Glomerular filtration rate estimation for carboplatin dosing in patients with gynaecological cancers

被引:2
|
作者
Samani, A. [1 ,2 ]
Bennett, R. [2 ]
Eremeishvili, K. [3 ]
Kalofonou, F. [2 ]
Whear, S. [1 ]
Montes, A. [3 ]
Kristeleit, R. [3 ]
Krell, J. [1 ,2 ]
McNeish, I [1 ,2 ]
Ghosh, S. [3 ]
Tookman, L. [1 ,2 ]
机构
[1] Imperial Coll London, Dept Surg & Canc, London, England
[2] Imperial Coll Healthcare NHS Trust, Dept Med Oncol, London, England
[3] Guys & St ThomasNHS Fdn Trust, Guys Canc Ctr, London, England
关键词
gynaecological cancers; chemotherapy; carboplatin; glomerular filtration rate; toxicity; CREATININE; PHARMACOKINETICS; CLEARANCE; EQUATION; OVARIAN;
D O I
10.1016/j.esmoop.2022.100401
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Carboplatin remains integral for treatment of gynaecological malignancies and dosing is based on glomerular filtration rate (GFR). Measurement via radiotracer decay [nuclear medicine GFR (nmGFR)] is ideal. However, this may be unavailable. Therefore GFR is often estimated using formulae that have not been validated in patients with cancer and/or specifically for gynaecological malignancies, leading to debate over optimal estimation. Suboptimal GFR estimation may affect efficacy or toxicity. Methods: We surveyed several UK National Health Service Trusts to assess carboplatin dosing practise. We then explored single-centre accuracy, bias and precision of various formulae for GFR estimation, relative to nmGFR, before validating our findings in an external cohort. Results: Across 18 Trusts, there was considerable heterogeneity in GFR estimation, including the formulae used [CockcrofteGault (CG) versus Wright], weight adjustment and area under the curve (AUC; 5 versus 6). We analysed 274 and 192 patients in two centres. Overall, CamGFR v2 (a novel formula for GFR estimation developed at Cambridge University Hospitals NHS Foundation Trust) excelled, showing the highest accuracy and precision. This translated into accuracy of hypothetical carboplatin dosing; nmGFR-derived carboplatin dose fell within 20% of the Cam GFR v2-derived dose in 86.5% and 87% of patients across the cohorts. Among the CG formula and its derivatives, using adjusted body weight in those with body mass index >= 25 kg/m(2) [CG-adjusted body weight (CGAdBW)] was optimal. The Wright and unadjusted CG estimators performed most poorly. Conclusions: When compared with nmGFR assessment, accuracy, bias and precision varied widely between GFR estimators, with the newly developed Cam GFR v2 and CG-AdBW performing best. In general, weight (or body surface area)-adjusted formulae excelled, while the unadjusted CG and Wright formulae or the use of AUC6 (versus nmGFR AUC5) produced risk of significant overdose. Thus, individual centres should validate their GFR estimation methods. In the absence of validation, CG-AdBW or CamGFR v2 is likely to perform well while unadjusted CG/ Wright formulae or AUC6 dosing should be avoided.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Accuracy of glomerular filtration rate estimation equations in patients with hematopathy
    Sun, Han
    Pei, Xiaohua
    Wu, Jianqing
    Zhao, Weihong
    JOURNAL OF BIOMEDICAL RESEARCH, 2019, 33 (01): : 46 - 55
  • [42] Bedside estimation of the glomerular filtration rate in hospitalized elderly patients
    Burkhardt, H
    Hahn, T
    Gretz, N
    Gladisch, R
    NEPHRON CLINICAL PRACTICE, 2005, 101 (01): : C1 - C8
  • [43] Analysis of carboplatin dosing in patients with a glomerular filtration rate greater than 125 mL/min: To cap or not to cap? A retrospective analysis and review
    Morrow, Amy
    Garland, Campbell
    Yang, Fei
    De Luna, Mike
    Herrington, Jon D.
    JOURNAL OF ONCOLOGY PHARMACY PRACTICE, 2019, 25 (07) : 1651 - 1657
  • [44] Can estimated glomerular filtration rate (eGFR) replace isotopic measurement of GFR for carboplatin dosing in stage 1 seminoma?
    Shepherd, Scott T. C.
    Gillen, Gerry
    Morrison, Paula
    Forte, Carla
    MacPherson, Iain R.
    Mark, Patrick
    White, Jeff D.
    JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (15)
  • [45] Exploration of renal glomerular function: estimation of glomerular filtration rate
    Maillard, Nicolas
    Delanaye, Pierre
    Mariat, Christophe
    NEPHROLOGIE & THERAPEUTIQUE, 2015, 11 (01): : 54 - 67
  • [46] Accurately simple estimation of glomerular filtration rate in kidney transplant patients
    Manotham, K
    Booranalertpaisarn, V
    Eiam-Ong, S
    Chusil, S
    Praditpornsilpa, K
    Tungsanga, K
    TRANSPLANTATION PROCEEDINGS, 2002, 34 (04) : 1148 - 1151
  • [47] Can Glomerular Filtration Rate Estimation be Adapted for Local Oncology Patients?
    Holness, J. L.
    Simonds, H. M.
    Barnardt, P.
    Warwick, J. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S512 - S512
  • [48] Estimation of Glomerular Filtration Rate in Obese Patients: Utility of a New Equation
    Fernandez, Pehuen
    Nores, Maria Laura
    Douthat, Walter
    de Arteaga, Javier
    Lujan, Pablo
    Campazzo, Mario
    de La Fuente, Jorge
    Chiurchiu, Carlos
    NUTRIENTS, 2023, 15 (05)
  • [49] Estimation of Glomerular Filtration Rate: What Are the Pitfalls?
    Fesler, Pierre
    Mimran, Albert
    CURRENT HYPERTENSION REPORTS, 2011, 13 (02) : 116 - 121
  • [50] Assessment of the application of the estimation glomerular filtration rate
    Pan, B.
    Wu, J.
    Guo, W.
    Gao, X.
    Shi, H.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A37 - A37