An application study of low-dose computed tomography perfusion imaging (LDCTPI) in breast cancer and breast fibroadenoma

被引:4
|
作者
Cheng, You-Gen [1 ]
Sun, Zong-Qiong [2 ]
Zhang, Hong-Xia [1 ]
Mao, Guo-Qun [1 ]
机构
[1] Tongde Hosp Zhejiang Prov, Dept Radiol, Hangzhou 310012, Zhejiang, Peoples R China
[2] Jiangnan Univ, Peoples Hosp Wuxi City 4, Dept Radiol, Affiliated Hosp, Wuxi, Jiangsu, Peoples R China
关键词
Breast cancer; breast fibroadenoma; low dose; low-dose CT perfusion imaging; quantitative imaging markers; evaluation of tumor characteristics; CT PERFUSION; MAMMOGRAPHY; PARAMETERS; PROGNOSIS; WOMEN;
D O I
10.3233/XST-18377
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
PURPOSE: To explore the characteristics of breast cancer and breast fibroadenoma using low-dose computed tomography perfusion imaging (LDCTPI) including specific perfusion parameter values, and seek the potential clinical applications in cancer prognosis assessment. MATERIALS AND METHODS: Fifty patients including 30 diagnosed with breast cancer and 20 with breast fibroadenoma, as well as 15 control subjects with normal breasts were studied prospectively using LDCTPI examinations. The acquired volumetric imaging data were used for calculation, mapping and analysis by using a body tumor perfusion protocol in the CT perfusion software to measure 4 parameters: blood flow (BF), blood volume (BV), mean transit time (MTT), and the permeability surface (PS) area product. Statistical data analysis was then performed to distinguish the difference of the 4 parameter values among normal control, breast cancer and breast fibroadenoma cases. RESULTS: The mean perfusion values of 15 normal controls were as follows: BF, 20.03 +/- 4.08 mL/100 g/min; BV, 4.53 +/- 0.95 mL/100 g; MTT, 5.90 +/- 0.82 s; and PS, 9.25 +/- 1.18 mL/100 g/min. The mean perfusion values of 30 cancer patients were as follows: BF, 56.67 +/- 6.59 mL/100 g/min; BV, 5.82 +/- 0.68 mL/100 g; MTT, 6.01 +/- 0.82 s; and PS, 24.95 +/- 5.05 mL/100 g/min. The mean perfusion values of 20 patients with breast fibroadenoma were as follows: BF, 46.24 +/- 6.65 mL/100 g/min; BV, 5.07 +/- 0.73 mL/100 g; MTT, 7.51 +/- 0.62 s; and PS, 16.73 +/- 6.48 mL/100 g/min. Comparing the 3 groups, differences were all statistically significant for BF, BV, MTT and PS values (p < 0.05, respectively); The BF, BV, PS values were highest in group of cancer patients, while the MTT value was highest in group of patients diagnosed with breast fibroadenoma. CONCLUSION: Breast CT perfusion imaging is a promising functional imaging technology in breast cancer diagnosis, which can provide valuable quantitative imaging markers to assist evaluation of breast tumors.
引用
收藏
页码:681 / 690
页数:10
相关论文
共 50 条
  • [21] Screening for Lung Cancer With Low-Dose Computed Tomography
    Miller, Anthony B.
    ONCOLOGIST, 2013, 18 (08): : 897 - 899
  • [22] Lung cancer screening with low-dose computed tomography
    Luis M. Seijo Maceiras
    memo - Magazine of European Medical Oncology, 2014, 7 (1) : 6 - 9
  • [23] Screening for Lung Cancer With Low-Dose Computed Tomography
    Brodersen, John
    Rasmussen, Jakob Fraes
    Heleno, Bruno
    ANNALS OF INTERNAL MEDICINE, 2014, 160 (03) : 211 - 211
  • [24] Machine Learning Models That Integrate Tumor Texture and Perfusion Characteristics Using Low-Dose Breast Computed Tomography Are Promising for Predicting Histological Biomarkers and Treatment Failure in Breast Cancer Patients
    Park, Hyun-Soo
    Lee, Kwang-sig
    Seo, Bo-Kyoung
    Kim, Eun-Sil
    Cho, Kyu-Ran
    Woo, Ok-Hee
    Song, Sung-Eun
    Lee, Ji-Young
    Cha, Jaehyung
    CANCERS, 2021, 13 (23)
  • [25] Deep learning reconstruction computed tomography with low-dose imaging
    Tamura, Akio
    Ota, Yoshitaka
    Yoshioka, Kunihiro
    PEDIATRIC RADIOLOGY, 2024, 54 (08) : 1410 - 1410
  • [26] Study of Low-Dose Capecitabine Monotherapy for Metastatic Breast Cancer
    Taguchi, Tetsuya
    Nakayama, Takahiro
    Masuda, Norikazu
    Yoshidome, Katsuhide
    Akagi, Kenzou
    Nishida, Yukihiro
    Yoshikawa, Yukinobu
    Ogino, Nobuo
    Abe, Chigusa
    Sakamoto, Junichi
    Noguchi, Shinzaburo
    CHEMOTHERAPY, 2010, 56 (02) : 166 - 170
  • [27] Computed tomography for imaging the breast
    Boone, John M.
    Kwan, Alex L. C.
    Yang, Kai
    Burkett, George W.
    Lindfors, Karen K.
    Nelson, Thomas R.
    JOURNAL OF MAMMARY GLAND BIOLOGY AND NEOPLASIA, 2006, 11 (02) : 103 - 111
  • [28] Computed Tomography for Imaging the Breast
    John M. Boone
    Alex L. C. Kwan
    Kai Yang
    George W. Burkett
    Karen K. Lindfors
    Thomas R. Nelson
    Journal of Mammary Gland Biology and Neoplasia, 2006, 11 : 103 - 111
  • [29] Low-Dose Computed Tomography for Lung Cancer Screening: The Protocol and The Dose
    McDermott, Shaunagh
    Kaira, Mannudeep K.
    SEMINARS IN ROENTGENOLOGY, 2017, 52 (03) : 132 - 136
  • [30] Opportunistic Breast Density Assessment in Women Receiving Low-dose Chest Computed Tomography Screening
    Chen, Jeon-Hor
    Chan, Siwa
    Lu, Nan-Han
    Li, Yifan
    Tsai, Yu Chieh
    Huang, Po Yun
    Chang, Chia-Ju
    Su, Min-Ying
    ACADEMIC RADIOLOGY, 2016, 23 (09) : 1154 - 1161