Oxygen saturation detection aided with the theory of lock-in amplifier

被引:3
|
作者
Liu, Manjin [1 ]
Hui, Mei [1 ]
Liu, Ming [1 ]
Zhao, Yuejin [1 ]
Dong, Liquan [1 ]
Wu, Hong [1 ]
Liu, Xiaohua [1 ]
Zhao, Zhu [1 ]
Feng, Yun [1 ]
Chen, Di [1 ]
Yang, Lei [2 ]
Zhao, Jingsheng [3 ]
机构
[1] Beijing Inst Technol, Sch Optoelect, Beijing 100081, Peoples R China
[2] Chinese Acad Sci, Acad Opto Elect, Key Lab Computat Optic Imaging Technol, Beijing, Peoples R China
[3] Cent Hosp Peoples Liberat Army, Pingdingshan 467099, Peoples R China
基金
中国国家自然科学基金;
关键词
oxygen saturation; lock-in amplifier; Photoplethysmography (PPG);
D O I
10.1117/12.2059755
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a method to recover the pulse signal with the theory of lock-in amplifier and calculates the oxygen saturation. The pulse signal is obtained based on the method of Photoplethysmography (PPG). We use a LED as the light source and a photoelectric diode as the receiver to get a measured pulse wave. Because the pulse wave obtained by this method is easily disturbed by motion artifact, we use an electrocardiogram (ECG) signal to aid PPG measurement. Firstly, the ECG signal is processed by the Fast Fourier Transform (FFT) and get the heart rate. Secondly, with the value of heart rate, a typical noise free pulse waveform can be constructed. Finally, we use it as a reference input to get a recovered pulse wave by the theory of lock-in amplifier. Thus, the value of oxygen saturation can be calculated accurately through two recovered pulse waveforms of red (660nm) and infrared (940nm) light. Some volunteers were tested. The correlation coefficient between the experimental data and the data provided by a reference instrument is 0.98, proving that this method has high reliability and utility in motion.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] COMMENTS ON LOCK-IN DETECTION WITH NMR SATURATION IN SOLIDS
    WOLLAN, DS
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (05): : 682 - &
  • [2] The Application of Lock-in Amplifier in Weak Signal Detection
    Zhang, Jiatian
    Liu, Gang
    [J]. MEMS, NANO AND SMART SYSTEMS, PTS 1-6, 2012, 403-408 : 2650 - 2653
  • [3] Lock-in Amplifier Dairy Sensor for Detection of Ciprofloxacin
    Devasagayam, Jasen
    Leclerc, Camille A.
    Bosma, Rick
    Wood, Larry
    Collier, Christopher M.
    [J]. IEEE ACCESS, 2023, 11 : 41697 - 41707
  • [4] AN IMPROVED LOCK-IN AMPLIFIER
    MICHELS, WC
    REDDING, ED
    [J]. PHYSICAL REVIEW, 1948, 74 (10): : 1562 - 1562
  • [5] INEXPENSIVE LOCK-IN AMPLIFIER
    CAPLAN, LC
    STERN, R
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (05): : 689 - &
  • [6] AN IMPROVED LOCK-IN AMPLIFIER
    COX, HL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1953, 24 (04): : 307 - 308
  • [7] Spreadsheet lock-in amplifier
    Wolfson, Richard
    Mullen, Darcy
    [J]. AMERICAN JOURNAL OF PHYSICS, 2010, 78 (11) : 1227 - 1229
  • [8] A chaotic lock-in amplifier
    Spears, Brian K.
    Tufillaro, Nicholas B.
    [J]. AMERICAN JOURNAL OF PHYSICS, 2008, 76 (03) : 213 - 217
  • [9] AN IMPROVED LOCK-IN AMPLIFIER
    COX, HL
    [J]. PHYSICAL REVIEW, 1952, 86 (04): : 640 - 640
  • [10] The signal detection technology of photoconductive detector with lock-in amplifier
    Wang Yang
    Zhang Yani
    He Xiangrong
    Fang Guangyu
    Gong Haimei
    [J]. SELECTED PAPERS FROM CONFERENCES OF THE PHOTOELECTRONIC TECHNOLOGY COMMITTEE OF THE CHINESE SOCIETY OF ASTRONAUTICS 2014, PT II, 2015, 9522