Safety and Efficacy of New Biodegradable Polymer-based Sirolimus-Eluting Stents in a Preclinical Model

被引:0
|
作者
Perez de Prado, Armando [1 ,2 ]
Perez Martinez, Claudia [1 ,2 ]
Cuellas Ramon, Carlos [1 ,2 ]
Regueiro Purrinos, Marta [1 ,2 ]
Lopez Benito, Maria [1 ,2 ]
Gonzalo Orden, Jose Manuel [1 ,2 ]
Rodriguez Altonaga, Jose Antonio [1 ,2 ]
Estevez Loureiro, Rodrigo [1 ,2 ]
Benito Gonzalez, Tomas [1 ,2 ]
Vinuela Baragano, David [1 ,2 ]
Molina Crisol, Maria [3 ]
Amoros Aguilar, Marc [3 ]
Perez Serranos, Isabel [3 ]
Vidal Parreu, Arnau [3 ]
Benavides Montegordo, Ana [3 ]
Duocastella Codina, Luis [3 ]
Fernandez Vazquez, Felipe [1 ,2 ]
机构
[1] Univ Leon, Hosp Univ Leon, Grp Cardiovasc HemoLeon, Fdn Invest Sanitaria Leon, Leon, Spain
[2] Univ Leon, Hosp Univ Leon, Inst Biomed IBIOMED, Leon, Spain
[3] iVascular, LVD Biotech, Barcelona, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2017年 / 70卷 / 12期
关键词
Preclinical model; Drug-eluting stent; Restenosis; Vascular healing; BARE-METAL STENTS; CORONARY STENTS; PORCINE MODEL; INFLAMMATION; PACLITAXEL; PATHOLOGY; RECOVERY; SOCIETY; TRIAL;
D O I
10.1016/j.recesp.2017.02.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: New drug-eluting stents (DES) designed to overcome the limitations of existing devices should initially be tested in preclinical studies. Our objective was to analyze the safety and efficacy of new biodegradable polymer-based DES compared with bare-metal stents (BMS) and commercially available DES in a model of normal porcine coronary arteries. Methods: We randomly implanted 101 stents (BMS and biodegradable polymer-based sirolimus-eluting stents: 3 test stent iterations [BD1, BD2, and BD3], Orsiro, Biomime and Biomatrix) in the coronary arteries of 34 domestic pigs. Angiographic and histomorphometric studies were conducted 1 month (n = 83) and 3 months (n = 18) later. Results: The stents were implanted at a stent/artery ratio of 1.31 +/- 0.21, with no significant differences between groups. At 1 month, the new test stents (BD1, BD2 and BD3) showed less late loss and angiographic restenosis, as well as lower histologic restenosis and neointimal area (P < .0005), than the BMS. There were no differences in endothelialization, vascular injury, or inflammation between the new test stents and BMS, although the new stents showed higher fibrin deposition (P = .0006). At 3 months, all these differences disappeared, except for a lower neointimal area with the new BD1 stent (P = .027). No differences at any time point were observed between the new test stents and commercially available controls. Conclusions: In this preclinical model, the new biodegradable polymer-based DES studied showed less restenosis than BMS and no significant differences in safety of efficacy vs commercially available DES. (C) 2017 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:1059 / 1066
页数:8
相关论文
共 50 条
  • [1] Efficacy and safety of domestic biodegradable polymer sirolimus-eluting stents and durable polymer sirolimus-eluting stents in the treatment of coronary artery disease
    Fang, Yi
    Bin, Wang
    Jing, Li
    Qiu Miaohan
    Han Yaling
    Shuang, Wang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (16) : C106 - C107
  • [2] Superiority of biodegradable polymer sirolimus-eluting stents in STEMI
    von Birgelen, Clemens
    Buiten, Rosaly Anne
    LANCET, 2019, 394 (10205): : 1208 - 1210
  • [3] Biodegradable Polymer-Based Sirolimus-Eluting Stents With Differing Elution and Absorption Kinetics The PANDA III Trial
    Xu, Bo
    Gao, Runlin
    Yang, Yuejin
    Cao, Xuebin
    Qin, Lei
    Li, Yi
    Li, Zhanquan
    Li, Xueqi
    Lin, Hailong
    Guo, Yong
    Ma, Yitong
    Wang, Jian'an
    Nie, Shaoping
    Xu, Liang
    Cao, Eric
    Guan, Changdong
    Stone, Gregg W.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (19) : 2249 - 2258
  • [4] Efficacy and safety of biodegradable polymer sirolimus-eluting stents versus durable polymer drug-eluting stents: A meta-analysis of randomized trials
    Yang, Yunjing
    Lei, Jiayan
    Huang, Wei
    Lei, Han
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 222 : 486 - 493
  • [5] Safety and Efficacy of New Sirolimus-eluting Stent Models in a Preclinical Study
    Estevez-Loureiro, Rodrigo
    Perez de Prado, Armando
    Perez-Martinez, Claudia
    Cuellas-Ramon, Carlos
    Regueiro-Purrinos, Marta
    Gonzalo-Orden, Jose M.
    Lopez-Benito, Maria
    Molina-Crisol, Maria
    Duocastella-Codina, Luis
    Fernandez-Vazquez, Felipe
    REVISTA ESPANOLA DE CARDIOLOGIA, 2015, 68 (12): : 1118 - 1124
  • [6] Clinical Efficacy and Safety of Biodegradable Polymer-Based Sirolimus-Eluting Stents in Patients with Diabetes Mellitus Insight From the 4-year Results of the CREATE Study
    Li, Yi
    Han, Yaling
    Zhang, Lei
    Jing, Quanmin
    Wang, Xiaozeng
    Yan, Gaoliang
    Ma, Yingyan
    Wang, Geng
    Wang, Shouli
    Chen, Xuezhi
    Yang, Lixia
    Zhu, Guoying
    Liu, Huiliang
    Jiang, Tieming
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (07) : 1127 - 1133
  • [7] Safety and Efficacy of Everolimus-Eluting Stents Versus Sirolimus-Eluting Stents in Women
    Badr, Salem
    Barbash, Israel M.
    Pvir, Danny
    Torguson, Rebecca
    Xue, Zhenyi
    Kitabata, Hironori
    Sardi, Gabriel
    Loh, Joshua P.
    Pichard, Augusto D.
    Waksman, Ron
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (01): : 21 - 25
  • [8] Open-labeled randomized controlled trial to evaluate the 1-year clinical outcomes of polymer-free sirolimus-eluting coronary stents as compared with biodegradable polymer-based sirolimus-eluting coronary stents
    Viswanathan, Sunitha
    Gopinath, Kiran
    Koshy, George
    Gupta, Prabha Nini
    Velappan, Praveen
    INDIAN HEART JOURNAL, 2018, 70 : S323 - S328
  • [9] Safety and efficacy of polymer-based paclitaxel-eluting stents
    Claire Braybrook
    Nature Clinical Practice Cardiovascular Medicine, 2006, 3 (2): : 64 - 64
  • [10] Safety and efficacy of overlapping sirolimus-eluting versus paclitaxel-eluting stents
    Shishehbor, Mehdi H.
    Amini, Reza
    Raymond, Russell E.
    Bavry, Anthony A.
    Brener, Sorin J.
    Kapadia, Samir R.
    Whitlow, Patrick L.
    Ellis, Stephen G.
    Bhatt, Deepak L.
    AMERICAN HEART JOURNAL, 2008, 155 (06) : 1075 - 1080