On-line determination of reaction completion in a closed-loop hydrogenator using NIR spectroscopy

被引:0
|
作者
Howard, WW
Sekulic, S
Wheeler, MJ
Taber, G
Urbanski, FJ
Sistare, FE
Norris, T
Aldridge, PK
机构
[1] Pfizer Inc, Cent Res, Groton, CT 06340 USA
[2] Pfizer US Pharmaceut Grp, Groton, CT 06340 USA
关键词
NIR; near-IR; near-infrared; pharmaceutical; hydrogenation; multivariate calibration; PLS;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An on-line near-infrared (NIR) spectroscopic method has been developed to determine iii situ the endpoint of a bulk pharmaceutical hydrogenation reaction in a loop hydrogenator, This hydrogenation employs a 5% palladium-on-carbon catalyst with tetrahydrofuran (THF) as the reaction solvent, The traditional test for monitoring the endpoint of the hydrogenation is a gas chromatographic procedure that requires an estimated 60 min from the time a sample is taken to the point where the analysis results become available. The use of NIR spectroscopy in an on-line mode of operation allows spectra to be collected every 2 min and thereby significantly improves response time and result availability. The need for obtaining results in "real time" stems from the creation of undesired side products if the reaction is allowed to continue past the optimal endpoint. If the reaction is not stopped before these side products reach a level of approximately 0.8% (wt/wt), the batch requires additional purification at considerable time and cost. A partial least-squares model was constructed, validated, and successfully used to determine the endpoint of subsequent batches.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 50 条
  • [1] Closed-loop on-line process identification using a proportional controller
    Park, JH
    Park, HI
    Lee, IB
    CHEMICAL ENGINEERING SCIENCE, 1998, 53 (09) : 1713 - 1724
  • [2] On-line, closed-loop identification of multivariable systems
    Melo, Diogenes L.
    Friedly, John C.
    Industrial and Engineering Chemistry Research, 1992, 31 (01): : 274 - 281
  • [3] Performance of an on-line closed-loop color control system
    Pope, B
    Sweeney, J
    DISSEMINATING GRAPHIC ARTS RESEARCH INTERNATIONALLY SINCE 1948, 2000 TAGA PROCEEDINGS, 2000, : 417 - 431
  • [4] On-Line Identification of Process Models in Closed-Loop Material Testing
    Lee, S. R.
    Srinivasan, K.
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1989, 111 (02): : 172 - 179
  • [5] On-line autotuning of PID controller for desired closed-loop response
    Kula, Krzysztof S.
    2015 20TH INTERNATIONAL CONFERENCE ON METHODS AND MODELS IN AUTOMATION AND ROBOTICS (MMAR), 2015, : 707 - 711
  • [6] On-line process monitoring using NIR spectroscopy
    Miller, Keith L.
    Telecommunications Policy, 1994, 18 (08)
  • [7] A simple approach for on-line PI controller tuning using closed-loop setpoint responses
    Shamsuzzoha, Mohammad
    Skogestad, Sigurd
    Halvorsen, Ivar J.
    20TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2010, 28 : 619 - 624
  • [8] On-line closed-loop model validation and detection of abrupt parameter changes
    Huang, BA
    JOURNAL OF PROCESS CONTROL, 2001, 11 (06) : 699 - 715
  • [9] A PLS regression model using NIR spectroscopy for on-line monitoring of the biodiesel production reaction
    Killner, Mario H. M.
    Rohwedder, Jarbas J. R.
    Pasquini, Celio
    FUEL, 2011, 90 (11) : 3268 - 3273
  • [10] On-line determination and control of the water content in a continuous conversion reactor using NIR spectroscopy
    Ward, H. W.
    Sistare, Frank E.
    ANALYTICA CHIMICA ACTA, 2007, 595 (1-2) : 319 - 322