Flow Cytometry Immunophenotyping (FCI) of Fine Needle Aspirates (FNAs) of Lymph Nodes

被引:1
|
作者
Paro, Mirjana Mariana Kardum [1 ]
Siftar, Zoran [1 ]
Kardum-Skelin, Ika [2 ,3 ]
Sustercic, Dunja [2 ]
Nazor, Aida [1 ]
Flegar-Mestric, Zlata [1 ,4 ]
Jaksic, Branimir [3 ]
机构
[1] Merkur Univ Hosp, Inst Clin Chem, Zagreb, Croatia
[2] Merkur Univ Hosp, Lab Cytol & Hematol, Dept Med, Zagreb, Croatia
[3] Univ Zagreb, Sch Med, Zagreb 41001, Croatia
[4] Univ Zagreb, Fac Pharm & Biochem, Zagreb 41000, Croatia
关键词
flow cytometry immunophenotyping (FCI); fine needle aspirates (FNAs); CANADIAN CONSENSUS RECOMMENDATIONS; NON-HODGKINS-LYMPHOMAS; HEMATOLOGIC NEOPLASIA; CYTOLOGIC SPECIMENS; DIAGNOSIS; LIGHT; LIMITATIONS; DISEASES; BLOOD;
D O I
暂无
中图分类号
Q98 [人类学];
学科分类号
030303 ;
摘要
Flow cytometry immunophenotyping (FCI) has an important role in the clinic work-up of fine needle aspirates (FNAs) of lymph nodes. Its standardization has been defined by proposed analytical protocols and procedures used to assure proper analytical results also in those non-routine samples. In Institute of Clinical Chemistry, "Merkur" University Hospital, FCI is accredited method according to laboratory accreditation standard ISO 15189. According to this laboratory accreditation standard, participation in external quality assessment (EQA) programs is a prerequisite for assuring integrity and quality of the entire laboratory process. A critical analysis of our institutional experience in the feasibility of FCI of the material obtained by FNA of lymph nodes with suspected lymphoma represented the purpose of the study. During an eight-year period in Institute of Clinical Chemistry, "Merkur" University Hospital, a total of 1295 FNA analysis was done, 245 of them with a possible diagnosis of B-cell Non-Hodgkin lymphomas (B-NHL) formed the basis of the study. Lymphocytes were isolated on density gradient according to Boyum et al. The average feasibility of FNAs for FCI analysis was 86 % (ranged 78-93%). An acceptable total cell number in FNAs for FCI analysis (4257) was established. In total population of respondents statistical significances in expressions of cellular antigens CD3, CD5, CD22, CD23, CD19 and CD5 on B-cells (CD5 + CD19 +) between patient's with final diagnosis of benign, reactive lymphoid proliferations and patient 's with diagnosis of B-NHL were found. EQA results analysis showed that all results were either inside target values ((X) over bar+/-1SD) or inside accepted values ((X) over bar+/-2SD). Compatibility of the restriction of imunoglobulins light chains determinated by FCI and cytomorphology diagnosis depends on the choice of criterion values of the light chains ratio which determine the monoclonality. According to the matrix of shares of all classified data of retained neural network, ranges of diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and prevalency of 82%, 72%, 93%, 48%, and 72% were produced. As a conclusion, FCI is a reliable methodology for phenotyping FNAs of lymph nodes with suspected B-NHLs detecting their clonality easily.
引用
收藏
页码:359 / 365
页数:7
相关论文
共 50 条
  • [31] Fine needle aspiration of lymph nodes
    André, N
    POINT VETERINAIRE, 2003, 34 (237): : 54 - 55
  • [32] Fine needle aspiration of lymph nodes
    Buley, ID
    JOURNAL OF CLINICAL PATHOLOGY, 1998, 51 (12) : 881 - 885
  • [33] CD123 IS USEFUL FOR IMMUNOPHENOTYPING CLASSICAL HODGKIN LYMPHOMA IN LYMPH NODES BY FLOW CYTOMETRY
    Fromm, Jonathan R.
    Thomas, Anju
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2009, 76B (06) : 400 - 400
  • [34] Lymph Node Fine-Needle Cytology: Beyond Flow Cytometry
    Peluso, Anna Lucia
    Ieni, Antonio
    Mignogna, Chiara
    Zeppa, Pio
    ACTA CYTOLOGICA, 2016, 60 (04) : 372 - 384
  • [35] A SIX-COLOR FLOW CYTOMETRY TUBE FOR IMMUNOPHENOTYPING CLASSICAL HODGKIN LYMPHOMA IN LYMPH NODES
    Fromm, Jonathan R.
    Wood, Brent L.
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2010, 78B (06) : 395 - 395
  • [36] A Six-Color Flow Cytometry Assay for Immunophenotyping Classical Hodgkin Lymphoma in Lymph Nodes
    Fromm, Jonathan R.
    Wood, Brent L.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2014, 141 (03) : 388 - 396
  • [37] Large cell transformation of mycosis fungoides in lymph nodes: A clinicopathologic study by flow cytometry and fine needle aspiration biopsy
    Wen, Hannah
    Cangiarella, Joan
    Kamino, Hideko
    Hymes, Kenneth
    Sen, Filiz
    MODERN PATHOLOGY, 2006, 19 : 119 - 120
  • [38] Role of fine-needle aspirate immunophenotyping by flow cytometry in rapid diagnosis of lymphoproliferative disorders
    Gupta, Ritu
    Naseem, Shano
    Kashyap, Rajesh
    Paul, Lily
    DIAGNOSTIC CYTOPATHOLOGY, 2007, 35 (07) : 381 - 385
  • [39] Fine-needle aspiration biopsy and flow cytometry immunophenotyping of lymphoid and myeloproliferative disorders of the spleen
    Zeppa, P
    Picardi, M
    Marino, G
    Troncone, G
    Fulciniti, F
    Vetrani, A
    Rotoli, B
    Palombini, L
    CANCER CYTOPATHOLOGY, 2003, 99 (02) : 118 - 127
  • [40] Polymerase chain reaction vs. conventional diagnosis in fine needle aspirates of tuberculous lymph nodes
    Goel, MM
    Ranjan, V
    Dhole, TN
    Srivastava, AN
    Mehrotra, A
    Kushwaha, MRS
    Jain, A
    ACTA CYTOLOGICA, 2001, 45 (03) : 333 - 340