On-line determination of reaction completion in a closed-loop hydrogenator using NIR spectroscopy

被引:0
|
作者
Howard, WW
Sekulic, S
Wheeler, MJ
Taber, G
Urbanski, FJ
Sistare, FE
Norris, T
Aldridge, PK
机构
[1] Pfizer Inc, Cent Res, Groton, CT 06340 USA
[2] Pfizer US Pharmaceut Grp, Groton, CT 06340 USA
关键词
NIR; near-IR; near-infrared; pharmaceutical; hydrogenation; multivariate calibration; PLS;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An on-line near-infrared (NIR) spectroscopic method has been developed to determine iii situ the endpoint of a bulk pharmaceutical hydrogenation reaction in a loop hydrogenator, This hydrogenation employs a 5% palladium-on-carbon catalyst with tetrahydrofuran (THF) as the reaction solvent, The traditional test for monitoring the endpoint of the hydrogenation is a gas chromatographic procedure that requires an estimated 60 min from the time a sample is taken to the point where the analysis results become available. The use of NIR spectroscopy in an on-line mode of operation allows spectra to be collected every 2 min and thereby significantly improves response time and result availability. The need for obtaining results in "real time" stems from the creation of undesired side products if the reaction is allowed to continue past the optimal endpoint. If the reaction is not stopped before these side products reach a level of approximately 0.8% (wt/wt), the batch requires additional purification at considerable time and cost. A partial least-squares model was constructed, validated, and successfully used to determine the endpoint of subsequent batches.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 50 条
  • [21] Developing an EEG-based on-line closed-loop lapse detection and mitigation system
    Wang, Yu-Te
    Huang, Kuan-Chih
    Wei, Chun-Shu
    Huang, Teng-Yi
    Ke, Li-Wei
    Lin, Chin-Teng
    Cheng, Chung-Kuan
    Jung, Tzyy-Ping
    FRONTIERS IN NEUROSCIENCE, 2014, 8
  • [22] Closed-loop Step Response Identification for Improving On-line Autotuning of Load Disturbance Rejection
    Liu Tao
    2011 30TH CHINESE CONTROL CONFERENCE (CCC), 2011, : 6328 - 6333
  • [23] Safety improvement of a Grignard reaction using on-line NIR monitoring
    Wiss, J
    Länzlinger, M
    Wermuth, M
    ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2005, 9 (03) : 365 - 371
  • [24] CLOSED-LOOP INTRACAVITY PHOTOACOUSTIC OVERTONE SPECTROSCOPY
    MOYLAN, CR
    VIBRATIONAL SPECTROSCOPY, 1991, 1 (04) : 377 - 381
  • [25] Quick statistics on-line determination of the octane number of petroleum samples by NIR spectroscopy
    Schoenkopf, S.
    Chemie-Technik (Heidelberg), 1998, 27 (04):
  • [26] On-Line Monitoring of A Granulation Process By NIR Spectroscopy
    Alcala, Manel
    Blanco, Marcelo
    Bautista, Manel
    Gonzalez, Josep M.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 99 (01) : 336 - 345
  • [27] Qualitative analysis of oil sand slurries using on-line NIR spectroscopy
    Friesen, WI
    APPLIED SPECTROSCOPY, 1996, 50 (12) : 1535 - 1540
  • [28] Phase Margin Determination in a Closed-Loop Configuration
    von Wangenheim, Lutz
    CIRCUITS SYSTEMS AND SIGNAL PROCESSING, 2012, 31 (06) : 1917 - 1926
  • [29] Phase Margin Determination in a Closed-Loop Configuration
    Lutz von Wangenheim
    Circuits, Systems, and Signal Processing, 2012, 31 : 1917 - 1926
  • [30] Closed-loop search method for on-line automatic calibration of multi-camera inspection systems
    Tao, Y