Biodegradable Polymer-Based Sirolimus-Eluting Stents With Differing Elution and Absorption Kinetics The PANDA III Trial

被引:43
|
作者
Xu, Bo [1 ]
Gao, Runlin [1 ]
Yang, Yuejin [1 ]
Cao, Xuebin [2 ]
Qin, Lei [3 ]
Li, Yi [4 ]
Li, Zhanquan [5 ]
Li, Xueqi [6 ]
Lin, Hailong [7 ]
Guo, Yong [8 ]
Ma, Yitong [9 ]
Wang, Jian'an [10 ]
Nie, Shaoping [11 ]
Xu, Liang [1 ]
Cao, Eric [12 ]
Guan, Changdong [1 ]
Stone, Gregg W. [13 ,14 ]
机构
[1] Chinese Acad Med Sci, Natl Ctr Cardiovasc Dis, Fu Wai Hosp, Dept Cardiol, Beijing 100730, Peoples R China
[2] Chinese PLA 252 Hosp, Dept Cardiol, Baoding, Peoples R China
[3] Kaifeng Cent Hosp, Dept Cardiol, Kaifeng, Peoples R China
[4] Yunnan St Johns Hosp, Dept Cardiol, Kunming, Peoples R China
[5] Liaoning Prov Peoples Hosp, Dept Cardiol, Shenyang, Peoples R China
[6] Haerbin Med Univ, Affiliated Hosp 4, Dept Cardiol, Haerbin, Peoples R China
[7] Dalian Municipal Cent Hosp, Dept Cardiol, Dalian, Peoples R China
[8] Dazhou Cent Hosp, Dept Cardiol, Dazhou, Peoples R China
[9] Xinjiang Med Univ, Affiliated Hosp 1, Dept Cardiol, Urumqi, Peoples R China
[10] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Dept Cardiol, Hangzhou 310003, Zhejiang, Peoples R China
[11] Capital Med Univ, Affiliated Anzhen Hosp, Dept Cardiol, Beijing, Peoples R China
[12] Res & Dev Sino Med, Tianjin, Peoples R China
[13] Columbia Univ, Med Ctr, Dept Med, New York Presbyterian Hosp, New York, NY USA
[14] Cardiovasc Res Fdn, New York, NY USA
关键词
COMPREHENSIVE NETWORK METAANALYSIS; CLINICAL-OUTCOMES; THROMBOSIS; REDUCTION; SAFETY; RISK;
D O I
10.1016/j.jacc.2016.03.475
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Whether the rate of drug elution and polymer absorption affects clinical outcomes of biodegradable polymer-based drug-eluting stents (DES) is unknown. The widely used polylactide polymer-based Excel stent (JW Medical, Weihai, China) elutes sirolimus within 180 days, and the polylactide polymer is completely absorbed within 6 to 9 months. In contrast, the poly-lactide-co-glycolide polymer-based BuMA stent (Sino Medical, Tianjin, China) elutes sirolimus within 30 days, and the poly-lactide-co-glycolide polymer is completely absorbed within 3 months. Thus, both metallic DES elute sirolimus, isolating major differences to the polymer and elution kinetics. OBJECTIVES The goal of this study was to compare the safety and effectiveness between the BuMA sirolimus-eluting stent (SES) and Excel SES in an "all-comers" population. METHODS PANDA III was a multicenter trial with few exclusion criteria, powered for sequential noninferiority and superiority testing. The primary endpoint was 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization. RESULTS Between December 2013 and August 2014, 2,348 patients were randomly assigned to treatment with BuMA (n = 1,174) or Excel SES (n = 1,174). The 1-year primary endpoint of TLF occurred in 6.4% of patients in each group (difference: 0.06%; 95% confidence interval: 1.93% to 2.04%; pnoninferiority = 0.0003; psuperiority = 0.95). There were no significant between-group differences in any of the secondary endpoints other than the incidence of definite/probable stent thrombosis, which occurred less frequently with the BuMA stent (0.5% vs. 1.3%; log-rank p = 0.048). CONCLUSIONS The BuMA SES was demonstrated to be noninferior to the Excel SES for 1-year TLF, with a lower incidence of stent thrombosis. (Comparison of BuMA eG Based BioDegradable Polymer Stent With EXCEL Biodegradable Polymer Sirolimus-eluting Stent in "Real-World" Practice [PANDA-III]; NCT02017275) (C) 2016 by the American College of Cardiology Foundation.
引用
收藏
页码:2249 / 2258
页数:10
相关论文
共 50 条
  • [1] Two Biodegradable Polymer-Based Sirolimus-Eluting Stents with Differing Elution and Absorption Kinetics: Two-Year Outcomes of the PANDA III Trial
    Guan, Changdong
    Xu, Bo
    Gao, Runlin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B182 - B182
  • [2] Biodegradable Polymer-Based Sirolimus-Eluting Stents With Differing Elution and Absorption Kinetics: The PANDA Ill Trial (vol 67, pg 2249, 2016)
    Xu, B.
    Gao, R.
    Yang, Y.
    Cao, X.
    Qin, L.
    Li, Y.
    Li, Z.
    Li, X.
    Lin, H.
    Guo, Y.
    Ma, Y.
    Wang, J.
    Nie, S.
    Xu, L.
    Cao, E.
    Guan, C.
    Stone, G. W.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (01) : 135 - 135
  • [3] Comparison between two biodegradable polymer-based sirolimus-eluting stents with differing drug elution and polymer absorption kinetics: two-year clinical outcomes of the PANDA III trial
    Wang, Juan
    Guan, Changdong
    Qiao, Shubin
    Cao, Xuebin
    Qin, Lei
    Li, Yi
    Li, Zhanquan
    Li, Xueqi
    Yuan, Jiansong
    Gao, Runlin
    Xu, Bo
    EUROINTERVENTION, 2018, 14 (09) : E1029 - E1037
  • [4] Comparison of Two Biodegradable Polymer-Based Sirolimus-Eluting Stents with Varying Elution and Absorption Kinetics in Acute Myocardial Infarction Patients: A Subgroup Analysis of PANDA III Trial
    Guan, Changdong
    Xu, Bo
    Gao, Runlin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B185 - B186
  • [5] Comparison of Two Biodegradable-Polymer-Based Sirolimus-Eluting Stents With Varying Elution and Absorption Kinetics in Patients With Acute Myocardial Infarction: A Subgroup Analysis of the PANDA III Trial
    Guan, Changdong
    Xu, Bo
    Qiao, Shubin
    Qin, Lei
    Li, Yi
    Li, Zhanquan
    Guo, Yong
    Sun, Zhongwei
    Song, Lei
    Gao, Runlin
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 : 520 - 527
  • [6] Safety Evaluation of the Biodegradable Polymer-Based Sirolimus-Eluting Stent with Faster Drug Eluting Rate and Polymer Absorption Kinetics in Complex Patient and Lesion Subgroup of the PANDA III Trial
    Jia, Sida
    Guan, Changdong
    Yuan, Jinqing
    Gao, Runlin
    Leon, Martin
    Xu, Bo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B266 - B266
  • [7] Safety and Efficacy of New Biodegradable Polymer-based Sirolimus-Eluting Stents in a Preclinical Model
    Perez de Prado, Armando
    Perez Martinez, Claudia
    Cuellas Ramon, Carlos
    Regueiro Purrinos, Marta
    Lopez Benito, Maria
    Gonzalo Orden, Jose Manuel
    Rodriguez Altonaga, Jose Antonio
    Estevez Loureiro, Rodrigo
    Benito Gonzalez, Tomas
    Vinuela Baragano, David
    Molina Crisol, Maria
    Amoros Aguilar, Marc
    Perez Serranos, Isabel
    Vidal Parreu, Arnau
    Benavides Montegordo, Ana
    Duocastella Codina, Luis
    Fernandez Vazquez, Felipe
    REVISTA ESPANOLA DE CARDIOLOGIA, 2017, 70 (12): : 1059 - 1066
  • [8] Superiority of biodegradable polymer sirolimus-eluting stents in STEMI
    von Birgelen, Clemens
    Buiten, Rosaly Anne
    LANCET, 2019, 394 (10205): : 1208 - 1210
  • [9] Open-labeled randomized controlled trial to evaluate the 1-year clinical outcomes of polymer-free sirolimus-eluting coronary stents as compared with biodegradable polymer-based sirolimus-eluting coronary stents
    Viswanathan, Sunitha
    Gopinath, Kiran
    Koshy, George
    Gupta, Prabha Nini
    Velappan, Praveen
    INDIAN HEART JOURNAL, 2018, 70 : S323 - S328
  • [10] Efficacy and safety of domestic biodegradable polymer sirolimus-eluting stents and durable polymer sirolimus-eluting stents in the treatment of coronary artery disease
    Fang, Yi
    Bin, Wang
    Jing, Li
    Qiu Miaohan
    Han Yaling
    Shuang, Wang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (16) : C106 - C107