Oxygen saturation detection aided with the theory of lock-in amplifier

被引:3
|
作者
Liu, Manjin [1 ]
Hui, Mei [1 ]
Liu, Ming [1 ]
Zhao, Yuejin [1 ]
Dong, Liquan [1 ]
Wu, Hong [1 ]
Liu, Xiaohua [1 ]
Zhao, Zhu [1 ]
Feng, Yun [1 ]
Chen, Di [1 ]
Yang, Lei [2 ]
Zhao, Jingsheng [3 ]
机构
[1] Beijing Inst Technol, Sch Optoelect, Beijing 100081, Peoples R China
[2] Chinese Acad Sci, Acad Opto Elect, Key Lab Computat Optic Imaging Technol, Beijing, Peoples R China
[3] Cent Hosp Peoples Liberat Army, Pingdingshan 467099, Peoples R China
基金
中国国家自然科学基金;
关键词
oxygen saturation; lock-in amplifier; Photoplethysmography (PPG);
D O I
10.1117/12.2059755
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a method to recover the pulse signal with the theory of lock-in amplifier and calculates the oxygen saturation. The pulse signal is obtained based on the method of Photoplethysmography (PPG). We use a LED as the light source and a photoelectric diode as the receiver to get a measured pulse wave. Because the pulse wave obtained by this method is easily disturbed by motion artifact, we use an electrocardiogram (ECG) signal to aid PPG measurement. Firstly, the ECG signal is processed by the Fast Fourier Transform (FFT) and get the heart rate. Secondly, with the value of heart rate, a typical noise free pulse waveform can be constructed. Finally, we use it as a reference input to get a recovered pulse wave by the theory of lock-in amplifier. Thus, the value of oxygen saturation can be calculated accurately through two recovered pulse waveforms of red (660nm) and infrared (940nm) light. Some volunteers were tested. The correlation coefficient between the experimental data and the data provided by a reference instrument is 0.98, proving that this method has high reliability and utility in motion.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Application of Lock-in Amplifier to Weak Magnetic Field Detection
    Song, Hengli
    Dong, Haobin
    Zhang, Lin
    [J]. PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHATRONICS, ELECTRONIC, INDUSTRIAL AND CONTROL ENGINEERING, 2014, 5 : 1092 - 1096
  • [12] Solar Cell Defects Detection using Lock-In Amplifier
    Leong, Iat-Fai
    Fang, Jing-Jing
    Liao, Joseph
    [J]. RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 276 - +
  • [13] Response of a lock-in amplifier to noise
    Van Baak, D. A.
    Herold, George
    [J]. AMERICAN JOURNAL OF PHYSICS, 2014, 82 (08) : 785 - 797
  • [14] Quantum double lock-in amplifier
    Chen, Sijie
    Zhuang, Min
    Fang, Ruihuang
    Chen, Yun
    Han, Chengyin
    Lu, Bo
    Huang, Jiahao
    Lee, Chaohong
    [J]. COMMUNICATIONS PHYSICS, 2024, 7 (01):
  • [15] Implementation of Digital Lock-in Amplifier
    Bhattacharyya, Sabyasachi
    Ahmed, Ragib Nasir
    Purkayastha, Basab Bijoy
    Bhattacharyya, Kaustubh
    [J]. XXVII IUPAP CONFERENCE ON COMPUTATIONAL PHYSICS (CCP2015), 2016, 759
  • [16] THE LOCK-IN AMPLIFIER - A STUDENT EXPERIMENT
    WOLFSON, R
    [J]. AMERICAN JOURNAL OF PHYSICS, 1991, 59 (06) : 569 - 572
  • [17] SIMULATION OF A DIGITAL LOCK-IN AMPLIFIER
    DENING, DC
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1976, 23 (03) : 461 - 463
  • [18] An integrated CMOS dual lock-in amplifier for optoelectronic antigens detection
    Hong, Nam-Pyo
    Kim, Do-Gyun
    Jung, In-Il
    Son, Ho-Hyun
    Chung, Tae-Kyoung
    Choi, Young-ki
    Choi, Young-Wan
    [J]. OPTICAL DIAGNOSTICS AND SENSING X: TOWARD POINT-OF-CARE DIAGNOSTICS, 2010, 7572
  • [19] Design of Lock-In Amplifier in the Optical Fiber Methane Harmonic Detection
    Wang Wen-qing
    Zhang Wei-hua
    Wang Lei
    Zhang Lei
    Jiang Ling
    Liu Xiao-lu
    [J]. 2014 Fifth International Conference on Intelligent Systems Design and Engineering Applications (ISDEA), 2014, : 367 - 370
  • [20] Design of Digital Lock-In Amplifier for Low Concentration Gas Detection
    Rahmannuri, Handi
    Rivai, Muhammad
    Sardjono, Tri Arief
    [J]. 2017 INTERNATIONAL SEMINAR ON INTELLIGENT TECHNOLOGY AND ITS APPLICATIONS (ISITIA), 2017, : 319 - 322