Accuracy of ultrasound-guided intra-articular injections in guinea pig knees

被引:6
|
作者
Vazquez-Portalatin, N. [1 ]
Breur, G. J. [2 ]
Panitch, A. [1 ]
Goergen, C. J. [1 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Vet Clin Sci, W Lafayette, IN 47907 USA
来源
BONE & JOINT RESEARCH | 2015年 / 4卷 / 01期
关键词
osteoarthritis; cartilage; guinea pig; ultrasound; intra-articular; injection; OSTEOARTHRITIS;
D O I
10.1302/2046-3758.41.2000370
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Objective Dunkin Hartley guinea pigs, a commonly used animal model of osteoarthritis, were used to determine if high frequency ultrasound can ensure intra-articular injections are accurately positioned in the knee joint. Methods A high-resolution small animal ultrasound system with a 40 MHz transducer was used for image-guided injections. A total of 36 guinea pigs were anaesthetised with isoflurane and placed on a heated stage. Sterile needles were inserted directly into the knee joint medially, while the transducer was placed on the lateral surface, allowing the femur, tibia and fat pad to be visualised in the images. B-mode cine loops were acquired during 100 mu l. We assessed our ability to visualise 1) important anatomical landmarks, 2) the needle and 3) anatomical changes due to the injection. Results From the ultrasound images, we were able to visualise clearly the movement of anatomical landmarks in 75% of the injections. The majority of these showed separation of the fat pad (67.1%), suggesting the injections were correctly delivered in the joint space. We also observed dorsal joint expansion (23%) and patellar tendon movement (10%) in a smaller subset of injections. Conclusion The results demonstrate that this image-guided technique can be used to visualise the location of an intra-articular injection in the joints of guinea pigs. Future studies using an ultrasound-guided approach could help improve the injection accuracy in a variety of anatomical locations and animal models, in the hope of developing anti-arthritic therapies.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [41] Impact of an educational intervention utilising a three-dimensional-printed model for ultrasound-guided intra-articular injections of the dislocated shoulder
    Cosgrave, Conor
    Anakin, Megan
    Blyth, Phil
    Baillie, Louisa
    Beck, Sierra
    [J]. EMERGENCY MEDICINE AUSTRALASIA, 2024,
  • [42] Ultrasound-guided lumbar medial branch blocks and intra-articular facet joint injections: a systematic review and meta-analysis
    Ashmore, Zachary M.
    Bies, Michael M.
    Meiling, James B.
    Moman, Rajat N.
    Hassett, Leslie C.
    Hunt, Christine L.
    Cohen, Steven P.
    Hooten, W. Michael
    [J]. PAIN REPORTS, 2022, 7 (03) : E1008
  • [43] Sonographic criteria for therapy follow-up in the course of ultrasound-guided intra-articular injections of hyaluronic acid in hand osteoarthritis
    Klauser, Andrea S.
    Faschingbauer, Ralph
    Kupferthaler, Karin
    Feuchnter, Gudrun
    Wick, Marius C.
    Jaschke, Werner R.
    Mur, Erich
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : 1607 - 1611
  • [44] Clinical Effectiveness of Ultrasound-guided Intra-articular Corticosteroid and Local Anaesthetic Injections for Hip Osteoarthritis: A Randomised Controlled Trial (HIT)
    Paskins, Zoe
    Bromley, Kieran
    Lewis, Martyn
    Hughes, Gemma
    Hughes, Emily
    Cherrington, Andrea
    Hall, Alison
    Holden, Melanie
    Oppong, Raymond
    Stevenson, Kay
    Menon, Ajit
    Roberts, Philip
    Peat, George
    Jinks, Clare
    Foster, Nadine
    Mallen, Christian
    Roddy, Edward
    [J]. ARTHRITIS & RHEUMATOLOGY, 2019, 71
  • [45] Accuracy of ultrasound-guided injections of thoracolumbar articular process joints in horses: A cadaveric study
    Fuglbjerg, V.
    Nielsen, J. V.
    Thomsen, P. D.
    Berg, L. C.
    [J]. EQUINE VETERINARY JOURNAL, 2010, 42 (01) : 18 - 22
  • [46] Accuracy of Landmark-Guided Glenohumeral Intra-Articular Injections in Patients With Anterior Shoulder Dislocations
    Omer, T.
    Mailhot, T.
    Berona, K.
    Swadron, S.
    Kang, T.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2017, 70 (04) : S133 - S134
  • [47] Accuracy and outcome of sonographically guided intra-articular sodium hyaluronate injections in patients with osteoarthritis of the hip
    Pourbagher, MA
    Ozalay, M
    Pourbagher, A
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (10) : 1391 - 1395
  • [48] High accuracy of intra-articular needle position during anterior landmark guided glenohumeral injections
    Bartels, Douglas
    Pullen, W. Michael
    Curtis, Daniel
    Sherman, Seth L.
    Abrams, Geoffrey D.
    Cheung, Emilie, V
    Freehill, Michael T.
    Wang, Tim
    [J]. JOURNAL OF ISAKOS JOINT DISORDERS & ORTHOPAEDIC SPORTS MEDICINE, 2024, 9 (04) : 534 - 539
  • [49] EFFICACY AND SAFETY OF INTRA-ARTICULAR CORTICOSTEROID ULTRASOUND-GUIDED INJECTION IN EROSIVE HAND OSTEOARTHRITIS
    Favero, M.
    Hoxha, A.
    Frallonardo, P.
    Belluzzi, E.
    Lorenzin, M.
    Ortolan, A.
    Felicetti, M.
    Oliviero, F.
    Punzi, L.
    Ramonda, R.
    [J]. CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2018, 36 (01) : S60 - S60
  • [50] Ultrasound-guided intra-articular tenotomy of the long head of the biceps: a cadaveric feasibility study
    Atlan, Frank
    Werthel, Jean David
    [J]. INTERNATIONAL ORTHOPAEDICS, 2016, 40 (12) : 2567 - 2573