摘要
This paper investigates the feasibility of using Lauric acid as a phase change material (PCM) to store excess solar energy and release it when the energy availability is inadequate or not available for solar drying process. With the increased emphasis on the efficiency of solar heating and drying facilities, the performance of ancillary equipment is becoming increasingly important. The air heater is a source of lost thermal efficiency in two ways - air leakage into dryer side and poor heat recovery. Moreover, air in leak makes it difficult to determine the exiting hot air temperature and the performance of the air heater. In the present study, attention was given on the heat transfer characteristics of the PCM during the charge and discharge periods. The effects of inlet hot air temperature and inlet air velocities on the charge time were determined, while during the discharge period only the effect of inlet ambient air velocity was considered. This study also addresses the issue of properly evaluating the air heater performance and the accuracy of the final result. The appendix discusses the procedures used to determine the individual measurements and the uncertainty of these measurements. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:2360 / 2369
页数:10
相关论文
共 50 条
  • [31] Evaluation of landscape fabric as a solar air heater
    Poole, Mark R.
    Shah, Sanjay B.
    Boyette, Michael D.
    Grimes, Jesse L.
    Stikeleather, Larry E.
    RENEWABLE ENERGY, 2018, 127 : 998 - 1003
  • [32] EVALUATION OF A JET PLATE SOLAR AIR HEATER
    CHOUDHURY, C
    GARG, HP
    SOLAR ENERGY, 1991, 46 (04) : 199 - 209
  • [33] PREDICTION OF SOLAR AIR HEATER THERMAL PERFORMANCE
    PARKER, BF
    COLLIVER, DG
    WALTON, LR
    TRANSACTIONS OF THE ASAE, 1985, 28 (03): : 932 - 936
  • [34] THERMAL PERFORMANCE OF A NEW SOLAR AIR HEATER
    TIRIS, C
    OZBALTA, N
    TIRIS, M
    DINCER, I
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1995, 22 (03) : 411 - 423
  • [35] Analytical approach for evaluation of thermo hydraulic performance of roughened solar air heater
    Gawande, Vipin B.
    Dhoble, A. S.
    Zodpe, D. B.
    Chamoli, Sunil
    CASE STUDIES IN THERMAL ENGINEERING, 2016, 8 : 19 - 31
  • [36] Experimental performance evaluation of an impinging jet with fins type solar air heater
    Abhishek Kumar Goel
    Shailendra Narayan Singh
    Environmental Science and Pollution Research, 2021, 28 : 19944 - 19957
  • [37] Performance evaluation of plastic solar air heater with different cross sectional configuration
    Abdullah, A. S.
    EI-Samadony, Y. A. F.
    Omara, Z. M.
    APPLIED THERMAL ENGINEERING, 2017, 121 : 218 - 223
  • [38] Evaluation of the performance of an improved solar air heater with "S" shaped ribs with gap
    Wang, Dengjia
    Liu, Jin
    Liu, Yanfeng
    Wang, Yingying
    Li, Bojia
    Liu, Jiaping
    SOLAR ENERGY, 2020, 195 : 89 - 101
  • [39] Exergetic performance evaluation of louvered finned solar air heater: an experimental investigation
    Chand, Subhash
    Ghritlahre, Harish Kumar
    Singh, Ajay Partap
    Journal of Engineering and Applied Science, 2024, 71 (01):
  • [40] Thermal performance evaluation of a solar air heater with and without thermal energy storage
    Tyagi, V. V.
    Pandey, A. K.
    Kaushik, S. C.
    Tyagi, S. K.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2012, 107 (03) : 1345 - 1352