A Novel Operation Scheme for Modular Multilevel Converter With Enhanced Ride-Through Capability of Submodule Faults

被引:27
|
作者
Xiao, Qian [1 ,2 ]
Wang, Jinyu [3 ]
Jin, Yu [4 ]
Chen, Linglin [5 ]
Jia, Hongjie [1 ,2 ]
Dragicevic, Tomislav [6 ]
Teodorescu, Remus [6 ]
机构
[1] Tianjin Univ, Minist Educ, Key Lab Smart Grid, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Tianjin Key Lab Smart Energy & Informat Technol, Tianjin 300072, Peoples R China
[3] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[4] Harbin Inst Technol, Dept Elect Engn & Automat, Harbin 150001, Peoples R China
[5] Univ Nottingham, Dept Elect & Elect Engn, Nottingham NG7 2RD, England
[6] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
基金
中国国家自然科学基金;
关键词
Fault tolerance; Fault tolerant systems; Voltage control; Capacitors; Modulation; Control systems; Current control; Fault-tolerant control; modular multilevel converter (MMC); submodule (SM) fault; virtual voltage; zero-sequence voltage (ZSV);
D O I
10.1109/JESTPE.2020.2967576
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Submodule (SM) fault is a common potential problem in the modular multilevel converter (MMC), which may lead to current distortion and even the collapse of the control system. This article proposes a novel operation scheme for SM fault in medium-voltage MMC applications. First, when the fault number is low, the capacitor voltages increase to a lower value according to the operation status. Second, when the fault number is higher, the capacitor voltages increase to the rated value and the zero-sequence voltage (ZSV) is injected to maintain the normal operation of MMC. In addition, a virtual voltage idea is applied to simplify the modulation under SM faults, where the reconfigurations of carriers are not necessary. Compared with the conventional fault-tolerant method, the proposed method can enhance the ride-through capability of MMC and simplify the modulation process under SM faults. Simulation and experimental results verify the effectiveness of the proposed operation scheme under severe SM faults.
引用
收藏
页码:1258 / 1268
页数:11
相关论文
共 50 条
  • [21] A Novel Four Terminal Integrated Submodule Modular Multilevel Converter
    Mishra, Rahul
    Agarwal, Vivek
    2018 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2018,
  • [22] A Multiplexed Modular Multilevel Converter Based Battery Energy Storage System with DC Short-Circuit Fault Ride-through Capability
    Yan, Yinyu
    Sun, Yichao
    Fan, Zhiyuan
    Teixeira, Carlos Alberto
    Hu, Minqiang
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2025, 10 (02) : 54 - 68
  • [23] A cross connected cell based modular multilevel converter for HVDC system with DC short-circuit fault ride-through capability
    Kumar, Ambati Dinesh
    Sreenivasarao, Dharmavarapu
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2024, 52 (08) : 3951 - 3966
  • [24] A Novel Fault-Tolerant Operation Approach for the Modular Multilevel Converter-Based STATCOM With the Enhanced Operation Capability
    Jin, Yu
    Xiao, Qian
    Pou, Josep
    Jia, Hongjie
    Ji, Yanchao
    Teodorescu, Remus
    Blaabjerg, Frede
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2022, 10 (05) : 5541 - 5552
  • [25] DC fault ride-through capability and STATCOM operation of a HVDC hybrid voltage source converter
    Feldman, Ralph
    Farr, Ewan
    Watson, Alan J.
    Clare, Jon C.
    Wheeler, Patrick W.
    Trainer, David R.
    Crookes, R. Will
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (01) : 114 - 120
  • [26] A Submodule Fault-Tolerant Operation Scheme of Modular Multilevel Converters Through Novel Cold and Hot Mixed Topology
    Geng, Zhi
    Yang, Yong
    Xiao, Yang
    Xie, Wenqiang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (04) : 2470 - 2481
  • [27] Fault Ride-through Control Strategy of Modular Multilevel Matrix Converter for Fractional Frequency Transmission System
    Sun Y.
    Wang T.
    Fu C.
    Guo F.
    Ni Q.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (01): : 19 - 30
  • [28] Voltage Fluctuation Based Monitoring Scheme of Submodule Capacitors in Modular Multilevel Converter
    Jia, Hefei
    Deng, Zhaozhe
    Qu, Jinpeng
    Deng, Yan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (03) : 1938 - 1948
  • [29] Principle, Control and Comparison of Modular Multilevel Converters (MMCs) with DC Short Circuit Fault Ride-through Capability
    Cui, Shenghui
    Kim, Sungmin
    Jung, Jae-Jung
    Sul, Seung-Ki
    2014 TWENTY-NINTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2014, : 610 - +
  • [30] T-type Alternate Arm Multilevel Converter with Fault Ride-through Capability and Its Modulation Strategy
    Fan S.
    Yang H.
    Yang H.
    Li W.
    Zhao R.
    Xu F.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (08): : 41 - 50