-6501/ac5a30
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
X-ray microscopy instruments have the unique ability to achieve nondestructive imaging with higher spatial resolutions than traditional x-ray computed tomography (CT) systems. This unique ability is of interest to industrial quality control entities, as they deal with small features in precision manufactured parts (with tolerances in the order of +/- 25 mu m or better). Since many of today's technology and manufacturing companies demand increasingly higher levels of precision, accuracy, and reliability for dimensional measurements on feature sizes that are much smaller than 5 mm, it would be ideal to further expand the imaging capabilities of x-ray microscopy to the field of precision metrology. To address such demand, this paper describes the development of a measurement workflow, through a package consisting of hardware and software, to improve the accuracy of dimensional data obtained with 3D x-ray microscopes (XRMs)-also known as sub-micrometer CT systems. The measurement workflow, called Metrology Extension (MTX), was designed to adjust and configure the XRM instrument work-zone to perform dimensional measurement tasks. The main adjustments of an XRM instrument through the MTX workflow, which must be implemented before scanning parts of interest for dimensional evaluation, include applying a distortion map correction on the image projections produced by the x-ray detector and a voxel scale correction. The main purpose of this article is to present, evaluate, and analyze the experimental results of various measurement tests to verify the metrological performance of several XRM systems operating with the MTX workflow. The main results show that these systems can produce repeatable and reproducible measurements, with repeatability standard deviations of the order of 0.1 mu m and reproducibility standard deviations of less than 0.5 mu m. In addition, coordinate-based 3D XRM measurements produce dimensional accuracies comparable to those offered by high-precision tactile coordinate measurement machines (with deviations within the range of +/- 0.95 mu m). Therefore, once the MTX workflow is executed, XRM instruments can be used to measure small volumes, in the order of (5 mm)(3) or less, with improved dimensional accuracy.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Extending the measurement capabilities of 3D X-ray microscopy to dimensional metrology
    Villarraga-Gómez, Herminso
    Kotwal, Naomi
    Zarnetta, Robert
    [J]. International Journal of Metrology and Quality Engineering, 2024, 15
  • [2] High resolution 3D x-ray diffraction microscopy
    Miao, JW
    Ishikawa, T
    Johnson, B
    Anderson, EH
    Lai, B
    Hodgson, KO
    [J]. PHYSICAL REVIEW LETTERS, 2002, 89 (08) : 088303/1 - 088303/4
  • [3] SUBMICRON RESOLUTION 3D X-RAY STRUCTURAL MICROSCOPY
    Larson, B. C.
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C33 - C33
  • [4] 3D Scanning Coherent X-ray Microscopy at PtyNAMi
    Schropp, Andreas
    Achilles, Silvio
    Patjens, Svenja
    Seiboth, Frank
    Stuckelberger, Michael E.
    Jiang, Zhimin
    Pikul, James H.
    Schroer, Christian G.
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [5] Metrology of 3D IC with X-ray Microscopy and Nano-scale X-ray CT
    Wang, Steve
    Gelb, Jeff
    Lau, S. H.
    Yun, Wenbing
    [J]. PROCEEDINGS OF THE 2009 IEEE INTERNATIONAL INTERCONNECT TECHNOLOGY CONFERENCE, 2009, : 131 - 133
  • [6] 3D X-ray microscopy with a CsPbBr3 nanowire scintillator
    Dierks, Hanna
    Zhang, Zhaojun
    Lamers, Nils
    Wallentin, Jesper
    [J]. NANO RESEARCH, 2023, 16 (01) : 1084 - 1089
  • [7] 3D X-ray microscopy with a CsPbBr3 nanowire scintillator
    Hanna Dierks
    Zhaojun Zhang
    Nils Lamers
    Jesper Wallentin
    [J]. Nano Research, 2023, 16 : 1084 - 1089
  • [8] 3D X-ray ultra-microscopy of bone tissue
    Langer, M.
    Peyrin, F.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2016, 27 (02) : 441 - 455
  • [9] 3D X-ray ultra-microscopy of bone tissue
    M. Langer
    F. Peyrin
    [J]. Osteoporosis International, 2016, 27 : 441 - 455
  • [10] Study of Electromigration of Solder Microbumps by 3D X-ray Microscopy
    Lin, Tzu-Wen
    Shie, Kai-Cheng
    Chen, Chih
    Tu, King-Ning
    [J]. 2020 15TH INTERNATIONAL MICROSYSTEMS, PACKAGING, ASSEMBLY AND CIRCUITS TECHNOLOGY CONFERENCE (IMPACT 2020), 2020, : 76 - 78